Deye MS-GS215-2H3
This datasheet provides complete technical specifications for the MS-GS215-2H3, MS-TS500-2, and MS-BCP500-2. Key specifications include 215 kWh energy capacity, IP54 protection, and a maximum efficiency of 97.6%. Designed for commercial and industrial energy storage applications in the United Arab Emirates region.
Technical Specifications
| Parameter | MS-TS500-2 | MS-GS215-2H3 | MS-BCP500-2 | MS-EMS |
|---|---|---|---|---|
| Battery System Specifications | ||||
| AC Output Power (kW) | 100 | 500 | 500 | N/A |
| AC Output Frequency and Voltage | 50/60Hz; 380/400Vac | 50Hz | 50Hz | N/A |
| Grid Type | 3L/N/PE | N/A | N/A | N/A |
| Battery Operating Voltage (Vdc) | 660-864 | N/A | N/A | N/A |
| Energy (kWh) | 215 | N/A | N/A | N/A |
| Dimension (W×D×H, mm) | 1865×1000×2500 | 1000×1000×2250 | 1000×1000×2250 | N/A |
| Weight Approx. (kg) | 2900 | <700 | <650 | N/A |
| Max. RTE | 88% | N/A | N/A | N/A |
| System Communication | ETH/4G | N/A | N/A | N/A |
| System Operating Temperature Range (°C) | -20 to 50 (>45 Derating) | -20°C - 55°C | -20°C - 55°C | N/A |
| Max. Working Altitude (m) | <3000 | |||
| IP Rating of Enclosure | IP54 | |||
| Anti-Corrosion Grade | ≤C5 | N/A | N/A | N/A |
| System Certification | UN3536, IEC61000, IEC62477, IEC60730 | N/A | N/A | N/A |
| Converter Specification | ||||
| AC Output Rated Current (A) | 152 | N/A | N/A | N/A |
| Max. AC Output Current (A) | 167 | N/A | N/A | N/A |
| Max. Number of Parallel (off-grid) | 10 pcs | N/A | N/A | N/A |
| Peak Power | 1.1 times of rated power | N/A | N/A | N/A |
| Power Factor | -1 ~ 1 | N/A | N/A | N/A |
| THD | <3% | N/A | N/A | N/A |
| DC Injection Current | <0.5In | N/A | N/A | N/A |
| Display | LCD | N/A | N/A | N/A |
| Relative Humidity | 15% ~ 85% (No Condensing) | N/A | N/A | N/A |
| Dimension (W×D×H, mm) | 506×772×310 | N/A | N/A | N/A |
| Communication | CAN, RS485, ETH | N/A | N/A | N/A |
| Overvoltage Protection | DC Type II / AC Type II | N/A | N/A | N/A |
| Protection Level | Class 1 | N/A | N/A | N/A |
| Grid Regulation | EN50549, AS4777.2, CEI 0-21, CEI-016, NRS097 | N/A | N/A | N/A |
| Max. Efficiency | 97.6% | N/A | N/A | N/A |
| PV Specification | ||||
| Out Rated Power (kW) | 150 (dc) | N/A | N/A | N/A |
| Max. Input Voltage (V) | 1000 | N/A | N/A | N/A |
| Start Voltage (V) | 200 | N/A | N/A | N/A |
| MPPT Voltage Range (V) | 180-650 | N/A | N/A | N/A |
| Full Load Voltage Range (V) | 450-650 | N/A | N/A | N/A |
| Number of MPPT | 8 pcs | N/A | N/A | N/A |
| MPPT Max. Current / Short Current (A) | 40 / 60 | N/A | N/A | N/A |
| Dimension (W×D×H, mm) | 440×610×178 | N/A | N/A | N/A |
| Weight Approx. (kg) | 32 | N/A | N/A | N/A |
| System | ||||
| Configuration | EMS controller, lightning protection module, switch power supply, UPS module, switch | |||
| Single Point Access Capacity | Energy storage: ≤ 3.44MWp Photovoltaic: ≤ 1.6MWp | |||
| Function | Basic functions: peak valley arbitrage, anti backflow, main transformer overload protection, load tracking, demand control, backup power function, phase separation control, SOC balancing, Deye Cloud monitoring. Advanced features: load forecasting, production planning, electricity price planning, optimal economic curve | |||
| Communication | ||||
| Ethernet (5 channels) | 10 / 100 / 1000 Mbps | |||
| Fiber Optic Port (2 channels) | 1Gbps | |||
| USB (2 channels) | Host | |||
| CAN (3 channels) | Isolation, with 2 channels supporting CAN-FD | |||
| RS485 (8 channels) | Isolation | |||
| RS232 (3 channels) | 2 isolated channels, 1 non isolated debugging channel (DB9 socket) | |||
| TF Card (1 channel) | Standard TF card holder | |||
| LVDS (1 channel) | The physical interface is DVI (including 1 USB for touch) | |||
| M.2 Interfaces (1 channel) | PCIe2.0 X1, Scalable SSD (standard 1TB) | |||
| DI (17 channels) | Optocoupler isolation | |||
| DO (8 channels) | Relay isolation | |||
| WLAN | 802.11 b / a / g / n, HT 20 / 40, 2.4 GHz 5 GHz | |||
| Power Supply | ||||
| Communication Input | 220Vac | |||
| DC IN | 24Vdc | |||
| UPS Backup Power | 24Vdc | |||
| Consumption | Max 25W | |||
| Environmental Parameters | ||||
| Operation Temperature | -15°C ~ +50°C | |||
| Storage Temperature | -15°C ~ +50°C | |||
| Working Humidity | 5% ~ 95% | |||
| Max. Working Altitude (m) | ≤3000m | |||
| IP Rating of Enclosure | IP54 | |||
| Anti-Corrosion Grade | ≥C4 | |||
| Mechanical Parameters | ||||
| Dimension (W × D × H, mm) | 488 × 188 × 588 | |||
| Weight Appr. (kg) | ≤24.5kg | |||
| Installation Location | Indoor or outdoor, wall-mounted | |||
| Box Material | Metal | |||
Note: Specifications are based on the official Deye SUN-18/20/21K-G04-LV datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Key Features & Technical Highlights
Dual MPPT for LV Three-Phase Systems
The SUN-18/20/21K-G04-LV series incorporates two independent MPPT trackers optimized for low-voltage three-phase grid connections. Each MPPT supports 3 strings (3+3 configuration), enabling flexible array designs across different roof orientations or partial shading scenarios.
With a wide MPPT voltage range of 200V to 700V and rated DC bus voltage of 350V, the inverter accommodates various string configurations while maintaining peak efficiency on LV 127V/220V and 133V/230V networks.
Industry-Leading Efficiency
Maximum conversion efficiency of 98.6% combined with MPPT tracking efficiency exceeding 99% minimizes energy losses throughout the system lifetime. This high efficiency directly translates to improved energy yield and faster return on investment for commercial installations.
Comprehensive Protection Suite
- DC Side: Reverse polarity protection, surge protection (Type II), integrated DC switch
- AC Side: Overcurrent, overvoltage, and short circuit protection with Type II surge protection
- System Safety: Anti-islanding, residual current detection, insulation impedance monitoring
- Thermal Management: Intelligent air cooling with automatic derating above 45°C
- Optional: Arc Fault Circuit Interrupter (AFCI) for enhanced fire safety
Smart Monitoring & Grid Support
Standard RS485/RS232 communication ports with optional GPRS, WiFi, Bluetooth, 4G, and LAN connectivity enable comprehensive remote monitoring. Zero Export and VSG (Virtual Synchronous Generator) applications provide advanced grid interaction capabilities for self-consumption optimization and grid stability support.
Applications & Use Cases
Typical Applications
- Commercial rooftops
- Warehouses and logistics centers
- Industrial plants
- Office buildings
- Shopping malls
Installation Notes (United Arab Emirates)
Climate Suitability: Hot desert climate with temperatures reaching 50°C in summer. High humidity in coastal areas (up to 100% RH). Frequent sandstorms and dust.
Regulatory: Coordinate with DEWA, ADDC, ESMA for grid connection requirements.
- Ensure proper ventilation to maintain optimal operating temperatures.
- Coordinate with local utilities for grid connection and compliance.
- Consider additional surge protection in areas prone to electrical disturbances.
Model Selection Guide
Selecting between the SUN-18K, SUN-20K, and SUN-21K-G04-LV depends on:
- Array Size: Match PV array DC capacity to inverter input power (DC/AC ratio typically 1.1–1.3×)
- Available LV Service Capacity: Verify main breaker and feeder ampacity can accommodate inverter output current
- Load Profile: Size to typical daytime load for maximum self-consumption in zero-export applications
- Expansion Plans: Consider future load growth when selecting inverter capacity
| Model | AC Output | Max PV Input | Typical Array Size* |
|---|---|---|---|
| SUN-18K-G04-LV | 18 kW | 23.4 kW | 19.8 – 23.4 kWp |
| SUN-20K-G04-LV | 20 kW | 26 kW | 22 – 26 kWp |
| SUN-21K-G04-LV | 21 kW | 27.3 kW | 23.1 – 27.3 kWp |
*Based on DC/AC ratio of 1.1–1.3× for optimal energy harvest in high-irradiance locations.
Frequently Asked Questions
What is the maximum efficiency of the MS-GS215-2H3?
The MS-GS215-2H3 achieves a maximum efficiency of 97.6%, making it highly efficient for energy storage applications.
What grid voltage does the MS-GS215-2H3 support?
The MS-GS215-2H3 supports a grid voltage of 380/400Vac at a frequency of 50/60Hz, suitable for various grid configurations.
What is the cycle life of the MS-GS215-2H3?
The cycle life of the MS-GS215-2H3 is not explicitly stated in the specifications provided.
What is the warranty for the MS-GS215-2H3?
The MS-GS215-2H3 comes with a 5-Year Manufacturer Warranty, ensuring reliability and support.
Is the MS-GS215-2H3 suitable for outdoor installation?
Yes, the MS-GS215-2H3 is suitable for both indoor and outdoor installation, with an IP54 rating for protection.
What protection features does the MS-GS215-2H3 include?
The MS-GS215-2H3 includes overvoltage protection (DC Type II / AC Type II) and has a protection level of Class 1.
Can the MS-GS215-2H3 be used in United Arab Emirates?
Yes, the MS-GS215-2H3 can be used in United Arab Emirates, as it complies with relevant grid regulations like EN50549 and AS4777.2.
What monitoring options are available for the MS-GS215-2H3?
The MS-GS215-2H3 offers monitoring options via Deye Cloud, providing advanced features like load forecasting and production planning.