Deye BOS-A
A high-voltage rack battery built from 7.68 kWh LiFePO4 modules, seven to twenty-one in series, delivering 53.76 to 161.28 kWh per rack for commercial systems.
Technical Specifications
| Parameter | DEYE-BOS-A |
|---|---|
| Battery Data | |
| Energy | 7.68 kWh |
| Usable Energy | 48.38-145.15 kWh |
| Module Energy | 7.68 kWh |
| System Energy | 53.76-161.28 kWh |
| Nominal Voltage | 38.4 V |
| Module Nominal Voltage | 38.4 V |
| System Nominal Voltage | 268.8-806.4 V |
| Operating Voltage | 235.2-919.8 V |
| Rated Capacity | 200 Ah |
| Module Capacity | 200 Ah |
| Cell Chemistry | LiFePO4 |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70% |
| Recommended Depth of Discharge | 90% |
| Max. Charge Current | 160 A |
| Max. Discharge Current | 160 A |
| Max. Charge/Discharge Current | 160 A |
| Nominal Charge/Discharge Current | 160 A |
| Recommended Charge/Discharge Current | 100 A |
| Modules in Series | 7-21 |
| Min. Battery Module Quantity | 7 |
| Battery Module Models | BOS-A100, BOS-A160 |
| Parallel Units | 16 |
| Protection Features | Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing |
| Warranty (Years) | 10 |
| Mechanical & Interface | |
| Communication Ports | CAN2.0 |
| Dimensions | 610 x 1900 x 610 mm |
| Additional Notes | Two inverter DC interfaces; 50-100kW hybrid inverters; up to 10 inverters AC parallel; PDU BOS-A-PDU-2, module BOS-A-Pack7.68 |
| Module Dimensions | 601.5 x 135 x 520 mm |
| Module Weight | 70 kg |
| Status Indicator | Yellow: Battery High Voltage Power On; Red: Battery System Alarm |
| Weight | 525-1501 kg |
| Environment & Protection | |
| Altitude | <3000 m |
| Charge Temperature | 0-55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-85% |
| Installation Location | Rack-Mounted (3U) |
| Enclosure IP Rating | IP20 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge: 0-55 / Discharge: -20 to 55 °C |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Yemen
| Market | Yemen |
| Grid authority / regulator | Public Electricity Corporation (PEC), Ministry of Electricity and Energy |
| Quotation currency | YER |
| Support hours timezone | Asia/Aden |
| Delivery & installation coverage | Sana'a, Aden, Taiz, Al Hudaydah, Mukalla |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 7.68 kWh building blocks: Each BOS-A-Pack7.68 module holds 7.68 kWh at 38.4 V with a 200 Ah rating.
- Up to 161.28 kWh per rack: Seven to twenty-one modules in series span 53.76 to 161.28 kWh, of which 48.38 to 145.15 kWh is usable at 90% depth of discharge.
- Made for 50-100 kW hybrids: The BOS-A-PDU-2 exposes two DC interfaces sized for 50-100 kW hybrid inverters, with up to 10 inverters in AC parallel.
- Five-way BMS protection: Guards against over-charge, over-discharge, over-current and temperature faults, with active cell balancing.
- Parallelism at fleet scale: Up to 16 racks coordinate over CAN2.0 as one storage plant.
- Endurance past 6,000 cycles: LiFePO4 cells rated beyond 6,000 cycles to 70% end-of-life, under a 10-year warranty.
Frequently Asked Questions
What voltage class is the BOS-A?
It is a high-voltage system: 268.8 to 806.4 V nominal depending on module count, with an operating window of 235.2 to 919.8 V, so it belongs with high-voltage battery inverters.
Which inverter sizes suit the BOS-A?
The PDU (BOS-A-PDU-2) provides two DC interfaces intended for 50-100 kW hybrid inverters, and up to 10 inverters can run in AC parallel on larger sites.
How much energy can one BOS-A rack hold?
Between 53.76 and 161.28 kWh depending on whether 7 or 21 modules are fitted, with 48.38 to 145.15 kWh usable at 90% depth of discharge; 16 racks can be paralleled beyond that.
Where should a BOS-A be installed?
Indoors: the enclosure is rated IP20 and rack-mounted in 3U module format, measuring 610 x 1900 x 610 mm and weighing 525 to 1,501 kg depending on configuration.
What lifetime and warranty does the BOS-A carry?
Cycle life exceeds 6,000 cycles to 70% end-of-life capacity, and the stated warranty term is 10 years.