Deye SUN-10/12/3/4/5/6/8K-SG05LP3-EU-SM2
10kW three phase hybrid inverter with 210A charging and transformer isolation.
Technical Specifications
| Parameter | SUN-10K-SG05LP3-EU-SM2 | SUN-12K-SG05LP3-EU-SM2 | SUN-3K-SG05LP3-EU-SM2 | SUN-4K-SG05LP3-EU-SM2 | SUN-5K-SG05LP3-EU-SM2 | SUN-6K-SG05LP3-EU-SM2 | SUN-8K-SG05LP3-EU-SM2 |
|---|---|---|---|---|---|---|---|
| Additional Specifications | |||||||
| MPPT Voltage Range (V) | 200-650 | ||||||
| Max. Continuous AC Passthrough (grid to load) (A) | 45 | ||||||
| Max. PV Input Voltage (V) | 800 | ||||||
| Peak Power (off-grid) (W) | 10s | ||||||
| Rated PV Input Voltage (V) | 550 | ||||||
| Max PV Voltage | 800 | ||||||
| Rated output voltage | 220/380V,230/400V | ||||||
| Peak Power (off-grid)(W) | 2 | ||||||
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | ||||||
| Grid Connection Form | 3L+N+PE | ||||||
| Ground Fault Current Monitoring | Yes | ||||||
| Island Protection Monitoring | Yes | ||||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | ||||||
| Overvoltage Load Drop Protection | Yes | ||||||
| Power Network Monitoring | Yes | ||||||
| Rated input/output voltage | 220/380V,230/400V 0.85Un-1.1Un 3L+N+PE | ||||||
| Residual Current (RCD) Detection | Yes | ||||||
| MPPT Trackers | 2 | ||||||
| PV Input Voltage Range | 160-800 V | ||||||
| Max. Output Overcurrent Protection | 70 A | ||||||
| DC Polarity Reverse Connection Protection | Yes | ||||||
| DC Terminal Insulation Impedance Monitoring | Yes | ||||||
| PV Input Voltage Range(V) | 160-800 | ||||||
| AC Output Overcurrent Protection | Yes | ||||||
| AC Output Overvoltage Protection | Yes | ||||||
| AC Output Short Circuit Protection | Yes | ||||||
| Rated Input/Output Grid Frequency/Range 50Hz/45Hz-55Hz | 60Hz/55Hz-65Hz | ||||||
| Electrical / AC Output Data | |||||||
| Max. AC Input/Output Apparent Power (VA) | 11000 | 13200 | 3300 | 4400 | 5500 | 6600 | 8800 |
| Max. AC Input/Output Current (A) | 16.7/16 | 20/19.2 | 5/4.8 | 6.7/6.4 | 8.4/8 | 10/9.6 | 13.4/12.8 |
| Max. Charging/Discharging Current (A) | 210 | 240 | 70 | 95 | 120 | 135 | 190 |
| Max. PV Input Power (W) | 16000 | 19200 | 4800 | 6400 | 8000 | 9600 | 12800 |
| Max. PV access power (W) | 20000 | 24000 | 6000 | 8000 | 10000 | 12000 | 16000 |
| Rated AC Input/Output Active Power (W) | 10000 | 12000 | 3000 | 4000 | 5000 | 6000 | 8000 |
| Rated AC Input/Output Current (A) | 15.2/14.5 | 18.2/17.4 | 4.6/4.4 | 6.1/5.8 | 7.6/7.3 | 9.1/8.7 | 12.2/11.6 |
| Grid Frequency | 60Hz/55Hz-65Hz | 60Hz/55Hz-65Hz | — | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 60Hz/55Hz-65Hz |
| AC Grid Connection Type | Hybrid Inverter | ||||||
| No. of Strings MPP Tracker | 2+2 | 2+2 | 1+1 | 1+1 | 1+1 | 1+1 | 2+2 |
| No. of MPP Trackers/No. of Strings MPP Tracker | 2/2+2 | 2/2+2 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/2+2 |
| European Efficiency | 97.0% | ||||||
| Full Load MPPT Voltage Range | 350-650 V | 350-650 V | 250-650 V | 250-650 V | 250-650 V | 250-650 V | 350-650 V |
| Topology | Non-Isolated (solar), Isolated (battery) | ||||||
| Max. AC Input/Output Apparent Power | 11000 VA | 13200 VA | 3300 VA | 4400 VA | 5500 VA | 6600 VA | 8800 VA |
| Max. AC Input/Output Current | 16.7/16 A | 20/19.2 A | 5/4.8 A | 6.7/6.4 A | 8.4/8 A | 10/9.6 A | 13.4/12.8 A |
| Max. Charging Current | 210 A | 240 A | 70 A | 95 A | 120 A | 135 A | 190 A |
| Max. Continuous AC Passthrough (grid to load) | 45 A | ||||||
| Max. Discharging Current | 210 A | 240 A | 70 A | 95 A | 120 A | 135 A | 190 A |
| Max Efficiency | 97.6% | ||||||
| Max Inverter Backfeed Current | 0 | ||||||
| Adjustable Power Factor Range | 0.8 leading to 0.8 lagging | ||||||
| Rated AC Input/Output Current | 15.2/14.5 A | 18.2/17.4 A | 4.6/4.4 A | 6.1/5.8 A | 7.6/7.3 A | 9.1/8.7 A | 12.2/11.6 A |
| Rated Input/Output Grid Frequency/Range | 60Hz/55Hz-65Hz | 60Hz/55Hz-65Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 50Hz/45Hz-55Hz | 60Hz/55Hz-65Hz |
| Nominal AC Voltage Range | 220/380V,230/400V 0.85Un-1.1Un | ||||||
| THD / THDi | <3% (of nominal power) | ||||||
| Peak / Surge Power (W) | 2 times of rated power, 10s | ||||||
| Rated AC Power | 10000 W | 12000 W | 3000 W | 4000 W | 5000 W | 6000 W | 8000 W |
| Max Parallel Units | 10 pcs | ||||||
| Unbalanced Output | 100% | ||||||
| Max. Three-phase Unbalanced Output Current | 22.7/21.7 A | 27.3/26.1 A | — | — | — | — | — |
| Max. Output Fault Current | 33.4 A | 40 A | — | — | — | — | — |
| DC Injection Current | <0.5%In | <0.5%In | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
| Phase | Three-phase | ||||||
| Max. Output Fault Current(A) | — | — | 10 | 13.4 | 16.8 | 20 | 26.8 |
| Output Voltage Range | 0.85Un-1.1Un | ||||||
| Electrical Data | |||||||
| Start-up Voltage (V) | 160 | ||||||
| Max. Charging/Discharging Current | 210 A | 240 A | 70 A | 95 A | 120 A | 135 A | 190 A |
| Rated AC Input/Output Active Power | 10000 W | 12000 W | 3000 W | 4000 W | 5000 W | 6000 W | 8000 W |
| Battery Data | |||||||
| Supported Battery Type | Lead-acid or Lithium-ion | ||||||
| Battery Voltage Range | 40-60 V | ||||||
| Number of Battery Inputs | 1 | ||||||
| Max Charge Current | 210 A | 240 A | 70 A | 95 A | 120 A | 135 A | 190 A |
| Communication | |||||||
| Communication Interface | WIFI,RS485,CAN | ||||||
| Display | LCD | ||||||
| Protection Features | |||||||
| Grid Connection Standards | IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097, RD4105140, UNE 217002, | ||||||
| Overvoltage Category | OVC II(DC), OVC III(AC) | ||||||
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||||
| AC/DC Surge Protection | TYPE II(DC), TYPE II(AC) | ||||||
| Over-Temperature / Thermal Protection | Yes | ||||||
| IP Rating | IP 65 | ||||||
| PV String Input Data | |||||||
| MPPT Efficiency | >99% | ||||||
| MPPT Voltage Range | 200-650 V | ||||||
| Max PV Short-Circuit Current | 39+39 A | 39+39 A | 30+30 A | 30+30 A | 30+30 A | 30+30 A | 39+39 A |
| Max PV Input Current | 26+26 A | 26+26 A | 20+20 A | 20+20 A | 20+20 A | 20+20 A | 26+26 A |
| Max. PV Input Power | 16000 W | 19200 W | 4800 W | 6400 W | 8000 W | 9600 W | 12800 W |
| Max. PV Input Voltage | 800 V | ||||||
| Max. PV access power | 20000 W | 24000 W | 6000 W | 8000 W | 10000 W | 12000 W | 16000 W |
| Rated PV Input Voltage | 550 V | ||||||
| Start-up Voltage | 160 V | ||||||
| Mechanical Data | |||||||
| Type of Cooling | Intelligent Air Cooling | ||||||
| Cooling Method | Intelligent Air Cooling | ||||||
| Operating Conditions | |||||||
| Noise Level | ≤ 55 dB | ||||||
| Operating Temperature | -40 to +60℃, >45℃ Derating | ||||||
| Max Altitude | 3000m | ||||||
| Relative Humidity | 0-100% | ||||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 210A Charging: High power charging
- 48V Low Voltage: Transformer isolation design
- 100% Unbalanced: 50% rated power per phase
- 10 Units Parallel: Scale up to 100kW
- AC Coupling: Retrofit existing systems
- 6 Time Periods: Advanced battery management
- 240A Charging: High power charging
- 70A Charging: High power charging
- 95A Charging: High power charging
- 120A Charging: High power charging
- 135A Charging: High power charging
- 190A Charging: High power charging
Frequently Asked Questions
Is the DEYE SUN-10K-SG05LP3-EU-SM2 suitable for the Middle East climate?
Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
What is transformer isolation?
Transformer isolation provides galvanic separation between the battery and AC side, enhancing safety and allowing the use of various battery types including lead-acid and lithium-ion.
What does 100% unbalanced output mean?
It means each phase can deliver up to 50% of the rated power independently, providing flexibility for unbalanced loads across the three phases.