Deye SUN-M130-220G4/DEYE-SUN-M220-225G4/SUN-M220G4-EU-Q0/DEYE-SUN-M225G4-EU-Q0
130-220W Single Phase Microinverter for residential and commercial solar installations.
Technical Specifications
| Parameter | DEYE-SUN-M130-220G4 | DEYE-SUN-M220-225G4 | SUN-M220G4-EU-Q0 | DEYE-SUN-M225G4-EU-Q0 |
|---|---|---|---|---|
| Protection Features | ||||
| Anti-Islanding Protection | Yes | |||
| Overvoltage Category | OVC II(DC), OVC III(AC) | |||
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||
| AC/DC Surge Protection | TYPE II(AC) | TYPE II(AC) | TYPE II(AC) | TYPEII(AC) |
| Over-Temperature / Thermal Protection | Yes | |||
| IP Rating | IP65 | IP65 | IP67 | IP67 |
| Grid Connection Standards | — | — | IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002, | IEC 61727, IEC 62116, CEI O-21,G98,ENVDE-AR-N50549,NRS4105097, RD 140, UNE 217002, |
| Communication | ||||
| Communication Interface | Wi-Fi | |||
| Electrical / AC Output Data | ||||
| European Efficiency | 96.0% | |||
| AC Grid Connection Type | L+N+PE | L+N+PE | L/N/PE | L/N/PE |
| Topology | Isolated | |||
| Max Efficiency | 96.5% | |||
| Grid / AC Frequency | 50/45-55, 60/55-65 Hz | |||
| Output Voltage Range | 220/230 0.85Un-1.1Un V | |||
| Rated Power | 130-220W | 2200-2250W | — | — |
| Phase | Single Phase | |||
| PV Modules Supported | — | — | 4 × 210-770 W | 4 × 210-790 W |
| Max AC Apparent Power | — | — | 2200 VA | 2250 VA |
| Max AC Output Current | — | — | 10/9.6 A | 10.3/9.8 A |
| Max. PV Input Power | — | — | 3080 W | 3160 W |
| Rated AC Output Active Power | — | — | 2200 W | 2250 W |
| Rated AC Output Current | — | — | 10/9.6 A | 10.3/9.8 A |
| THD / THDi | <3% | |||
| Max Units per Branch | 3 | |||
| Additional Specifications | ||||
| MPPI voltage range | 25-55 V | |||
| Max. Inverter Backfeed Current To the Array | 0 | |||
| Max. Output Fault Current | 16 A | |||
| Max. PV Input Voltage | 60 V | |||
| Max. unit per branch Power Factor Adjustment Range | 0.9leading-O.9lagging/0.95leading-0.95lagging(VDE4105) | |||
| Overvoltage Load Drop Protection | Yes | |||
| Power Network Monitoring | Yes | |||
| Total Current Harmonic Distortion THDi | <3% | |||
| Max. Unit per Branch | 3 | |||
| Permissible Altitude | 2000 m | |||
| Relative Humidity | 0-100% | 0-100% | 0-100% | 0-100% |
| Full Load MPPT Voltage Range | 37.5-55 V | |||
| Max. Operating PV Input Current | 18+18+18+18 A | |||
| Power Factor Adjustment Range | 0.9 leading-0.9 lagging | |||
| Max PV Voltage | 60 V | |||
| MPPT Trackers | 4 | |||
| Max Input Current | 18+18+18+18 A | |||
| Noise | ≤25 dB | |||
| Permissible Ambient Humidity | 0-100% | |||
| PV String Input Data | ||||
| MPPT Efficiency | >99% | |||
| MPPT Nominal Voltage | 42.5 V | |||
| Start-up Voltage | 20 V | |||
| MPPT Voltage Range | 25-55 V | |||
| Max PV Short-Circuit Current | 27+27+27+27 A | |||
| Mechanical Data | ||||
| Cooling Method | Natural cooling | Natural cooling | Natural cooling | Natural Cooling |
| Ingress Protection(IP) Rating | IP 67 | IP 67 | IP 67 | IP67 |
| Cooling | Natural Cooling | |||
| Operating Environment | ||||
| Operating Temperature Range | -40 to +65℃, >45℃ Derating °C | — | -40 to +65℃, >45℃ Derating °C | -40 to +65°C, >45°C Derating |
| Operating Conditions | ||||
| Operating Temperature | -25 to +60 °C | -25 to +60 °C | -40 to 65 °C | -40 to 65 °C |
| Noise Level | ≤25 dB | |||
| Max Altitude | — | — | 2000 m | 2,000 m |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 130-220W Output: High efficiency power conversion
- Wide MPPT Range: Optimized for various solar configurations
- IP65 Protection: Suitable for outdoor installation
- Smart Monitoring: Real-time performance tracking
- 2200-2250W Output: High efficiency power conversion
- Quad MPPT: 4 independent trackers
- Integrated WiFi: Built-in monitoring
- Rapid Shutdown: Enhanced safety features
- IP67 Protection: Fully weatherproof
- Balcony Ready: Quick-plug installation
- 25-Year Design: 10-year warranty
- 2250W Power: High-power microinverter
Frequently Asked Questions
Is the DEYE SUN-M130-220G4 suitable for the Middle East climate?
Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
What is the warranty period?
This inverter comes with a 5-year standard warranty, with options for extended warranty available.
Can this be used for off-grid systems?
This is primarily designed for grid-tied systems. For off-grid applications, consider our hybrid inverter range.
How many panels can I connect?
Each microinverter supports 4 solar panels with quad MPPT trackers for independent optimization of each panel, supporting up to 700W modules.
What is the warranty coverage?
Standard 10-year warranty is included, with an optional 15-year warranty available for installations in Germany and Austria.
How many units can I install per branch?
You can install up to 3 units per branch for the SUN-M225G4, providing flexibility in system design.