Deye GB-L-PRO
A floor-standing high-voltage stack of 4 kWh, 102.4 V modules reaching 8 to 24 kWh, IP65-sealed with explosion relief and fire protection built in.
Technical Specifications
| Parameter | DEYE-GB-L-PRO |
|---|---|
| Battery Data | |
| Energy | 4 kWh |
| Usable Energy | 7.2-21.6 kWh |
| Module Energy | 4 kWh |
| System Energy | 8-24 kWh |
| Nominal Voltage | 102.4 V |
| Module Nominal Voltage | 102.4 V |
| System Nominal Voltage | 204.8-614.4 V |
| Operating Voltage | 166.4-700.8 V |
| Rated Capacity | 40 Ah |
| Module Capacity | 40 Ah |
| Cell Chemistry | LiFePO4 |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70% |
| Recommended Depth of Discharge | 90% |
| Max. Charge Current | 40 A |
| Max. Discharge Current | 40 A |
| Max. Charge/Discharge Current | 40 A |
| Nominal Charge/Discharge Current | 40 A |
| Recommended Charge/Discharge Current | 20 A |
| Peak Discharge Current | 50 (120s) A |
| Modules in Series | 2-6 |
| Min. Battery Module Quantity | 2 |
| Battery Module Models | GB-L8-Pro, GB-L12-Pro, GB-L16-Pro, GB-L20-Pro, GB-L24-Pro |
| Protection Features | Explosion Relief, Fire Protection |
| Warranty (Years) | 10 |
| Mechanical & Interface | |
| Communication Ports | CAN2.0, RS485 |
| Dimensions | 540 x 1530 x 385 mm |
| Additional Notes | Remote Updates |
| Module Dimensions | 540 x 220 x 385 mm |
| Module Weight | 39 kg |
| Status Indicator | LCD: SOC, Power, Total Voltage |
| Weight | 97-253 kg |
| Environment & Protection | |
| Altitude | <2000 m |
| Anti-Corrosion Grade | >C2 |
| Charge Temperature | -20 to 55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-90% |
| Installation Location | Floor-Mounted |
| Enclosure IP Rating | IP65 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge: -20 to 55 / Discharge: -20 to 55 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 102.4 V in every module: Each 4 kWh module supplies 102.4 V, so two to six build 8 to 24 kWh at 204.8 to 614.4 V.
- Explosion relief built in: Explosion relief and fire protection are part of the pack design, not accessories.
- Skin graded for coasts: An anti-corrosion rating above C2 plus IP65 sealing stand up to humid, salty air.
- Charges at -20 degrees C: Both charge and discharge are rated across the -20 to 55 degrees C range.
- Updates without a visit: Remote firmware updates arrive over the CAN2.0 and RS485 links.
- A six-thousand-cycle core: LiFePO4 cells keep 70% capacity beyond 6,000 cycles, warranted 10 years.
Frequently Asked Questions
Why does the GB-L Pro need so few modules?
Because each module contributes 102.4 V and 4 kWh, two to six of them already form a 204.8 to 614.4 V system holding 8 to 24 kWh.
What safety hardware does the GB-L Pro carry?
Explosion relief and fire protection are engineered into the pack, complemented by an IP65 enclosure and an anti-corrosion grade above C2.
Is the GB-L Pro suitable near the sea?
Its corrosion resistance is graded above C2 and the housing is IP65-sealed, which is exactly the specification coastal humidity calls for.
What does the GB-L Pro display and report?
A front LCD shows state of charge, power and total voltage, while CAN2.0 and RS485 carry data, and remote updates, to the inverter side.
What are the GB-L Pro weight and current figures?
Modules weigh 39 kg each and towers 97 to 253 kg; current is 40 A continuous with a 50 A peak sustained for 120 seconds, 20 A being recommended.