Deye DGA1-DC48V-12/18/24/09K

A 12,000 BTU battery-fed split for rooms of 12 to 20 m², wired to a 48 V bank and drawing 980 W at T1 with an EER of 3.60/12.25.

Models Covered: DGA1-DC48V-12K, DGA1-DC48V-18K, DGA1-DC48V-24K, DGA1-DC48V-09K

Manufacturer: Ningbo Deye Inverter Technology Co., Ltd

Application: The DGA1-DC48V-12K is the size most off-grid houses need first: 12,000 BTU for a room of 12 to 20 m², wired to nothing but a 48 V battery bank working between 46 and 58 V DC. Because the supply is stored energy, the unit is as useful at two in the morning as at noon, which is the practical difference between this model and a PV-direct machine. It produces 3,510 W of cooling at T1 for 980 W drawn, an EER of 3.60/12.25, and turns down to 200 W when the room is settled. Under T3 conditions output is 9,900 BTU. Heating is rated 13,300 BTU with 1,130 W of input, a COP of 3.45/11.75, and the coil removes 1.3 L/h of moisture. A GMCC ASN98D22UFZ rotary variable-speed compressor works a two-row coil, the outdoor fan moves 2,100 m³/h, and the pair weighs 32 kg net.

Technical Specifications

Technical Specifications
Parameter DGA1-DC48V-12KDGA1-DC48V-18KDGA1-DC48V-24KDGA1-DC48V-09K
Performance & Electrical
Battery Voltage 48 V
Compressor Brand GMCCHIGHLYPanasonicGMCC
Compressor Configuration Rotary Inverter2xRotary Inverter2xRotary InverterRotary Inverter
Compressor Model ASN98D22UFZWHP056005RD198ASK89D53UEZ
Cooling Capacity 12000 (3400-12600) BTU17300 (4100-18000) BTU22000 (8500-23900) BTU9000 (3400-11600) BTU
Cooling Capacity (T1) 3510 (1000-3700) W5070 (1200-5250) W6450 (2500-7000) W2600 (1000-3400) W
Cooling Capacity (T3) 2910 BTU4200 BTU5370 BTU2490 BTU
Cooling Power Input (T1) 980 (200-1200) W1450 (220-1780) W1840 (450-2230) W680 (180-1060) W
Cooling Power Input (T3) 1090 W1660 W2200 W960 W
Coefficient of Performance (COP) 3.45/11.753.75/12.803.40/11.703.50/11.90
DC Power Supply 46-58
Dehumidification 1.3 L/h1.7 L/h2.5 L/h1 L/h
EER (T1) 3.60/12.253.50/11.803.50/11.853.90/13.20
EER (T3) 2.65/9.052.55/8.602.45/8.302.60/8.90
Electronic Expansion Valve Yes
Heating Capacity 13300 (3400-14000) BTU18000 (4100-18700) BTU24000 (10200-25000) BTU9900 (2700-10400) BTU
Rated Heating Capacity 3900 (1000-4100) W5250 (1200-5500) W7000 (2000-7350) W2900 (800-3050) W
Heating Power Input 1130 (180-1280) W1400 (220-1830) W2050 (390-2350) W830 (160-950) W
Indoor Airflow 540/485/435/350 m³/h980/880/740/620 m³/h1290/1180/1070/900 m³/h485/435/380/305 m³/h
Indoor Fan Motor BLDC 15WBLDC 45WBLDC 45WBLDC 15W
Outdoor Airflow 2100 m³/h2200 m³/h3300 m³/h2000 m³/h
Outdoor Coil Rows 2221
Outdoor Coil Tube 7, Innergroove Tube9.52, Innergroove Tube9.52, Innergroove Tube7, Innergroove Tube
Outdoor Fan Motor BLDC 40WBLDC 55WBLDC 75WBLDC 40W
Outdoor Fan Speed 880 rpm880 rpm850 rpm880 rpm
Power Supply Battery
Refrigerant R410A
Mechanical & Installation
Connection Wire Length 4 m5 m5 m4 m
Container Loading Quantity 200/85160/75115/50200/85
Dimensions 900 x 700 x 337 mm
Drain Pipe Size 16 mm
Indoor Unit Dimensions 840 x 205 x 295 mm1080 x 330 x 237 mm1080 x 330 x 237 mm840 x 205 x 295 mm
Indoor Unit Packing Dimensions 920 x 290 x 360 mm1140 x 300 x 382 mm1140 x 300 x 382 mm920 x 290 x 360 mm
Indoor Unit Weight 9/12.5 kg15/18.5 kg15/18.5 kg9/12.5 kg
Max. Level Difference 8 m10 m10 m8 m
Max. Pipe Length 15 m20 m25 m15 m
Outdoor Unit Packing Dimensions 910 x 622 x 405 mm910 x 622 x 405 mm1006 x 755 x 418 mm910 x 622 x 405 mm
Refrigerant Pipe (Gas/Liquid) 3/8, 1/4 in1/2, 1/4 in1/2, 1/4 in3/8, 1/4 in
Supplied Pipe Length 3 m4 m4 m3 m
Weight 32/36 kg36/40 kg51/56 kg28/32 kg
Environment & Acoustics
Climate Type T1/T3
Indoor Noise Level <42.5 dB<46 dB<50 dB<40 dB
Max. Design Pressure 4.3/1.5 MPa4.3/1.5 MPa4.3/1.1 MPa4.3/1.5 MPa
Operating Temperature -10 to 58 °C
Outdoor Noise Level <52 dB<55 dB<58 dB<51 dB

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Oman

Market Oman
Grid authority / regulator Authority for Electricity Regulation Oman
Quotation currency OMR
Support hours timezone Asia/Muscat
Delivery & installation coverage Muscat, Salalah, Sohar

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Oman that is Authority for Electricity Regulation Oman. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • 48 V bank, 46-58 V DC: The unit is powered by the battery directly, so it keeps cooling after dark on stored charge instead of waiting for the array.
  • 12,000 BTU from the bank: 3,510 W of cooling at T1 for 980 W drawn, an EER of 3.60/12.25, with the range running from 3,400 to 12,600 BTU.
  • GMCC ASN98D22UFZ compressor: A rotary variable-speed compressor on a two-row coil with 7 mm inner-groove tube, metered by an electronic expansion valve on R410A.
  • 1.3 L/h dehumidification: Condensate leaves through a 16 mm drain while the indoor fan steps between 350 and 540 m³/h, so humid nights stay comfortable.
  • 13,300 BTU of heating: Rated 3,900 W of heat for 1,130 W of input at a COP of 3.45/11.75, across the same -10 to 58 °C operating range.
  • Fed by the battery alone: A 48 V bank between 46 and 58 V DC is the whole electrical installation, so cooling continues overnight without mains or a generator.
  • 17,300 BTU off the battery: 5,070 W at T1 for 1,450 W of input, an EER of 3.50/11.80, with the compressor modulating from 4,100 up to 18,000 BTU.
  • COP of 3.75/12.80 in heating: The strongest heating efficiency in the DC48V line: 5,250 W of heat for 1,400 W drawn from the bank, or 18,000 BTU.
  • Twin-rotary Highly WHP05600: Two rotary stages on a variable-speed drive, a two-row coil in 9.52 mm inner-groove tube and an electronic expansion valve on R410A.
  • Four fan steps, 980 m³/h: A BLDC 45 W indoor fan gives four steps from 620 to 980 m³/h; the outdoor unit runs a BLDC 55 W motor at 880 rpm below 55 dB.
  • 22,000 BTU on battery power: The largest DC48V model still takes its entire supply from a 48 V bank between 46 and 58 V, with no AC connection in the installation.
  • Rated for 30-40 m²: 6,450 W of cooling at T1 for 1,840 W drawn, an EER of 3.50/11.85, modulating between 8,500 and 23,900 BTU as the room fills or empties.

Frequently Asked Questions

What does the DGA1-DC48V-12K connect to?

A 48 V battery bank, and nothing else. The supply window is 46 to 58 V DC, so the bank feeds the compressor without an inverter in the path.

What room size does the DGA1-DC48V-12K cover?

12 to 20 m². Below that the 9,000 BTU DGA1-DC48V-09K is the closer match; above 20 m² the 17,300 BTU DGA1-DC48V-18K takes the load.

How much battery current does it draw at part load?

Input power runs between 200 and 1,200 W in cooling, sitting at 980 W under T1 conditions and 1,090 W under T3. Sizing the bank around those figures is the usual practice.

Does it work in very hot weather?

It carries T1 and T3 climate ratings and an operating range of -10 to 58 °C. At T3 the unit gives 2,910 W, or 9,900 BTU, for 1,090 W of input, an EER of 2.65/9.05.

What are the pipe and wiring limits?

Refrigerant lines may run 15 m with an 8 m level difference, using 3/8 in gas and 1/4 in liquid pipe. Three metres of pipe and 4 m of connection wire ship with the unit.

How much battery power does the DGA1-DC48V-18K need?

In cooling it draws 220 to 1,780 W, sitting at 1,450 W under T1 and 1,660 W under T3, all of it from a 48 V bank held between 46 and 58 V DC.

What size room is the DGA1-DC48V-18K for?

20 to 30 m², which covers a living room or a two-bed room. Under 20 m² the 12,000 BTU DGA1-DC48V-12K is the closer fit, and above 30 m² the 22,000 BTU DGA1-DC48V-24K.

Why does this model heat better than the others?

Its rated heating COP is 3.75/12.80, the highest of the four, giving 5,250 W of heat for 1,400 W of input. Heating output spans 1,200 to 5,500 W.

What happens in T3 heat?

Output settles at 4,200 W, or 14,300 BTU, for 1,660 W of input, an EER of 2.55/8.60. The unit is rated for both T1 and T3 climates from -10 to 58 °C.

How far can the outdoor unit be placed?

Up to 20 m of refrigerant pipe with 10 m of level difference, on 1/2 in gas and 1/4 in liquid lines. Four metres of pipe and 5 m of wire are supplied, and the pair weighs 36 kg net.