Technical Specifications
| Parameter | DEYE-MC-L430-2H3 |
|---|---|
| Additional Specifications | |
| Active Balancing Function | No |
| Charge and discharge rate | 0.5P |
| Nominal AC Voltage | 380/400V 3P+N+PE |
| Anticorrosion grade | C4M (C5M is optional) |
| Fire Suppression | Aerosol, Water |
| Charge and discharge | 0.5P |
| DC Voltage Range | 648-876 Vdc |
| Max Parallel Cabinets | 8 |
| DC Fast Charge | 420 kW |
| Weight | ≤5000kg |
| System parameter Operating Temperature | -25℃~ +55℃ |
| PV String Input Data | |
| Maximum Power (Pmax) | 220kW ( 1.1 times of rated power ) |
| Nominal DC Voltage | 768Vd.c. |
| Battery Data | |
| Nominal Capacity | 280Ah |
| Battery Energy Capacity | 430.08kWh |
| Battery Type / Chemistry | LiFePO₄ |
| Electrical / AC Output Data | |
| Power Factor | -1 ~ 1 |
| Frequency / Frequency Range | 50 / 60Hz |
| Rated AC Power | 200kW |
| Grid Switching / Transfer Time | 10 ms |
| Communication | |
| Communication Interface | RS485, Modbus TCP, DIDO |
| Protection Features | |
| IP Rating | IP55 (Battery compartment; Chiller |
| Mechanical Data | |
| Type of cooling | Liquid cooling |
| Cooling Method | Liquid cooling |
| Operating Conditions | |
| Operating Temperature | -25°C ~ +55°C |
| Max Altitude | ≤2000m |
| Relative Humidity | 0 ~ 95% |
| Noise Level | ≤75dBA (70dBA solution is optional) |
| Storage Temperature Range | -30℃~ +60℃ |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 430kWh Energy: High-capacity storage
- Smart Cloud: 24/7 O&M, custom algorithms
- 5-Level Safety: Fire/explosion protection
- 8 Cabinets Parallel: Scalable expansion
- 420kW DC Charge: EV charging support
- Multi-Region: AS, AF, AU, EU, LATAM
Frequently Asked Questions
Is the DEYE MC-L430-2H3 Series suitable for hot climates like the Gulf?
Yes. The MC-L430-2H3 Series uses LiFePO4 chemistry with a BMS and thermal management designed to operate safely in the high ambient temperatures common across the Middle East and Africa.
What regions is this certified for?
The MC-L430-2H3 is certified for Asia, Africa, Australia, Europe, and Latin America markets, making it a versatile solution for global C&I deployments.
What applications does it support?
It supports diverse applications including EV charging expansion, peak-valley energy optimization, virtual power plant readiness, and off-grid use for islands and base stations.