Deye GE-F120-2H2/AU
120kWh C&I all-in-one ESS with 50kW PCS, integrated EMS/BMS, and aerosol fire suppression.
Technical Specifications
| Parameter | DEYE-GE-F120-2H2 | DEYE-GE-F120-AU |
|---|---|---|
| Additional Specifications | ||
| Air Flow Volume | 630m³/h | |
| DC Injection current(mA) | <0.5%ln | |
| Electric Shock Prevention | I | |
| Ingress Protection | IP20 | |
| Max Operating Pressure | 2.7Mpa | |
| Max.Current | 8.3A | |
| Max.Discharge Pressure | 2.7Mpa | |
| Max.Power | 1800W | |
| Max.Suction Pressure | 1.6Mpa | |
| Nominal Charge/Discharge Current | 100A | |
| Peak. Discharge Current | 125A | |
| Rated Frequency | 50/60Hz | |
| Rated Heating Current | 7.9A | |
| Rated Heating Power Input | 1700W | |
| Rated Voltage | AC 220V-240V | |
| Refrigerant | R134a/330g | |
| Water-proof Class | IP55 | |
| AC Output Frequency and Voltage | 50/60Hz; 220/380, 230/400Vac | |
| AC Output Rated Current (A) | 75.8 | |
| Battery Operating Voltage (V) | 500-700 | |
| Max. PV Input Current(A) | 36+36+36+36 | |
| Max. PV Input Power(W) | 65000 | |
| Max. PV Short-circuit Current(A) | 55+55+55+55 | |
| Number of Parallel (Off-gird) | 10 | |
| Peak Power(off gird) | 1.5 time of rated power, 10s | |
| Rated PV Input Voltage(Vdc) | 600 | |
| Start Up DC Voltage (Vdc) | 180 | |
| Battery Chemistry | LiFePO4 | |
| Inverter Technical Specification Max. PV Input Power | 65000 W | |
| Number of Parallel ( Off-grid ) | 10 | |
| Peak Power | 1.5 time of rated power, 10s off grid | |
| Energy Configuration | 122.8 kWh | |
| Rated Power | 50 kW | |
| Max Parallel (Off-grid) | 10 units | |
| Display | LCD | |
| Rated Cooling Current | 4.15A | |
| Rated Cooling Power Input | 900W | |
| IP Rating of Enclosure | IP55 | |
| Installation Style | Floor-Mounted | |
| Battery Module Dimension ( W X D X Hmm) | 440×570Х133 | |
| Battery Module Weight | 44 kg | |
| Dimension ( W × D X H,mm) | 1780 X 1056 X 2235 | |
| Installation Method | Floor-Mounted | |
| Charge Temperature | 0-55°C | |
| Discharge Temperature | -20°C~55°C | |
| Operating Temperature Range | Charge: 0-55/Discharge: -20~55 | |
| Operating Temperature Range(°C) | -40~60C(>45 derating) | |
| System Energy | 122.8 kWh | |
| Battery Module Energy | 5.12 kWh | |
| Dimension ( W X D X H, mm) | 527X294×894 | |
| Charging Temperature Range | 0~55 °C | |
| Communication | ||
| BMS Communication | CAN | |
| Communication Interface | CAN, RS485, WIFI, ETH | |
| Battery Data | ||
| Battery Type / Chemistry | LiFePO4(LFP) | |
| Module Energy | 5.12 kWh | |
| Cycle Life | ≥6000 ( @25℃±2℃, 0.5C / 0.5C, 70%EOL ) | |
| Round-Trip Efficiency | 89% | |
| PV String Input Data | ||
| MPPT Nominal Voltage | 51.2Vdc | |
| MPPT Efficiency | 99.9% | |
| MPPT Voltage Range | 150-850 Vdc | |
| Max. PV Short-circuit Current | 55+55+55+55 A | |
| Number of MPPT Channels | 4 | |
| Electrical Data | ||
| MPPT Voltage Range(Vdc) | 150-850 | |
| Rated PV Input Voltage | 600 Vdc | |
| Start Up DC Voltage | 180 Vdc | |
| Max. Charging /Discharging Efficiency | 97.6% | |
| Protection Features | ||
| Certifications | UN38.3, IEC 62619, IEC 61000 | |
| Grid Connection Standards | G98, G99, C10-11, UNE 217002, NBR 16149 / NBR 16150 | |
| IP Rating | IP55 | IP65 |
| Electrical / AC Output Data | ||
| Operating Voltage Range | 500 ~ 700 V | |
| Grid Type / Phase | 3L / N / PE | |
| Max Efficiency | 97.6% | |
| Max. PV Input Current | 36+36+36+36 A | |
| Power Factor | 0.8 leading to 0.8 lagging | |
| Rated AC Power | 50000 W | |
| THD / THDi | <3% | |
| Module Nominal Voltage | 51.2 V | |
| Operating Conditions | ||
| Storage Temperature (°C) | -20~45(>45 derating) | |
| Operating Temperature | -20 ~ 55 ( >43 derating ) °C | |
| Relative Humidity | 15% ~ 85% ( No Condensing ) | |
| Storage Temperature Range | 0 ~ 35 °C | |
| Humidity | 15%~85% (No condensing) | |
| Discharging Temperature Range | -20~55 °C | |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 122.8kWh Capacity: High-capacity storage
- 50kW Power: High-rate cycling
- Aerosol Fire System: Advanced fire suppression
- All-in-One: PCS, inverters, BMS, EMS
- 10 Units Parallel: Off-grid scalability
- <35°C Operation: Optimal thermal management
- LiFePO4 Chemistry: Safe and long-lasting lithium iron phosphate
- Long Cycle Life: Over 6000 cycles for years of service
- IP65 Protection: Dust and water resistant
- BMS Integration: Advanced battery management system
Frequently Asked Questions
Is the DEYE GE-F120-2H2 suitable for hot climates like the Gulf?
Yes. The GE-F120-2H2 uses LiFePO4 chemistry with a BMS and thermal management designed to operate safely in the high ambient temperatures common across the Middle East and Africa.
What makes this all-in-one?
The GE-F120-2H2 integrates PCS (Power Conversion System), inverters, BMS (Battery Management System), and EMS (Energy Management System) in a single unit, simplifying installation and operation.
Is it suitable for high-rate cycling?
Yes! The GE-F120-2H2 is specifically designed for high-rate cyclic charging and discharging scenarios, making it ideal for applications requiring frequent charge/discharge cycles.
Is the DEYE GE-F120-AU suitable for hot climates like the Gulf?
Yes. The GE-F120-AU uses LiFePO4 chemistry with a BMS and thermal management designed to operate safely in the high ambient temperatures common across the Middle East and Africa.
What is the warranty period?
This battery comes with a 10-year warranty covering manufacturing defects and capacity retention.
What inverters are compatible?
This battery is compatible with Deye hybrid inverters and can be configured for various system sizes.