Deye SUN-3-6-6-2K-G05P1/SUN-3.6K-G05P1-EU-AM2/SUN-4.2K-G04/SUN-4.2K-G05P1-EU-AM2/SUN-4.6K-G04/SUN-4.6K-G05P1-EU-AM2/SUN-4K-G04/SUN-4K-G05P1-EU-AM2/SUN-5.2K-G04/SUN-5.2K-G05P1-EU-AM2/SUN-5K-G04/SUN-5K-G05P1-EU-AM2/SUN-6.2K-G04/SUN-6.2K-G05P1-EU-AM2/SUN-6K-G04/SUN-6K-G05P1-EU-AM2
3.6-6.2kW Single Phase String Inverter for residential and commercial solar installations.
Technical Specifications
| Parameter | DEYE-SUN-3-6-6-2K-G05P1 | SUN-3.6K-G05P1-EU-AM2 | SUN-4.2K-G04 | SUN-4.2K-G05P1-EU-AM2 | SUN-4.6K-G04 | SUN-4.6K-G05P1-EU-AM2 | SUN-4K-G04 | SUN-4K-G05P1-EU-AM2 | SUN-5.2K-G04 | SUN-5.2K-G05P1-EU-AM2 | SUN-5K-G04 | SUN-5K-G05P1-EU-AM2 | SUN-6.2K-G04 | SUN-6.2K-G05P1-EU-AM2 | SUN-6K-G04 | SUN-6K-G05P1-EU-AM2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Additional Specifications | ||||||||||||||||
| Rated output voltage | 220/230 | |||||||||||||||
| Max PV Voltage | 550 V | |||||||||||||||
| No. of Strings MPP Tracker | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 |
| No. of MPP Trackers/ No. of Strings MPP Tracker | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 1/1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 |
| Grid Connection Form | L/N/PE | L/N/PE | L/N/PE | L/N/PE | L/N/PE | L/N/PE | L+N+PE | L/N/PE | L+N+PE | L+N+PE | L/N/PE | L/N/PE | L/N/PE | L/N/PE | L/N/PE | L/N/PE |
| Island Protection Monitoring | Yes | |||||||||||||||
| MPPT Voltage Range | 70-500 V | |||||||||||||||
| Max. AC Output Apparent Power | 6.6 kVA | 3.96 kVA | 4.62 kVA | 4.62 kVA | 5.06 kVA | 5.06 kVA | 4.4 kVA | 4.4 kVA | 5.72 kVA | 5.72 kVA | 5.5 kVA | 5.5 kVA | 6.82 kVA | 6.82 kVA | 6.6 kVA | 6.6 kVA |
| Max. AC Output Current | 30/28.7 A | 18/17.3 A | 21/20.1 A | 21/20.1 A | 23/22 A | 23/22 A | 20/19.2 A | 20/19.2 A | 26/24.9 A | 26/24.9 A | 25/24 A | 25/24 A | 31/29.7 A | 31/29.7 A | 30/28.7 A | 30/28.7 A |
| Max. Input Short Circuit Current | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 30 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A | 27+27 A |
| Max. Inverter Backfeed Current To the Array | 0 | |||||||||||||||
| Max. Operating PV Input Current | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 20 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A | 18+18 A |
| Max. PV Input Power | 7.8 kW | 4.7 kW | 5.5 kW | 5.5 kW | 6 kW | 6 kW | 5.2 kW | 5.2 kW | 6.8 kW | 6.8 kW | 6.5 kW | 6.5 kW | 8.1 kW | 8.1 kW | 7.8 kW | 7.8 kW |
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||||||||||||||
| Overvoltage Load Drop Protection | Yes | |||||||||||||||
| Power Network Monitoring | Yes | |||||||||||||||
| Rated Output Voltage/Range | 220/230 0.85Un-1.1Un V | |||||||||||||||
| Rated PV Input Voltage | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 420 V | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V | 360 V |
| Residual Current (RCD) Detection | Yes | |||||||||||||||
| Ingress Protection(IP) Rating | IP 65 | |||||||||||||||
| Permissible Altitude | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 2000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m |
| AC Output Short Circuit Protection | — | Yes | — | — | — | — | yes | Yes | — | — | — | — | — | Yes | — | Yes |
| DC Polarity Reverse Connection Protection | Yes | |||||||||||||||
| DC Terminal Insulation Impedance Monitoring | Yes | |||||||||||||||
| Earth Fault Detection | Yes | |||||||||||||||
| Max. Input Short Circuit Current (A) | 27+27 | |||||||||||||||
| Max. Operating PV Input Current(A) | 18+18 | |||||||||||||||
| Max. Output Overcurrent Protection (A) | 75 | |||||||||||||||
| PV Input Voltage Range(V) | 80-550 | |||||||||||||||
| Rated Output voltage/range (V) | 220/230V 0.85Un-1.1Un | |||||||||||||||
| Ground Fault Current Monitoring | Yes | |||||||||||||||
| Rated AC Input/Output Active Power | 3600 W | |||||||||||||||
| Max. AC Input/Output Apparent Power | 3960 VA | |||||||||||||||
| Rated AC Input/Output Current | 16.4/15.7 A | |||||||||||||||
| Max. AC Input/Output Current | 18/17.2 A | |||||||||||||||
| Insulation Impedance detection | Yes | |||||||||||||||
| Permissible Altitude (m) | 3000m | |||||||||||||||
| Weight [kg] | 5.6 | |||||||||||||||
| Electrical Data | ||||||||||||||||
| No. of MPP Trackers | 2 | — | — | — | — | — | 1 | — | — | — | — | — | — | — | — | — |
| Full Load MPPT Voltage Range | 215-500 V | 130-500 V | 150-500 V | 150-500 V | 165-500 V | 165-500 V | 360-500 V | 145-500 V | 190-500 V | 190-500 V | 180-500 V | 180-500 V | 225-500 V | 225-500 V | 215-500 V | 215-500 V |
| Max. Output Fault Current | 52.2 A | 31.4 A | 36.6 A | 36.6 A | 40 A | 40 A | 34.8 A | 34.8 A | 45.4 A | 45.4 A | 43.6 A | 43.6 A | 54 A | 54 A | 52.2 A | 52.2 A |
| MPPT Voltage Range (V) | 70-500 | |||||||||||||||
| Max. AC Output Apparent Power (KVA) | — | 3.96 | — | — | — | 5.06* | — | 4.4 | — | — | — | — | — | 6.82 | — | 6.6 |
| Max. AC Output Current (A) | — | 18.0/17.3 | — | — | — | 23.0/22.0 | — | 20/19.2 | — | — | — | — | — | 31/29.7 | — | 30/28.7 |
| Max. PV Input Power (kW) | — | 5.4 | — | — | — | 6.9 | — | 5.2 | — | — | — | — | — | 8.1 | — | 7.8 |
| Max. PV Input Voltage (V) | 550 | |||||||||||||||
| Rated AC Output Active Power (kW) | — | 3.6 | — | — | — | 4.6 | — | 4 | — | — | — | — | — | 6.2 | — | 6 |
| Rated AC Output Current (A) | — | 16.4/15.7 | — | — | — | 21.0/20.0 | — | 18.2/17.4 | — | — | — | — | — | 28.2/27 | — | 27.3/26.1 |
| Rated PV Input Voltage (V) | 360 | |||||||||||||||
| Start-up Voltage (V) | 80 | |||||||||||||||
| PV Input Voltage Range | 80-550 V | |||||||||||||||
| DC Switch | yes | |||||||||||||||
| PV Connection | VP-D4 | |||||||||||||||
| Rated Output voltage/range (V) 230V | 0.85Un-1.1Un | |||||||||||||||
| Communication | ||||||||||||||||
| Communication Interface | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 | RS485/RS232 /WiFi/LAN | RS485/RS232 | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN | RS485/RS232 /WiFi/LAN |
| Electrical / AC Output Data | ||||||||||||||||
| Euro Efficiency | 97.0% | 96.9% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 96.9% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% |
| Topology | Non-Isolated | |||||||||||||||
| Max Efficiency | 97.5% | 97.3% | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% | 97.3% | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% | 97.5% |
| Adjustable Power Factor Range | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading-O.8lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
| Rated AC Output Active Power | 6 kW | 3.6 kW | 4.2 kW | 4.2 kW | 4.6 kW | 4.6 kW | 4 kW | 4 kW | 5.2 kW | 5.2 kW | 5 kW | 5 kW | 6.2 kW | 6.2 kW | 6 kW | 6 kW |
| Rated AC Output Current | 27.3/26.1 A | 16.4/15.7 A | 19.1/18.3 A | 19.1/18.3 A | 21/20 A | 21/20 A | 16.4/15.7 18.2/17.4 A | 18.2/17.4 A | 23.7/22.7 A | 23.7/22.7 A | 22.8/21.8 A | 22.8/21.8 A | 28.2/27 A | 28.2/27 A | 27.3/26.1 A | 27.3/26.1 A |
| Grid / AC Frequency | 50/45-55, 60/55-65 Hz | |||||||||||||||
| THD / THDi | <3% | |||||||||||||||
| Rated Power | 3.6-6.2kW | |||||||||||||||
| Phase | Single Phase | Single-phase | — | Single-phase | — | Single-phase | — | Single-phase | — | Single-phase | — | Single-phase | — | Single-phase | — | Single-phase |
| Full Load MPPT Voltage Range(V) | — | 130-500 | — | — | — | 165-500 | — | — | — | — | — | — | — | — | — | — |
| Max. Output Fault Current(A) | — | 31.4 | — | — | — | 40 | — | — | — | — | — | — | — | — | — | — |
| Rated Output Grid Frequency/range(Hz) | 50Hz/45Hz-55Hz, 60Hz/55Hz-65Hz | |||||||||||||||
| Rated AC Power | — | 3.6 kW | 4.2 kW | 4.2 kW | 4.6 kW | 4.6 kW | 4 kW | 4 kW | 5.2 kW | 5.2 kW | 5 kW | 5 kW | 6.2 kW | 6.2 kW | 6 kW | 6 kW |
| Max Operating Current | — | 18+18 A | 13+13 A | 18+18 A | 13+13 A | 18+18 A | 13+13 A | 18+18 A | 13+13 A | 18+18 A | 13+13 A | 18+18 A | 13+13 A | 18+18 A | 13+13 A | 18+18 A |
| DC Injection Current | — | <0.5%ln | — | — | — | <0.5%In | <0.5%ln | — | — | — | — | — | — | — | — | — |
| Euro Efficiency 96.90% | 97.00% | |||||||||||||||
| Max.Efficiency 97.30% | 97.50% | |||||||||||||||
| Protection Features | ||||||||||||||||
| Grid Connection Standards | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IECUNE61727,217002,IEC62116,OVE-RichtlinieCEI0-21, ENR25,50549,G99,VDE-AR-NNRS097,RD4105140, | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IECUNE61727,217002,IEC62116,OVE-RichtlinieCEI0-21, ENR25,50549,G99,VDE-AR-NNRS097,RD4105140, | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 | IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99 |
| Over-Current Protection | Yes | Yes | Yes | Yes | Yes | Yes | yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Overvoltage Category | OVC II(DC), OVC III(AC) | |||||||||||||||
| Safety / EMC Standards | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||||||||||||||
| AC/DC Surge Protection | TYPE II(DC), TYPE II(AC) | |||||||||||||||
| Over-Temperature / Thermal Protection | Yes | |||||||||||||||
| IP Rating | IP65 | |||||||||||||||
| Over-Voltage Protection | — | Yes | — | — | — | — | yes | Yes | — | — | — | — | — | Yes | — | Yes |
| DC Component Monitoring | — | Yes | — | — | — | — | yes | Yes | — | — | — | — | — | Yes | — | Yes |
| DC Reverse Polarity Protection | — | Yes | — | — | — | — | yes | — | — | — | — | — | — | — | — | — |
| PV String Input Data | ||||||||||||||||
| MPPT Efficiency | >99% | |||||||||||||||
| Max. PV Input Voltage | 550 V | |||||||||||||||
| Start-up Voltage | 80 V | |||||||||||||||
| Number of MPP Trackers | 2 | |||||||||||||||
| Max PV Input Current | 13+13 A | |||||||||||||||
| Mechanical Data | ||||||||||||||||
| Cooling Method | Natural cooling | |||||||||||||||
| Cooling | Natural Cooling | |||||||||||||||
| Operating Conditions | ||||||||||||||||
| Noise Level | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤ 35dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB | ≤35 dB |
| Operating Temperature Range | -25 to +60℃, >45℃ Derating °C | |||||||||||||||
| Relative Humidity | 0-100% | |||||||||||||||
| Operating Temperature | -25 to +60 °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +65℃,>45℃ derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C | -25 to +60℃, >45℃ Derating °C |
| General Data | ||||||||||||||||
| Inverter Type | String Inverter | |||||||||||||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in Sudan
| Market | Sudan |
| Grid authority / regulator | Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum |
| Quotation currency | SDG |
| Support hours timezone | Africa/Khartoum |
| Delivery & installation coverage | Khartoum, Omdurman, Port Sudan, Kassala, Nyala |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Sudan that is Sudanese Electricity Distribution Company (SEDC), Ministry of Energy and Petroleum. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- 3.6-6.2kW Output: High efficiency power conversion
- Wide MPPT Range: Optimized for various solar configurations
- IP65 Protection: Suitable for outdoor installation
- Smart Monitoring: Real-time performance tracking
- 97.5% Efficiency: High energy conversion
- Dual MPPT: Two independent trackers
- 80V Start-up: Works in low-light conditions
- Zero Export: Manage grid export limits
- Anti-PID: Prevents panel degradation
- Multiple Comms: GPRS, WiFi, Bluetooth, 4G, LAN
Frequently Asked Questions
Is the DEYE SUN-3-6-6-2K-G05P1 suitable for the Middle East climate?
Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
What is the warranty period?
This inverter comes with a 5-year standard warranty, with options for extended warranty available.
Can this be used for off-grid systems?
This is primarily designed for grid-tied systems. For off-grid applications, consider our hybrid inverter range.
Why does this model have dual MPPT?
Dual MPPT trackers allow the inverter to independently optimize power from two separate strings of solar panels, maximizing energy output even with different orientations or partial shading.
What is the Anti-PID function?
The optional Anti-PID function helps prevent Potential Induced Degradation of solar panels, maintaining high efficiency over the system's lifespan.
What is the maximum PV input?
The SUN-3.6K supports up to 4.7kW PV input, while the SUN-6.2K supports up to 8.06kW, allowing for high DC/AC ratios.
Is this suitable for commercial use?
Yes! With power ratings from 3.6kW to 6.2kW and advanced features like zero export and VSG support, it's suitable for both residential and commercial installations.