Deye GB-A
A slim 409.6 V home battery just 200 mm deep, built from 2 kWh modules for 4 to 16 kWh, IP65-sealed and able to charge at -20 degrees C.
Technical Specifications
| Parameter | DEYE-GB-A |
|---|---|
| Battery Data | |
| Energy | 2 kWh |
| Usable Energy | 3.6 kWh |
| Module Energy | 2 kWh |
| System Energy | 4-16 kWh |
| Max. Capacity | 16 kWh |
| Nominal Voltage | 51.2 V |
| Module Nominal Voltage | 51.2 V |
| System Nominal Voltage | 409.6 V |
| Operating Voltage | 358.4-460.8 V |
| Rated Capacity | 39.1 Ah |
| Module Capacity | 39.1 Ah |
| Cell Chemistry | LiFePO4 |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70% |
| Recommended Depth of Discharge | 90% |
| Max. Charge Current | 28 A |
| Max. Discharge Current | 37 A |
| Max. Charge/Discharge Current | 37 A |
| Recommended Charge/Discharge Current | 28 A |
| Modules in Series | 2-8 |
| Min. Battery Module Quantity | 2 |
| Battery Module Models | GB-A-PACK4, GB-A-PACK6 |
| Warranty (Years) | 10 |
| Mechanical & Interface | |
| Communication Ports | CAN2.0, RS485 |
| Dimensions | 700 x 1575 x 200 mm |
| Additional Notes | Charge power 2.5/6.25/10 kW and discharge power 3.3/8.2/10 kW per config |
| Status Indicator | Yellow: Battery High Voltage Power On; Red: Battery System Alarm |
| Weight | 62-180 kg |
| Environment & Protection | |
| Altitude | <2000 m |
| Charge Temperature | -20 to 55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-95% |
| Installation Location | Floor-Mounted |
| Enclosure IP Rating | IP65 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge/Discharge: -20 to 55 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Grows 2 kWh at a time: Two to eight 2 kWh, 39.1 Ah modules build systems of 4 to 16 kWh at 409.6 V nominal.
- Up to 10 kW both ways: Charge power of 2.5, 6.25 or 10 kW and discharge of 3.3, 8.2 or 10 kW depending on configuration.
- Charges in freezing cold: Charges and discharges across -20 to 55 degrees C with no heating precondition.
- A 200 mm slim IP65 shell: The 700 x 1575 x 200 mm floor-standing housing is sealed to IP65 for dusty or damp spots.
- Speaks to hybrid inverters: CAN2.0 and RS485 ports pair the pack with high-voltage hybrid inverters.
- Ten-year peace of mind: More than 6,000 LiFePO4 cycles to 70% capacity, wrapped in a 10-year warranty.
Frequently Asked Questions
How slim is the GB-A really?
The housing measures 700 x 1575 x 200 mm, so it stands only 200 mm off the wall while weighing 62 to 180 kg depending on module count.
What sizes can I build with GB-A modules?
Each module carries 2 kWh; stacks of two to eight span 4 to 16 kWh, with GB-A-PACK4 and GB-A-PACK6 as the named module builds and 16 kWh as the ceiling.
Can the GB-A charge in freezing weather?
Yes; both charge and discharge are rated from -20 to 55 degrees C, so winter operation needs no special preparation.
How much power can a GB-A system deliver?
Discharge power is 3.3, 8.2 or 10 kW by configuration, with charge power of 2.5, 6.25 or 10 kW to match.
Which inverter class does the GB-A require?
A high-voltage one: the system is nominally 409.6 V and operates between 358.4 and 460.8 V, communicating over CAN2.0 or RS485.