Deye BOS-GL60-GH60

A UL9540-listed high-voltage rack of 5.12 kWh modules delivering 61.44 kWh (55.29 kWh usable) and 60 kW, expandable to 960 kWh across parallel racks.

Models Covered: DEYE-BOS-GL60-GH60

Manufacturer: Ningbo Deye Inverter Technology Co., Ltd

Application: Give a commercial building an afternoon of stored solar from a single footprint of 530 x 2219 x 667 mm. The Deye BOS-GL60 arranges 5.12 kWh, 51.2 V modules of 45 kg each, four to twelve in series, into a rack whose full build reaches 61.44 kWh with 55.29 kWh usable at the recommended 90% depth of discharge, and 60 kW of rated DC power behind it. Two wiring schemes are supported, 2P6S and 1P12S: the GL60 arrangement carries 100 A while GH configurations run 1P at 50 A, and the BOS-G-PDU-NA distribution unit tops out at 125 A. Scaling is generous, with up to 16 racks in parallel toward a 960 kWh ceiling and as many as 10 AC-coupled inverters working together. The certification list, UL9540, UL9540A, UL1973 and UN38.3, answers the questions inspectors ask, LiFePO4 cells run past 6,000 cycles to 70% end-of-life, and the warranty is 10 years.

Technical Specifications

Technical Specifications
Parameter DEYE-BOS-GL60-GH60
Battery Data
Energy 5.12 kWh
Usable Energy 55.29 kWh
Module Energy 5.12 kWh
System Energy 61.44 kWh
Max. Capacity 960 kWh
Nominal Voltage 51.2 V
Module Nominal Voltage 51.2 V
System Nominal Voltage 307.2-614.4 V
Operating Voltage 240-700.8 V
Rated Capacity 100 Ah
Module Capacity 100 Ah
Cell Chemistry LiFePO4
Pack Configuration 2P6S/1P12S
Cycle Life >6000
End-of-Life Capacity 70%
Recommended Depth of Discharge 90%
Rated DC Power 60 kW
Max. Charge Current 125 A
Max. Discharge Current 125 A
Max. Charge/Discharge Current 125 A
Nominal Charge/Discharge Current 100 A
Recommended Charge/Discharge Current 100/50 A
Peak Discharge Current 125 A
Modules in Series 4-12
Min. Battery Module Quantity 4
Battery Module Models BOS-GH20, BOS-GH25, BOS-GH30, BOS-GH35, BOS-GH40, BOS-GH45, BOS-GH50, BOS-GH55, BOS-GH60
Parallel Units 16
Protection Features Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing
Warranty (Years) 10
Mechanical & Interface
Communication Ports CAN2.0, RS485
Dimensions 530 x 2219 x 667 mm
Additional Notes Up to 10 AC inverters parallel (600kW/9600kWh); PDU BOS-G-PDU-NA max 125A; GL60=2P6S/100A, GH=1P/50A
Module Dimensions 440 x 133 x 570 mm
Module Weight 45 kg
Status Indicator Yellow: Battery High Voltage Power On; Red: Battery System Alarm
Weight 635 kg
Environment & Protection
Altitude <2000 m
Charge Temperature 0-55 °C
Discharge Temperature -20 to 55 °C
Operating Humidity 5-85%
Installation Location Rack-Mounted
Enclosure IP Rating IP20
Storage Temperature 0-35 °C
Working Temperature Charge: 0-55 / Discharge: -20 to 55 °C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Kuwait

Market Kuwait
Grid authority / regulator MEW Kuwait
Quotation currency KWD
Support hours timezone Asia/Kuwait
Delivery & installation coverage Kuwait City, Hawalli, Salmiya

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Kuwait that is MEW Kuwait. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • 61.44 kWh from twelve modules: Four to twelve 5.12 kWh, 45 kg modules in series; the full rack holds 61.44 kWh with 55.29 kWh usable at 90% depth of discharge.
  • UL9540 on the label: Listed to UL9540, UL9540A and UL1973 alongside UN38.3, the file inspectors want to see.
  • 60 kW of DC muscle: Rated DC power of 60 kW with up to 125 A through the BOS-G-PDU-NA distribution unit.
  • Two wiring schemes: Supports 2P6S and 1P12S pack configurations; GL60 runs 100 A and GH variants run 1P at 50 A.
  • A path to 960 kWh: Up to 16 racks parallel over CAN2.0 and RS485, with as many as 10 AC-coupled inverters cooperating.
  • Six thousand cycles deep: LiFePO4 cells retain 70% capacity beyond 6,000 cycles, under a 10-year warranty.

Frequently Asked Questions

What certifications does the BOS-GL60 hold?

UL9540, UL9540A, UL1973 and UN38.3, a listing set that answers North American style storage-safety requirements at the standards level.

How much of the BOS-GL60 rack is usable energy?

Of the 61.44 kWh in a twelve-module rack, 55.29 kWh is usable at the recommended 90% depth of discharge.

How large can a BOS-GL60 project become?

Sixteen racks can run in parallel toward a 960 kWh maximum capacity, and up to 10 inverters can be AC-coupled together.

What is the difference between the GL60 and GH configurations?

GL60 uses a 2P6S pack arrangement carrying 100 A, while GH builds run 1P at 50 A; both draw on the same 5.12 kWh module and share the BOS-G-PDU-NA at up to 125 A.

What voltage and siting does the BOS-GL60 require?

System nominal voltage runs 307.2 to 614.4 V with a 240 to 700.8 V operating window; the IP20 rack weighs 635 kg and belongs indoors below 2,000 m altitude.