| Parameter | SUN-3K-SG05LP3-EU-SM2 | SUN-4K-SG05LP3-EU-SM2 | SUN-5K-SG05LP3-EU-SM2 | SUN-6K-SG05LP3-EU-SM2 | SUN-8K-SG05LP3-EU-SM2 | SUN-10K-SG05LP3-EU-SM2 | SUN-12K-SG05LP3-EU-SM2 |
|---|---|---|---|---|---|---|---|
| PV String Input Data | |||||||
| Max PV Array Power | 6000 W | 8000 W | 10000 W | 12000 W | 16000 W | 20000 W | 24000 W |
| Max PV Input Power | 4800 W | 6400 W | 8000 W | 9600 W | 12800 W | 16000 W | 19200 W |
| Max PV Input / Array Open Circuit Voltage | 800 V | ||||||
| Max PV Input Current | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 26+26 A | 26+26 A | 26+26 A |
| MPPT Efficiency | >99% | ||||||
| MPPT Voltage Range | 200 V – 650 V | ||||||
| MPPT Voltage Range at Full Load | 250 V – 650 V | 250 V – 650 V | 250 V – 650 V | 250 V – 650 V | 350 V – 650 V | 350 V – 650 V | 350 V – 650 V |
| Number of MPP Trackers | 2 | ||||||
| PV Operating Voltage Range | — | — | — | — | — | 160 V – 800 V | 160 V – 800 V |
| Start-up Voltage | 160 V | ||||||
| Max PV Short-Circuit Current | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 39+39 A | 39+39 A | 39+39 A |
| MPPT Nominal Voltage | 550 V | ||||||
| Electrical / AC Output Data | |||||||
| European Efficiency | 97.0% | ||||||
| Max AC Apparent Power | 3300 VA | 4400 VA | 5500 VA | 6600 VA | 8800 VA | 11000 VA | 13200 VA |
| Max Efficiency | 97.6% | ||||||
| Peak / Surge Power (W) | 2 times of rated power, 10s | ||||||
| Rated AC Power | 3000 W | 4000 W | 5000 W | 6000 W | 8000 W | 10000 W | 12000 W |
| AC Frequency Range | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 60Hz/55Hz-65Hz | 60Hz/55Hz-65Hz | 60Hz/55Hz-65Hz |
| AC Grid Connection Type | 3L+N+PE | ||||||
| Max Parallel Units | 10 | ||||||
| Nominal AC Voltage Range | 220/380V,230/400V 0.85Un-1.1Un | ||||||
| Output Voltage Range | 220/380V,230/400V 0.85Un-1.1Un 3L+N+PE | ||||||
| Phase | Three-phase | ||||||
| Rated AC Output Current | 4.6/4.4 A | 6.1/5.8 A | 7.6/7.3 A | 9.1/8.7 A | 12.2/11.6 A | 15.2/14.5 A | 18.2/17.4 A |
| THD / THDi | <3% (of nominal power) | ||||||
| Adjustable Power Factor Range | 0.8 leading to 0.8 lagging | ||||||
| Max AC Output Current | 5/4.8 A | 6.7/6.4 A | 8.4/8 A | 10/9.6 A | 13.4/12.8 A | 16.7/16 A | 20/19.2 A |
| Max Continuous AC Pass-Through | 45 A | ||||||
| Topology | Non-Isolated (solar), Isolated (battery) | ||||||
| Unbalanced Output | 100% | ||||||
| Max Inverter Backfeed Current | 0 A | ||||||
| Battery Data | |||||||
| Battery Voltage Range | 40 V – 60 V | ||||||
| Max Charge Current | 70 A | 95 A | 120 A | 135 A | 190 A | 210 A | 240 A |
| Max Charge/Discharge Current | 70 A | 95 A | 120 A | 135 A | 190 A | 210 A | 240 A |
| Max Discharge Current | 70 A | 95 A | 120 A | 135 A | 190 A | 210 A | 240 A |
| Supported Battery Type | Lead-acid or Lithium-ion | ||||||
| Number of Battery Inputs | 1 | ||||||
| Protection Features | |||||||
| IP Rating | IP 65 | ||||||
| AC/DC Surge Protection | TYPE II(DC), TYPE II(AC) | ||||||
| DC Reverse Polarity Protection | — | — | — | — | — | Yes | Yes |
| Grid Connection Standards | IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097, RD4105140, UNE 217002, | ||||||
| Insulation Resistance Monitoring | — | — | — | — | — | Yes | Yes |
| Over-Temperature / Thermal Protection | Yes | ||||||
| Overvoltage Category | OVC II(DC), OVC III(AC) | ||||||
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||||
| Mechanical Data | |||||||
| Cooling Method | Intelligent Air Cooling | ||||||
| Operating Conditions | |||||||
| Max Altitude | 3000m | ||||||
| Noise Level | ≤55 dB | ||||||
| Operating Temperature | -40 to +60℃, >45℃ Derating °C | ||||||
| Relative Humidity | 0-100% | ||||||
| Communication | |||||||
| Communication Interface | WIFI,RS485,CAN | ||||||
| Display | LCD | ||||||
Note: Specifications are based on the official Deye SUN-3/4/5/6/8/10/12K-SG05LP3-EU-SM2 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in UAE
| Market | UAE |
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Delivery & installation coverage | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in UAE that is DEWA, ADDC, SEWA. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 70A Charging: High power charging
- 48V Low Voltage: Transformer isolation design
- 100% Unbalanced: 50% rated power per phase
- 10 Units Parallel: Scale up to 30kW
- AC Coupling: Retrofit existing systems
- 6 Time Periods: Advanced battery management
- 95A Charging: High power charging
- 120A Charging: High power charging
- 135A Charging: High power charging
- 190A Charging: High power charging
- 210A Charging: High power charging
- 240A Charging: High power charging
Frequently Asked Questions
Is the DEYE SUN-3K-SG05LP3-EU-SM2 suitable for the Middle East climate?
Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
What is transformer isolation?
Transformer isolation provides galvanic separation between the battery and AC side, enhancing safety and allowing the use of various battery types including lead-acid and lithium-ion.
What does 100% unbalanced output mean?
It means each phase can deliver up to 50% of the rated power independently, providing flexibility for unbalanced loads across the three phases.