Deye SUN-1-4K-G04P1/SUN-1.5K-G04P1-EU-AM1/SUN-1K-G04P1-EU-AM1/SUN-2.2K-G04P1-EU-AM1/SUN-2.5K-G04P1-EU-AM1/SUN-2.7K-G04P1-EU-AM1/SUN-2K-G04P1-EU-AM1/SUN-3.3K-G04P1-EU-AM1/SUN-3.6K-G04/SUN-3.6K-G04P1-EU-AM1/SUN-3K-G04P1-EU-AM1/SUN-4K-G04P1-EU-AM1
String Inverter 1-4kW monophasé pour installations solaires résidentielles et commerciales.
Spécifications techniques
| Paramètre | DEYE-SUN-1-4K-G04P1 | SUN-1.5K-G04P1-EU-AM1 | SUN-1K-G04P1-EU-AM1 | SUN-2.2K-G04P1-EU-AM1 | SUN-2.5K-G04P1-EU-AM1 | SUN-2.7K-G04P1-EU-AM1 | SUN-2K-G04P1-EU-AM1 | SUN-3.3K-G04P1-EU-AM1 | SUN-3.6K-G04 | SUN-3.6K-G04P1-EU-AM1 | SUN-3K-G04P1-EU-AM1 | SUN-4K-G04P1-EU-AM1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Données électriques | ||||||||||||
| Tension de sortie nominale | 220/230 | |||||||||||
| Tension PV max | 550 V | |||||||||||
| Puissance d'entrée PV max | 5.2 | — | 1.3 | — | — | 3.5 | — | 4.3 | — | 4.7 | 3.9 | 5.2 |
| Puissance apparente de sortie AC max | 4.4 | — | 1.1 | — | — | 2.97 | — | 3.63 | — | 3.96 | 3.3 | 4.4 |
| Rendement européen | 97.0% | 96.9% | 96.9% | 96.9% | 96.9% | 96.9% | 96.9% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% |
| Nombre de MPPT / chaînes par MPPT | 1/1 | |||||||||||
| Type de raccordement au réseau | L/N/PE | |||||||||||
| Réglementation réseau | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105 | |||||||||||
| Courant de retour max de l'onduleur vers le champ | 0 | |||||||||||
| Protection max contre surintensité de sortie | 35.8 A | |||||||||||
| Catégorie de surtension | OVC II(DC), OVC III(AC) | |||||||||||
| Plage réglable du facteur de puissance | 0.8 leading to 0.8 lagging | |||||||||||
| Tension/plage de sortie nominale | 220/230 0.85Un-1.1Un V | |||||||||||
| Tension de démarrage | 80 V | |||||||||||
| Niveau de protection contre les surtensions | TYPE II(DC), TYPE II(AC) | |||||||||||
| Protection thermique | Yes | |||||||||||
| Puissance nominale | 1-4kW | |||||||||||
| Plage de tension d'entrée PV | 80-550 V | |||||||||||
| Nombre de chaînes par MPPT | 1 | |||||||||||
| Courant de défaut de sortie max | — | 13 A | 8.8 A | 19.2 A | 21.8 A | 23.6 A | 17.4 A | 28.8 A | 31.4 A | 31.4 A | 26.2 A | 34.8 A |
| Puissance active de sortie AC nominale | — | 1.5 kW | 1 kW | 2.2 kW | 2.5 kW | 2.7 kW | 2 kW | 3.3 kW | 3.6 kW | 3.6 kW | 3 kW | 4 kW |
| Tension de démarrage | 80 | |||||||||||
| Tension d'entrée PV nominale | 360 | |||||||||||
| Plage de tension MPPT à pleine charge | — | — | — | — | — | 270-500 | — | 330-500 | — | 325-500 | 270-500 | 360-500 |
| Courant de défaut de sortie max | — | — | — | — | — | 23.6 | — | 28.8 | — | 31.4 | 26.2 | 34.8 |
| Plage de tension d'entrée PV | 80-550 | |||||||||||
| Conditions de fonctionnement | ||||||||||||
| Protection anti-îlotage | yes | |||||||||||
| Surveillance du courant de défaut à la terre | Yes | |||||||||||
| Protection par délestage en surtension | Yes | |||||||||||
| Surveillance du réseau électrique | Yes | |||||||||||
| Détection du courant résiduel (RCD) | Yes | |||||||||||
| Distorsion harmonique totale du courant THDi | <3% | |||||||||||
| Surveillance anti-îlotage | Yes | |||||||||||
| Courant de sortie AC max | 5/4.8 7.5/7.2 A | 7.5/7.2 A | 5/4.8 A | 11/10.6 A | 12.5/12 A | 13.5/13 A | 10/9.6 A | 16.5/15.8 A | 18/17.3 A | 18/17.3 A | 15/14.4 A | 20/19.2 A |
| Rendement max | 97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.3% | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% |
| Tension d'entrée PV nominale | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 420 V | 420 V | 420 V | 360 V | 420 V |
| Interrupteur DC | yes | |||||||||||
| Indice de protection (IP) | IP 65 | |||||||||||
| Plage de température de fonctionnement | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25℃ to +60℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C | -25 to +65℃,>45℃ derating °C |
| Altitude admissible | 2000 m | |||||||||||
| Trackers MPPT | — | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 1 | 1 | 1 |
| Poids | 6.35 kg | |||||||||||
| Protection contre surintensité de sortie AC | Yes | |||||||||||
| Protection contre surtension de sortie AC | Yes | |||||||||||
| Protection contre court-circuit de sortie AC | Yes | |||||||||||
| Disjoncteur de défaut d'arc (AFCI) | Optional | |||||||||||
| Surveillance de la composante DC | Yes | |||||||||||
| Protection contre l'inversion de polarité DC | Yes | |||||||||||
| Surveillance de l'impédance d'isolement des bornes DC | Yes | |||||||||||
| Détection de défaut de terre | Yes | |||||||||||
| Fréquence/plage réseau de sortie nominale | 50/45-55, 60/55-65 | |||||||||||
| Tension/plage de sortie nominale | 220/230 0.85Un-1.1Un | |||||||||||
| Nombre de trackers MPPT | 1 | |||||||||||
| Puissance active d'entrée/sortie AC nominale | 3600 W | |||||||||||
| Puissance apparente d'entrée/sortie AC max | 3960 VA | |||||||||||
| Courant d'entrée/sortie AC nominal | 16.4/15.7 A | |||||||||||
| Courant d'entrée/sortie AC max | 18/17.2 A | |||||||||||
| Données électriques | ||||||||||||
| Interface de communication | RS485/RS232 | |||||||||||
| Mode de surveillance | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||||||||||
| Données électriques / sortie CA | ||||||||||||
| Topologie de l'onduleur | Non-Isolated | |||||||||||
| Fréquence/plage réseau de sortie nominale | 50/45-55, 60/55-65 Hz | |||||||||||
| Plage de tension MPPT à pleine charge | 90-500 140-500 V | 140-500 V | 90-500 V | 225-500 V | 225-500 V | 270-500 V | 180-500 V | 330-500 V | 325-500 V | 325-500 V | 270-500 V | 360-500 V |
| Courant de sortie AC nominal | 4.6/4.4 6.8/6.5 A | 6.8/6.5 A | 4.6/4.4 A | 10/9.6 A | 11.4/10.9 12.3/11.8 13.7/13.1 A | 11.4/10.9 12.3/11.8 13.7/13.1 A | 9.1/8.7 A | 15/14.4 A | 16.4/15.7 18.2/17.4 A | 16.4/15.7 18.2/17.4 A | 11.4/10.9 12.3/11.8 13.7/13.1 A | 16.4/15.7 18.2/17.4 A |
| Phase | Single Phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | Single-phase | — | Single-phase | Single-phase | Single-phase |
| Puissance apparente de sortie AC max | — | 1.65 kVA | 1.1 kVA | 2.42 kVA | 2.75 kVA | 2.97 kVA | 2.2 kVA | 3.63 kVA | 3.96 kVA | 3.96 kVA | 3.3 kVA | 4.4 kVA |
| Puissance AC nominale | — | 1.5 kW | 1 kW | 2.2 kW | 2.5 kW | 2.7 kW | 2 kW | 3.3 kW | 3.6 kW | 3.6 kW | 3 kW | 4 kW |
| Courant de fonctionnement max | — | 20 A | 20 A | 20 A | 20 A | 20 A | 20 A | 20 A | 13+13 A | 20 A | 20 A | 20 A |
| Courant d'injection DC | — | — | <0.5%In | — | — | <0.5%In | — | <0.5%In | <0.5%ln | <0.5%ln | <0.5%In | <0.5%In |
| Plage de tension MPPT | 70-500 | |||||||||||
| Courant de sortie AC max | — | — | 5/4.8 | — | — | 13.5/13.0 | — | 16.5/15.8 | — | 18/17.3 | 15/14.4 | 20/19.2 |
| Courant de court-circuit d'entrée max | 30 | |||||||||||
| Courant d'entrée PV max en fonctionnement | 20 | |||||||||||
| Tension d'entrée PV max | 550 | |||||||||||
| Puissance active de sortie AC nominale | — | — | 1 | — | — | 2.7 | — | 3.3 | — | 3.6 | 3 | 4 |
| Courant de sortie AC nominal | — | — | 4.6/4.4 | — | — | 12.3/11.8 | — | 15.0/14.4 | — | 16.4/15.7 | 13.7/13.1 | 18.2/17.4 |
| Protection max contre surintensité de sortie | 35.8 | |||||||||||
| Détection de l'impédance d'isolement | Yes | |||||||||||
| Données d'entrée PV | ||||||||||||
| Rendement MPPT | >99% | |||||||||||
| Plage de tension MPPT | 70-500 V | |||||||||||
| Courant de court-circuit d'entrée max | 30 A | |||||||||||
| Courant d'entrée PV max en fonctionnement | 20 A | |||||||||||
| Tension d'entrée PV max | 550 V | |||||||||||
| Puissance d'entrée PV max | — | 2 kW | 1.3 kW | 2.9 kW | 3.3 kW | 3.5 kW | 2.6 kW | 4.3 kW | 4.7 kW | 4.7 kW | 3.9 kW | 5.2 kW |
| Plage de tension de fonctionnement PV | 125 V – 500 V | |||||||||||
| Données mécaniques | ||||||||||||
| Normes de sécurité / EMC | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||||||
| Indice IP | IP65 | |||||||||||
| Protection contre l'inversion de polarité DC | Yes | |||||||||||
| Données mécaniques | ||||||||||||
| Type de refroidissement | Natural cooling | Natural cooling | — | Natural Cooling | Natural Cooling | — | Natural Cooling | — | — | — | — | — |
| Poids | 5.6 | |||||||||||
| Refroidissement | Natural Cooling | |||||||||||
| Niveau sonore | ≤35 | |||||||||||
| Type de refroidissement | — | — | Natural cooling | — | — | Natural Cooling | — | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling | Natural Cooling |
| Conditions de fonctionnement | ||||||||||||
| Bruit | ≤35 dB | |||||||||||
| Humidité ambiante admissible | 0-100% | |||||||||||
| Température de fonctionnement | -25 to +60 °C | |||||||||||
| Plage de température de fonctionnement | -25 to +65°C, >45°C Derating | |||||||||||
| Données électriques | ||||||||||||
| Type | String Inverter | |||||||||||
| Conditions de fonctionnement | ||||||||||||
| Altitude admissible | 2000m | |||||||||||
Les valeurs sont mesurées dans les conditions d’essai indiquées par la fiche du fabricant. Un tiret signifie que le fabricant ne publie aucune valeur pour ce modèle.
Disponibilité et conformité réseau en Yémen
| Marché | Yémen |
| Autorité / régulateur du réseau | Public Electricity Corporation (PEC), ministère de l'Électricité et de l'Énergie |
| Devise de cotation | YER |
| Fuseau horaire du support | Asia/Aden |
| Couverture livraison et installation | Sanaa, Aden, Taïz, Hodeïda, Moukalla |
Les valeurs de cette page sont celles du fabricant, mesurées dans les conditions d'essai indiquées par la fiche technique : elles ne changent pas d'un pays à l'autre. Ce qui change, c'est l'agrément exigé avant la mise sous tension : en Yémen, il relève de Public Electricity Corporation (PEC), ministère de l'Électricité et de l'Énergie. Vérifiez le code réseau, les exigences d'importation et toute certification locale auprès d'eux, ou auprès de nous, avant de commander.
Caractéristiques principales
- Sortie 1-4kW: Conversion de puissance haute efficacité
- Large Plage MPPT: Optimisé pour diverses configurations solaires
- Protection IP65: Adapté à l'installation extérieure
- Surveillance intelligente: Suivi des performances en temps réel
- Rendement 97,5%: Conversion d'énergie élevée
- Démarrage 80V: Fonctionne en faible luminosité
- Zéro export: Gestion des limites d'export réseau
- Support VSG: Contribution à la stabilité du réseau
- Refroidissement naturel: Fonctionnement silencieux
- Double MPPT: Deux trackers indépendants
- Zero Export: Gestion de l'export réseau
- Anti-PID: Prévient la dégradation des panneaux
Questions fréquentes
Le DEYE SUN-1-4K-G04P1 convient-il au climat du Moyen-Orient ?
Oui. Les onduleurs DEYE sont conçus pour les températures élevées et la poussière du Golfe, de l'Afrique du Nord et de la région MEA, avec des boîtiers indice IP pour une installation extérieure à l'ombre.
Comment obtenir le prix et la disponibilité du SUN-1-4K-G04P1 ?
Utilisez le bouton « Obtenir le prix » ou contactez-nous sur WhatsApp — nous vous mettons en relation avec un distributeur DEYE agréé de votre région.
Quelle est la période de garantie ?
Cet onduleur est livré avec une garantie standard de 5 ans, avec options de garantie étendue disponibles.
Quelle est la tension de démarrage ?
Le SUN-1-4K-G04P1-EU démarre à seulement 80V, permettant des performances optimales même en conditions de faible luminosité comme le matin tôt ou les jours nuageux.
Supporte-t-il le zéro export ?
Oui ! La fonctionnalité zéro export permet de gérer la consommation d'énergie et de maximiser l'autoconsommation, en respectant les limites d'export du réseau.
Quelle est l'entrée PV maximale ?
Le SUN-3.6K supporte jusqu'à 4,7kW d'entrée PV, tandis que le SUN-6.2K supporte jusqu'à 8,06kW, permettant des ratios DC/AC élevés.
Est-ce adapté à un usage commercial ?
Oui ! Avec des puissances de 3,6kW à 6,2kW et des fonctionnalités avancées comme zero export et support VSG, il convient aux installations résidentielles et commerciales.