Deye BOS-GL60-GH60

A UL9540-listed high-voltage rack of 5.12 kWh modules delivering 61.44 kWh (55.29 kWh usable) and 60 kW, expandable to 960 kWh across parallel racks.

Models Covered: DEYE-BOS-GL60-GH60

Manufacturer: Ningbo Deye Inverter Technology Co., Ltd

Application: Give a commercial building an afternoon of stored solar from a single footprint of 530 x 2219 x 667 mm. The Deye BOS-GL60 arranges 5.12 kWh, 51.2 V modules of 45 kg each, four to twelve in series, into a rack whose full build reaches 61.44 kWh with 55.29 kWh usable at the recommended 90% depth of discharge, and 60 kW of rated DC power behind it. Two wiring schemes are supported, 2P6S and 1P12S: the GL60 arrangement carries 100 A while GH configurations run 1P at 50 A, and the BOS-G-PDU-NA distribution unit tops out at 125 A. Scaling is generous, with up to 16 racks in parallel toward a 960 kWh ceiling and as many as 10 AC-coupled inverters working together. The certification list, UL9540, UL9540A, UL1973 and UN38.3, answers the questions inspectors ask, LiFePO4 cells run past 6,000 cycles to 70% end-of-life, and the warranty is 10 years.

Technical Specifications

Technical Specifications
Parameter DEYE-BOS-GL60-GH60
Battery Data
Energy 5.12 kWh
Usable Energy 55.29 kWh
Module Energy 5.12 kWh
System Energy 61.44 kWh
Max. Capacity 960 kWh
Nominal Voltage 51.2 V
Module Nominal Voltage 51.2 V
System Nominal Voltage 307.2-614.4 V
Operating Voltage 240-700.8 V
Rated Capacity 100 Ah
Module Capacity 100 Ah
Cell Chemistry LiFePO4
Pack Configuration 2P6S/1P12S
Cycle Life >6000
End-of-Life Capacity 70%
Recommended Depth of Discharge 90%
Rated DC Power 60 kW
Max. Charge Current 125 A
Max. Discharge Current 125 A
Max. Charge/Discharge Current 125 A
Nominal Charge/Discharge Current 100 A
Recommended Charge/Discharge Current 100/50 A
Peak Discharge Current 125 A
Modules in Series 4-12
Min. Battery Module Quantity 4
Battery Module Models BOS-GH20, BOS-GH25, BOS-GH30, BOS-GH35, BOS-GH40, BOS-GH45, BOS-GH50, BOS-GH55, BOS-GH60
Parallel Units 16
Protection Features Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing
Warranty (Years) 10
Mechanical & Interface
Communication Ports CAN2.0, RS485
Dimensions 530 x 2219 x 667 mm
Additional Notes Up to 10 AC inverters parallel (600kW/9600kWh); PDU BOS-G-PDU-NA max 125A; GL60=2P6S/100A, GH=1P/50A
Module Dimensions 440 x 133 x 570 mm
Module Weight 45 kg
Status Indicator Yellow: Battery High Voltage Power On; Red: Battery System Alarm
Weight 635 kg
Environment & Protection
Altitude <2000 m
Charge Temperature 0-55 °C
Discharge Temperature -20 to 55 °C
Operating Humidity 5-85%
Installation Location Rack-Mounted
Enclosure IP Rating IP20
Storage Temperature 0-35 °C
Working Temperature Charge: 0-55 / Discharge: -20 to 55 °C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Yemen

Market Yemen
Grid authority / regulator Public Electricity Corporation (PEC), Ministry of Electricity and Energy
Quotation currency YER
Support hours timezone Asia/Aden
Delivery & installation coverage Sana'a, Aden, Taiz, Al Hudaydah, Mukalla

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • 61.44 kWh from twelve modules: Four to twelve 5.12 kWh, 45 kg modules in series; the full rack holds 61.44 kWh with 55.29 kWh usable at 90% depth of discharge.
  • UL9540 on the label: Listed to UL9540, UL9540A and UL1973 alongside UN38.3, the file inspectors want to see.
  • 60 kW of DC muscle: Rated DC power of 60 kW with up to 125 A through the BOS-G-PDU-NA distribution unit.
  • Two wiring schemes: Supports 2P6S and 1P12S pack configurations; GL60 runs 100 A and GH variants run 1P at 50 A.
  • A path to 960 kWh: Up to 16 racks parallel over CAN2.0 and RS485, with as many as 10 AC-coupled inverters cooperating.
  • Six thousand cycles deep: LiFePO4 cells retain 70% capacity beyond 6,000 cycles, under a 10-year warranty.

Frequently Asked Questions

What certifications does the BOS-GL60 hold?

UL9540, UL9540A, UL1973 and UN38.3, a listing set that answers North American style storage-safety requirements at the standards level.

How much of the BOS-GL60 rack is usable energy?

Of the 61.44 kWh in a twelve-module rack, 55.29 kWh is usable at the recommended 90% depth of discharge.

How large can a BOS-GL60 project become?

Sixteen racks can run in parallel toward a 960 kWh maximum capacity, and up to 10 inverters can be AC-coupled together.

What is the difference between the GL60 and GH configurations?

GL60 uses a 2P6S pack arrangement carrying 100 A, while GH builds run 1P at 50 A; both draw on the same 5.12 kWh module and share the BOS-G-PDU-NA at up to 125 A.

What voltage and siting does the BOS-GL60 require?

System nominal voltage runs 307.2 to 614.4 V with a 240 to 700.8 V operating window; the IP20 rack weighs 635 kg and belongs indoors below 2,000 m altitude.