Deye SUN-3-6-10K-SG05LP1-SM2/SUN-3.6K-SG05LP1-EU-SM2-P/SUN-5K-SG05LP1-EU-SM2-P/SUN-6K-SG05LP1-EU-SM2-P/SUN-7.6K-SG05LP1-EU-SM2-P/SUN-7K-SG05LP1-EU-SM2-P/SUN-8K-SG05LP1-EU-SM2-P
10kW (10000W) single-phase hybrid inverter with battery backup and 210A charging — sized for the largest homes and farms.
Technical Specifications
| Parameter | SUN-10K-SG05LP1-EU-SM2-P | DEYE-SUN-3-6-10K-SG05LP1-SM2 | SUN-3.6K-SG05LP1-EU-SM2-P | SUN-5K-SG05LP1-EU-SM2-P | SUN-6K-SG05LP1-EU-SM2-P | SUN-7.6K-SG05LP1-EU-SM2-P | SUN-7K-SG05LP1-EU-SM2-P | SUN-8K-SG05LP1-EU-SM2-P |
|---|---|---|---|---|---|---|---|---|
| Additional Specifications | ||||||||
| MPPT Voltage Range (V) | 150-425 | |||||||
| Max. PV Input Voltage (V) | 500 | |||||||
| Peak Power (off-grid) (W) | , 10s | |||||||
| Rated PV Input Voltage (V) | 370 | |||||||
| Grid Frequency | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | |||||||
| Peak Power (off-grid)(W) | 2 | |||||||
| DC Reverse Polarity Protection | Yes | |||||||
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | |||||||
| Max. AC Input/Output Current | 50/47.9 A | — | 18/17.2 A | 25/23.9 A | 30/28.7 A | 38/36.3 A | 35/33.5 A | 40/38.3 A |
| Rated AC Input/Output Current | 45.5/43.5 A | 16.4/15.7 22.8/21.8 27.3/26.1 31.9/30.5 34.6/33.1 36.4/34.8 45.5/43.5 A | 16.4/15.7 A | 22.7/21.7 A | 27.3/26.1 A | 34.5/33 A | 31.9/30.5 A | 36.4/34.8 A |
| Rated Input/Output Grid Frequency/Range | 50Hz/45Hz-55Hz 60Hz/55Hz-65Hz | |||||||
| Rated Input/Output Voltage/Range | 220/230 0.85Un-1.1Un V | |||||||
| Residual Current Detection | Yes | |||||||
| Max PV Voltage | 500 V | |||||||
| MPPT Trackers | 2 | |||||||
| PV Input Voltage Range | 125-500 V | |||||||
| Max. Three-phase Unbalanced Output Current | 22.7/21.7 A | |||||||
| Max. Output Overcurrent Protection | 70 A | |||||||
| DC Polarity Reverse Connection Protection | Yes | |||||||
| DC Terminal Insulation Impedance Monitoring | Yes | |||||||
| Operating Temperature Range | -40 to +60℃, >45℃ Derating | |||||||
| Permissible Ambient Humidity | 0-100% | |||||||
| LCD/LED Display | LCD | |||||||
| Insulation Impedance detection | Yes | |||||||
| Weight | 24.9 kg | |||||||
| PV Input Voltage Range(V) | 125-500 | |||||||
| Electrical / AC Output Data | ||||||||
| Max. AC Input/Output Apparent Power (VA) | 11000 | — | 3960 | 5500 | 6600 | 8360 | 7700 | 8800 |
| Max AC Output Current | 50/47.9 A | 50/47.9 A | 18/17.3 A | 25/24 A | 30/28.7 A | 38/36.4 A | 35/33.5 A | 40/38.3 A |
| Max. Charging Current (A) | 210 | — | — | 120 | 135 | 190 | 175 | 190 |
| Max. Discharging Current (A) | 210 | — | 90 | 120 | 135 | 190 | 175 | 190 |
| Max PV Array Power | 20000 | — | — | 10000 | — | — | — | — |
| Max. PV Input Power (W) | 16000 | — | 5760 | 8000 | 9600 | 12160 | 11200 | 12800 |
| Rated AC Input/Output Active Power (W) | 10000 | — | 3600 | 5000 | 6000 | 7600 | 7000 | 8000 |
| Rated AC Input/Output Current (A) | 45.5/43.5 | — | 16.4/15.7 | 22.8/21.8 | 27.3/26.1 | 34.6/33.1 | 31.9/30.5 | 36.4/34.8 |
| Max. Charging/Discharging Current | 210 | 210 | 90 | 120 | 135 | 190 | 175 | 190 |
| No. of Strings MPP Tracker | 2+2 | — | 1+1 | 1+1 | 1+1 | 2+2 | 2+2 | 2+2 |
| No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | — | 2/1+1 | 2/1+1 | 2/1+1 | 2/2+2 | 2/2+2 | 2/2+2 |
| European Efficiency | 96.5% | — | 96.50% | 96.50% | 96.5% | 96.50% | 96.50% | 96.5% |
| Full Load MPPT Voltage Range | 250-425 V | 250-425 V | 300-425 V | 300-425 V | 300-425 V | 200-425 V | 200-425 V | 250-425 V |
| AC Grid Connection Type | L+N+PE | |||||||
| Topology | Non-Isolated | — | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) | Non-Isolated | Non-Isolated | Non-Isolated (solar), Isolated (battery) | Non-Isolated |
| Max. AC Input/Output Apparent Power | 11000 VA | 11000 VA | 3960 VA | 5500 VA | 6600 VA | 8360 VA | 7700 VA | 8800 VA |
| Max Continuous AC Pass-Through | 50 A | 50 A | 35 A | 35 A | 40 A | 50 A | 40 A | 50 A |
| Max Efficiency | 97.6% | 97.6% | 97.60% | 97.60% | 97.6% | 97.60% | 97.60% | 97.6% |
| Max Inverter Backfeed Current | 0 | |||||||
| Adjustable Power Factor Range | 0.8 leading to 0.8 lagging | — | 0.8 leading-0.8 lagging | 0.8 leading-0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading-0.8 lagging | 0.8 leading-0.8 lagging | 0.8 leading to 0.8 lagging |
| THD / THDi | <3%(ofnominalpower) | — | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) |
| Peak / Surge Power (W) | 2 times of rated power, 10s | |||||||
| Rated AC Power | 10000 W | — | 3600 W | 5000 W | 6000 W | 7600 W | 7000 W | 8000 W |
| Max Parallel Units | 16 pcs | |||||||
| Max. Output Fault Current | 33.4 A | — | 36 A | — | — | — | — | — |
| DC Injection Current | <0.5%In | — | <0.5%ln | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
| Phase | Single-phase | Single Phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase |
| Rated Power | 3.6-10kW | |||||||
| Max. PV Access Power (W) | — | — | 7200 | — | 12000 | 15200 | 14000 | 16000 |
| Max. Output Fault Current(A) | — | — | — | 50 | 60 | 76 | 70 | 80 |
| Electrical Data | ||||||||
| Start-up Voltage (V) | 125 | |||||||
| Max. Discharging Current | 210 A | 210 A | 90 A | 120 A | 135 A | 190 A | 175 A | 190 A |
| Rated AC Input/Output Active Power | 10000 W | 10000 W | 3600 W | 5000 W | 6000 W | 7600 W | 7000 W | 8000 W |
| Euro Efficiency | 96.5% | |||||||
| Grid Regulation | IEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105'140, UNE 217002, | |||||||
| Inverter Topology | Non-Isolated | |||||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||||||
| Surge Protection Level | TYPE II(DC), TYPE II(AC) | |||||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | |||||||
| Max. AC Input/Output Current (A) | — | — | 18/17.3 | 25/24 | — | 38/36.4 | — | — |
| General Data | ||||||||
| Inverter Type | Hybrid Inverter | |||||||
| Battery Data | ||||||||
| Supported Battery Type | Lead-acid or Lithium-ion | |||||||
| Battery Voltage Range | 40-60 V | |||||||
| Max. Charging Current | 210 A | 210 A | 90 A | 120 A | 135 A | 190 A | 175 A | 190 A |
| Number of Battery Inputs | 1 | |||||||
| Max Charge Current | 210 A | — | 90 A | 120 A | 135 A | 190 A | 175 A | 190 A |
| Communication | ||||||||
| Communication Interface | RS485/RS232/CAN | RS485/RS232/CAN | RS232, RS485, CAN | RS232, RS485, CAN | RS232, RS485, CAN | WIFI,RS485,CAN | RS232, RS485, CAN | RS232, RS485, CAN |
| Monitoring Module | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||||||
| Display | Colorful Touch LCD | |||||||
| Protection Features | ||||||||
| Grid Connection Standards | IEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105'140, UNE 217002, | — | IECUNE61727,IEC217002,OVE-Richtlinie62116,CEI0-21,ENR25,G99,VDE-AR-N50549,NRS097,RD4105140, | IECUNE61727,IEC217002,OVE-Richtlinie62116,CEI0-21,ENR25,G99,VDE-AR-N50549,NRS097,RD4105140, | IEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105'140, UNE 217002, | IEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105140, UNE 217002, | IECUNE61727,IEC217002,OVE-Richtlinie62116,CEI0-21,ENR25,G99,VDE-AR-N50549,NRS097,RD4105140, | IEC 61727, IECOVE-Richtlinie62116,CEI0-21,R25,ENG98,50549,G99,NRSVDE-AR-N097,RD4105'140, UNE 217002, |
| Overvoltage Category | OVCII(DC),OVCIII(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) |
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||
| AC/DC Surge Protection | TYPEII(DC),TYPEII(AC) | — | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) | TYPE II(DC), TYPE II(AC) |
| Over-Temperature / Thermal Protection | Yes | |||||||
| IP Rating | IP65 | |||||||
| PV String Input Data | ||||||||
| MPPT Efficiency | >99% | |||||||
| MPPT Voltage Range | 150-425 V | |||||||
| Max PV Short-Circuit Current | 48+48 A | 48+48 A | 17+17 A | 17+17 A | 27+27 A | 34+34 A | 34+34 A | 48+48 A |
| Max PV Input Current | 32+32 A | 32+32 A | 13+13 A | 13+13 A | 18+18 A | 26+26 A | 26+26 A | 32+32 A |
| Max. PV Access Power | 20000 W | 20000 W | 7200 W | 10000 W | 12000 W | 15200 W | 14000 W | 16000 W |
| Max PV Input Power | 16000 W | 16000 W | 5760 W | 8000 W | 9600 W | 12160 W | 11200 W | 12800 W |
| Max. PV Input Voltage | 500 V | |||||||
| Rated PV Input Voltage | 370 V | |||||||
| Start-up Voltage | 125 V | |||||||
| Mechanical Data | ||||||||
| Cooling Method | Intelligent air cooling | — | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling |
| Ingress Protection(IP) Rating | IP65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 |
| Cooling | Intelligent Air Cooling | |||||||
| Type of Cooling | Intelligent Air Cooling | |||||||
| Operating Conditions | ||||||||
| Noise Level | <30 dB | |||||||
| Operating Temperature | -40 to 60 °C | -25 to +60 °C | -40 to 60 °C | -40 to 60 °C | -40 to 60 °C | -40 to 60 °C | -40 to 60 °C | -40 to 60 °C |
| Relative Humidity | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
| Max Altitude | 2000 m | |||||||
| Operating Environment | ||||||||
| Noise | <45 dB | <45 dB | <45 dB | <45 dB | <45 dB | <45 dB | <45 dB | <45 dB |
| Permissible Altitude | 2000ml | 2000m | 2000m | 2000m | 2000m | 2000m | 2000m | 2000m |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 210A Charging: Ultra-high battery charging
- Touch LCD Display: Colorful intuitive interface
- 16 Units Parallel: Scale up to 160kW
- AC Coupling: Retrofit existing systems
- 6 Time Periods: Advanced battery management
- Generator Support: Store diesel generator energy
- 3.6-10kW Output: High efficiency power conversion
- Wide MPPT Range: Optimized for various solar configurations
- IP65 Protection: Suitable for outdoor installation
- Smart Monitoring: Real-time performance tracking
- 90A Charging: Ultra-high battery charging
- 120A Charging: Ultra-high battery charging
Frequently Asked Questions
Is the DEYE SUN-10K-SG05LP1-EU-SM2-P suitable for the Middle East climate?
Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
What makes this the SM2-P version?
The SM2-P revision raises the battery charge and discharge current. This model is rated at 210 A (90–210 A across the 3.6–10 kW range), and adds the finer battery-management control the earlier revision does not have.
How many time periods can I set?
You can configure up to 6 different time periods for battery charging and discharging, allowing optimal energy usage based on specific demands and electricity pricing.
What is the warranty period?
This inverter comes with a 5-year standard warranty, with options for extended warranty available.
Can this be used for off-grid systems?
Yes, this hybrid inverter supports both on-grid and off-grid operation with battery storage.