A UL9540-listed high-voltage rack of 5.12 kWh modules delivering 61.44 kWh (55.29 kWh usable) and 60 kW, expandable to 960 kWh across parallel racks.
Technical Specifications
| Parameter | DEYE-BOS-GL60-GH60 |
|---|---|
| Battery Data | |
| Energy | 5.12 kWh |
| Usable Energy | 55.29 kWh |
| Module Energy | 5.12 kWh |
| System Energy | 61.44 kWh |
| Max. Capacity | 960 kWh |
| Nominal Voltage | 51.2 V |
| Module Nominal Voltage | 51.2 V |
| System Nominal Voltage | 307.2-614.4 V |
| Operating Voltage | 240-700.8 V |
| Rated Capacity | 100 Ah |
| Module Capacity | 100 Ah |
| Cell Chemistry | LiFePO4 |
| Pack Configuration | 2P6S/1P12S |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70% |
| Recommended Depth of Discharge | 90% |
| Rated DC Power | 60 kW |
| Max. Charge Current | 125 A |
| Max. Discharge Current | 125 A |
| Max. Charge/Discharge Current | 125 A |
| Nominal Charge/Discharge Current | 100 A |
| Recommended Charge/Discharge Current | 100/50 A |
| Peak Discharge Current | 125 A |
| Modules in Series | 4-12 |
| Min. Battery Module Quantity | 4 |
| Battery Module Models | BOS-GH20, BOS-GH25, BOS-GH30, BOS-GH35, BOS-GH40, BOS-GH45, BOS-GH50, BOS-GH55, BOS-GH60 |
| Parallel Units | 16 |
| Protection Features | Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing |
| Warranty (Years) | 10 |
| Mechanical & Interface | |
| Communication Ports | CAN2.0, RS485 |
| Dimensions | 530 x 2219 x 667 mm |
| Additional Notes | Up to 10 AC inverters parallel (600kW/9600kWh); PDU BOS-G-PDU-NA max 125A; GL60=2P6S/100A, GH=1P/50A |
| Module Dimensions | 440 x 133 x 570 mm |
| Module Weight | 45 kg |
| Status Indicator | Yellow: Battery High Voltage Power On; Red: Battery System Alarm |
| Weight | 635 kg |
| Environment & Protection | |
| Altitude | <2000 m |
| Charge Temperature | 0-55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-85% |
| Installation Location | Rack-Mounted |
| Enclosure IP Rating | IP20 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge: 0-55 / Discharge: -20 to 55 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 61.44 kWh from twelve modules: Four to twelve 5.12 kWh, 45 kg modules in series; the full rack holds 61.44 kWh with 55.29 kWh usable at 90% depth of discharge.
- UL9540 on the label: Listed to UL9540, UL9540A and UL1973 alongside UN38.3, the file inspectors want to see.
- 60 kW of DC muscle: Rated DC power of 60 kW with up to 125 A through the BOS-G-PDU-NA distribution unit.
- Two wiring schemes: Supports 2P6S and 1P12S pack configurations; GL60 runs 100 A and GH variants run 1P at 50 A.
- A path to 960 kWh: Up to 16 racks parallel over CAN2.0 and RS485, with as many as 10 AC-coupled inverters cooperating.
- Six thousand cycles deep: LiFePO4 cells retain 70% capacity beyond 6,000 cycles, under a 10-year warranty.
Frequently Asked Questions
What certifications does the BOS-GL60 hold?
UL9540, UL9540A, UL1973 and UN38.3, a listing set that answers North American style storage-safety requirements at the standards level.
How much of the BOS-GL60 rack is usable energy?
Of the 61.44 kWh in a twelve-module rack, 55.29 kWh is usable at the recommended 90% depth of discharge.
How large can a BOS-GL60 project become?
Sixteen racks can run in parallel toward a 960 kWh maximum capacity, and up to 10 inverters can be AC-coupled together.
What is the difference between the GL60 and GH configurations?
GL60 uses a 2P6S pack arrangement carrying 100 A, while GH builds run 1P at 50 A; both draw on the same 5.12 kWh module and share the BOS-G-PDU-NA at up to 125 A.
What voltage and siting does the BOS-GL60 require?
System nominal voltage runs 307.2 to 614.4 V with a 240 to 700.8 V operating window; the IP20 rack weighs 635 kg and belongs indoors below 2,000 m altitude.