Deye

Deye BOS-A

A high-voltage rack battery built from 7.68 kWh LiFePO4 modules, seven to twenty-one in series, delivering 53.76 to 161.28 kWh per rack for commercial systems.

Models Covered: DEYE-BOS-A

Manufacturer: Ningbo Deye Inverter Technology Co., Ltd

Application: Keep a workshop, farm or small commercial site running on stored solar with a rack that grows one drawer at a time. The Deye BOS-A is assembled from 7.68 kWh, 38.4 V modules (BOS-A-Pack7.68, 200 Ah each) slotted seven to twenty-one high, giving a single rack 53.76 to 161.28 kWh, of which 48.38 to 145.15 kWh is usable at the recommended 90% depth of discharge. Its high-voltage bus spans 268.8 to 806.4 V nominal, and the PDU carries two DC interfaces sized for 50-100 kW hybrid inverters, with up to 10 inverters allowed in AC parallel and up to 16 racks side by side. LiFePO4 cells rated past 6,000 cycles retain 70% of capacity at end of life, while the BMS guards against over-charge, over-discharge, over-current and temperature faults with active cell balancing. Certification covers CE, IEC62619, IEC62040, UN38.3 and VDE-2510, and the warranty spans 10 years.

Technical Specifications

Technical Specifications
Parameter DEYE-BOS-A
Battery Data
Energy 7.68 kWh
Usable Energy 48.38-145.15 kWh
Module Energy 7.68 kWh
System Energy 53.76-161.28 kWh
Nominal Voltage 38.4 V
Module Nominal Voltage 38.4 V
System Nominal Voltage 268.8-806.4 V
Operating Voltage 235.2-919.8 V
Rated Capacity 200 Ah
Module Capacity 200 Ah
Cell Chemistry LiFePO4
Cycle Life >6000
End-of-Life Capacity 70%
Recommended Depth of Discharge 90%
Max. Charge Current 160 A
Max. Discharge Current 160 A
Max. Charge/Discharge Current 160 A
Nominal Charge/Discharge Current 160 A
Recommended Charge/Discharge Current 100 A
Modules in Series 7-21
Min. Battery Module Quantity 7
Battery Module Models BOS-A100, BOS-A160
Parallel Units 16
Protection Features Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing
Warranty (Years) 10
Mechanical & Interface
Communication Ports CAN2.0
Dimensions 610 x 1900 x 610 mm
Additional Notes Two inverter DC interfaces; 50-100kW hybrid inverters; up to 10 inverters AC parallel; PDU BOS-A-PDU-2, module BOS-A-Pack7.68
Module Dimensions 601.5 x 135 x 520 mm
Module Weight 70 kg
Status Indicator Yellow: Battery High Voltage Power On; Red: Battery System Alarm
Weight 525-1501 kg
Environment & Protection
Altitude <3000 m
Charge Temperature 0-55 °C
Discharge Temperature -20 to 55 °C
Operating Humidity 5-85%
Installation Location Rack-Mounted (3U)
Enclosure IP Rating IP20
Storage Temperature 0-35 °C
Working Temperature Charge: 0-55 / Discharge: -20 to 55 °C

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Iraq

Market Iraq
Grid authority / regulator Ministry of Electricity Iraq
Quotation currency IQD
Support hours timezone Asia/Baghdad
Delivery & installation coverage Baghdad, Basra, Erbil, Mosul

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Iraq that is Ministry of Electricity Iraq. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • 7.68 kWh building blocks: Each BOS-A-Pack7.68 module holds 7.68 kWh at 38.4 V with a 200 Ah rating.
  • Up to 161.28 kWh per rack: Seven to twenty-one modules in series span 53.76 to 161.28 kWh, of which 48.38 to 145.15 kWh is usable at 90% depth of discharge.
  • Made for 50-100 kW hybrids: The BOS-A-PDU-2 exposes two DC interfaces sized for 50-100 kW hybrid inverters, with up to 10 inverters in AC parallel.
  • Five-way BMS protection: Guards against over-charge, over-discharge, over-current and temperature faults, with active cell balancing.
  • Parallelism at fleet scale: Up to 16 racks coordinate over CAN2.0 as one storage plant.
  • Endurance past 6,000 cycles: LiFePO4 cells rated beyond 6,000 cycles to 70% end-of-life, under a 10-year warranty.

Frequently Asked Questions

What voltage class is the BOS-A?

It is a high-voltage system: 268.8 to 806.4 V nominal depending on module count, with an operating window of 235.2 to 919.8 V, so it belongs with high-voltage battery inverters.

Which inverter sizes suit the BOS-A?

The PDU (BOS-A-PDU-2) provides two DC interfaces intended for 50-100 kW hybrid inverters, and up to 10 inverters can run in AC parallel on larger sites.

How much energy can one BOS-A rack hold?

Between 53.76 and 161.28 kWh depending on whether 7 or 21 modules are fitted, with 48.38 to 145.15 kWh usable at 90% depth of discharge; 16 racks can be paralleled beyond that.

Where should a BOS-A be installed?

Indoors: the enclosure is rated IP20 and rack-mounted in 3U module format, measuring 610 x 1900 x 610 mm and weighing 525 to 1,501 kg depending on configuration.

What lifetime and warranty does the BOS-A carry?

Cycle life exceeds 6,000 cycles to 70% end-of-life capacity, and the stated warranty term is 10 years.