| Parameter | SUN-3K-G06P3-EU-AM2-P1 | SUN-4K-G06P3-EU-AM2-P1 | SUN-5K-G06P3-EU-AM2-P1 | SUN-6K-G06P3-EU-AM2-P1 | SUN-7K-G06P3-EU-AM2-P1 | SUN-8K-G06P3-EU-AM2-P1 | SUN-9K-G06P3-EU-AM2-P1 | SUN-10K-G06P3-EU-AM2-P1 | SUN-12K-G06P3-EU-AM2-P1 | SUN-15K-G06P3-EU-AM2-P1 |
|---|---|---|---|---|---|---|---|---|---|---|
| PV String Input Data | ||||||||||
| Max PV Array Power | — | — | — | — | — | — | — | 20000 W | 24000 W | — |
| Max PV Input Power | 4.5 kW | 6 kW | 7.5 kW | 9 kW | 10.5 kW | 12 kW | 13.5 kW | 15 kW | 18 kW | 22.5 kW |
| Max PV / DC Voltage | 1100 V | |||||||||
| Max PV Input / Array Open Circuit Voltage | 1100 V | |||||||||
| Max PV Input Current | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 20+26 A | 20+26 A | 20+26 A |
| MPPT Efficiency | >99% | |||||||||
| MPPT Voltage Range | 120 V – 1000 V | |||||||||
| MPPT Voltage Range at Full Load | — | — | — | — | — | — | — | 350 V – 650 V | 350 V – 650 V | — |
| Number of MPP Trackers | 2 | |||||||||
| PV Operating Voltage Range | — | — | — | — | — | — | — | 160 V – 800 V | 160 V – 800 V | — |
| Start-up Voltage | 140 V | |||||||||
| Max PV Short-Circuit Current | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 30+39 A | 30+39 A | 30+39 A |
| MPPT Nominal Voltage | 600 V | |||||||||
| Electrical / AC Output Data | ||||||||||
| European Efficiency | 97.5% | 97.5% | 97.6% | 97.6% | 97.8% | 97.8% | 97.8% | 97.8% | 97.8% | 98.0% |
| Max AC Apparent Power | 3.3 kVA | 4.4 kVA | 5.5 kVA | 6.6 kVA | 7.7 kVA | 8.8 kVA | 9.9 kVA | 11000 VA | 13200 VA | 16.5 kVA |
| Max Efficiency | 98.1% | 98.1% | 98.2% | 98.2% | 98.3% | 98.3% | 98.3% | 98.3% | 98.3% | 98.5% |
| Rated AC Power | 3 kW | 4 kW | 5 kW | 6 kW | 7 kW | 8 kW | 9 kW | 10 kW | 12 kW | 15 kW |
| AC Grid Connection Type | 3L/N/PE | |||||||||
| Grid / AC Frequency | 50/45-55, 60/55-65 Hz | |||||||||
| Nominal AC Voltage | 220/380V, 230/400V | |||||||||
| Output Voltage Range | 220/380V, 230/400V 0.85Un-1.1Un | |||||||||
| Phase | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase | Three-phase | C current =5.002A | Three-phase |
| Rated AC Output Current | 4.6/4.4 A | 6.1/5.8 A | 7.6/7.3 A | 9.1/8.7 A | 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A | 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A | 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A | 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A | 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A | 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A |
| THD / THDi | <3% | |||||||||
| Adjustable Power Factor Range | 0.8 leading to 0.8 lagging | |||||||||
| Max AC Output Current | 5/4.8 A | 6.7/6.4 A | 8.4/8 A | 10/9.6 A | 11.7/11.2 13.4/12.8 A | 11.7/11.2 13.4/12.8 A | 15/14.4 A | 16.7/16 A | 20/19.2 A | 25/24 A |
| Max Continuous AC Pass-Through | — | — | — | — | — | — | — | 45 A | 45 A | — |
| Topology | Non-Isolated | |||||||||
| Max Inverter Backfeed Current | — | — | — | — | — | — | — | — | 0 A | — |
| Battery Data | ||||||||||
| Max Charge Current | — | — | — | — | — | — | — | 210 A | 240 A | — |
| Max Discharge Current | — | — | — | — | — | — | — | 210 A | 240 A | — |
| Number of Battery Inputs | — | — | — | — | — | — | — | 1 | 1 | — |
| Protection Features | ||||||||||
| IP Rating | IP65 | |||||||||
| AC Short-Circuit Protection | — | yes | — | — | — | — | — | — | — | — |
| AC/DC Surge Protection | TYPE II(DC), TYPE II(AC) | |||||||||
| Anti-Islanding Protection | Yes | |||||||||
| DC Component Monitoring | — | yes | — | — | — | — | — | — | — | — |
| DC Reverse Polarity Protection | — | yes | — | — | — | — | — | Yes | yes | — |
| DC Switch | — | yes | — | — | — | — | — | — | yes | — |
| Grid Connection Standards | IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002, | |||||||||
| Grid Monitoring | Yes | |||||||||
| Ground Fault Monitoring | Yes | |||||||||
| Insulation Resistance Monitoring | — | yes | — | — | — | — | — | Yes | Yes | — |
| Over-Current Protection | — | yes | — | — | — | — | — | — | yes | — |
| Over-Temperature / Thermal Protection | Yes | |||||||||
| Over-Voltage Protection | — | yes | — | — | — | — | — | — | — | — |
| Overload Protection | Yes | |||||||||
| Overvoltage Category | OVC II(DC), OVC III(AC) | |||||||||
| Residual Current Monitoring Unit | Yes | |||||||||
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||||
| Surge Protection Level | — | TYPE II(AC) | — | — | — | — | — | — | TYPE II(AC) | — |
| Mechanical Data | ||||||||||
| Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Intelligent Air Cooling |
| Cooling Method | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Intelligentaircooling | Intelligentaircooling | Intelligentaircooling |
| Operating Conditions | ||||||||||
| Max Altitude | 4000 m | |||||||||
| Noise Level | <45 dB | |||||||||
| Operating Temperature | -25 to 60 °C | |||||||||
| Relative Humidity | 0-100% | |||||||||
| Communication | ||||||||||
| Communication Interface | RS485/RS232 | |||||||||
| Monitoring Module | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||||||||
Note: Specifications are based on the official Deye SUN-3/4/5/6/7/8/9/10/12/15K-G06P3-EU-AM2-P1 datasheet. Values may be subject to change; always verify against the latest manufacturer documentation before system design and procurement.
Availability & grid compliance in Kuwait
| Market | Kuwait |
| Grid authority / regulator | MEW Kuwait |
| Quotation currency | KWD |
| Support hours timezone | Asia/Kuwait |
| Delivery & installation coverage | Kuwait City, Hawalli, Salmiya |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Kuwait that is MEW Kuwait. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 98.5% Efficiency: Maximum energy conversion
- Dual MPPT: Two independent trackers
- 1100V PV Input: High voltage compatibility
- Zero Export: Grid export management
- VSG Support: Virtual Synchronous Generator
- Smart Monitoring: Optional string monitoring
Frequently Asked Questions
Is the DEYE SUN-3K-G06P3-EU-AM2-P1 suitable for the Middle East climate?
Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
What makes this the P1 version?
The P1 version features enhanced specifications and is designed for optimal performance across a wide range of applications, with support for both residential and commercial installations.
What is the maximum PV input?
The SUN-3K supports 4.5kW PV input, while the SUN-15K supports up to 22.5kW, allowing for high DC/AC ratios and maximum energy harvest.