Deye BOS-GL60-GH60
A UL9540-listed high-voltage rack of 5.12 kWh modules delivering 61.44 kWh (55.29 kWh usable) and 60 kW, expandable to 960 kWh across parallel racks.
Technical Specifications
| Parameter | DEYE-BOS-GL60-GH60 |
|---|---|
| Battery Data | |
| Energy | 5.12 kWh |
| Usable Energy | 55.29 kWh |
| Module Energy | 5.12 kWh |
| System Energy | 61.44 kWh |
| Max. Capacity | 960 kWh |
| Nominal Voltage | 51.2 V |
| Module Nominal Voltage | 51.2 V |
| System Nominal Voltage | 307.2-614.4 V |
| Operating Voltage | 240-700.8 V |
| Rated Capacity | 100 Ah |
| Module Capacity | 100 Ah |
| Cell Chemistry | LiFePO4 |
| Pack Configuration | 2P6S/1P12S |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70% |
| Recommended Depth of Discharge | 90% |
| Rated DC Power | 60 kW |
| Max. Charge Current | 125 A |
| Max. Discharge Current | 125 A |
| Max. Charge/Discharge Current | 125 A |
| Nominal Charge/Discharge Current | 100 A |
| Recommended Charge/Discharge Current | 100/50 A |
| Peak Discharge Current | 125 A |
| Modules in Series | 4-12 |
| Min. Battery Module Quantity | 4 |
| Battery Module Models | BOS-GH20, BOS-GH25, BOS-GH30, BOS-GH35, BOS-GH40, BOS-GH45, BOS-GH50, BOS-GH55, BOS-GH60 |
| Parallel Units | 16 |
| Protection Features | Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing |
| Warranty (Years) | 10 |
| Mechanical & Interface | |
| Communication Ports | CAN2.0, RS485 |
| Dimensions | 530 x 2219 x 667 mm |
| Additional Notes | Up to 10 AC inverters parallel (600kW/9600kWh); PDU BOS-G-PDU-NA max 125A; GL60=2P6S/100A, GH=1P/50A |
| Module Dimensions | 440 x 133 x 570 mm |
| Module Weight | 45 kg |
| Status Indicator | Yellow: Battery High Voltage Power On; Red: Battery System Alarm |
| Weight | 635 kg |
| Environment & Protection | |
| Altitude | <2000 m |
| Charge Temperature | 0-55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-85% |
| Installation Location | Rack-Mounted |
| Enclosure IP Rating | IP20 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge: 0-55 / Discharge: -20 to 55 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Kuwait
| Market | Kuwait |
| Grid authority / regulator | MEW Kuwait |
| Quotation currency | KWD |
| Support hours timezone | Asia/Kuwait |
| Delivery & installation coverage | Kuwait City, Hawalli, Salmiya |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Kuwait that is MEW Kuwait. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 61.44 kWh from twelve modules: Four to twelve 5.12 kWh, 45 kg modules in series; the full rack holds 61.44 kWh with 55.29 kWh usable at 90% depth of discharge.
- UL9540 on the label: Listed to UL9540, UL9540A and UL1973 alongside UN38.3, the file inspectors want to see.
- 60 kW of DC muscle: Rated DC power of 60 kW with up to 125 A through the BOS-G-PDU-NA distribution unit.
- Two wiring schemes: Supports 2P6S and 1P12S pack configurations; GL60 runs 100 A and GH variants run 1P at 50 A.
- A path to 960 kWh: Up to 16 racks parallel over CAN2.0 and RS485, with as many as 10 AC-coupled inverters cooperating.
- Six thousand cycles deep: LiFePO4 cells retain 70% capacity beyond 6,000 cycles, under a 10-year warranty.
Frequently Asked Questions
What certifications does the BOS-GL60 hold?
UL9540, UL9540A, UL1973 and UN38.3, a listing set that answers North American style storage-safety requirements at the standards level.
How much of the BOS-GL60 rack is usable energy?
Of the 61.44 kWh in a twelve-module rack, 55.29 kWh is usable at the recommended 90% depth of discharge.
How large can a BOS-GL60 project become?
Sixteen racks can run in parallel toward a 960 kWh maximum capacity, and up to 10 inverters can be AC-coupled together.
What is the difference between the GL60 and GH configurations?
GL60 uses a 2P6S pack arrangement carrying 100 A, while GH builds run 1P at 50 A; both draw on the same 5.12 kWh module and share the BOS-G-PDU-NA at up to 125 A.
What voltage and siting does the BOS-GL60 require?
System nominal voltage runs 307.2 to 614.4 V with a 240 to 700.8 V operating window; the IP20 rack weighs 635 kg and belongs indoors below 2,000 m altitude.