Deye MJS Solutions

Deye SUN-10/12/15/3/4/5/6/7/8/9K-G06P3-EU-AM2-P1

10kW three phase string inverter (P1) with 98.5% efficiency and dual MPPT.

Models Covered: SUN-10K-G06P3-EU-AM2-P1, SUN-12K-G06P3-EU-AM2-P1, SUN-15K-G06P3-EU-AM2-P1, SUN-3K-G06P3-EU-AM2-P1, SUN-4K-G06P3-EU-AM2-P1, SUN-5K-G06P3-EU-AM2-P1, SUN-6K-G06P3-EU-AM2-P1, SUN-7K-G06P3-EU-AM2-P1, SUN-8K-G06P3-EU-AM2-P1, SUN-9K-G06P3-EU-AM2-P1

Manufacturer: Ningbo Deye Technology Co., Ltd.

Application: The Deye SUN-10K-G06P3-EU-AM2-P1 series delivers cutting-edge technology for modern solar energy systems. With 10kW power range, 98.5% max efficiency, 97.5-98% European efficiency, dual MPPT trackers, up to 1100V PV voltage, zero export and VSG support, Anti-PID function, and IP65 protection, it's designed for high efficiency and reliability.

Technical Specifications

Technical Specifications
Parameter SUN-10K-G06P3-EU-AM2-P1SUN-12K-G06P3-EU-AM2-P1SUN-15K-G06P3-EU-AM2-P1SUN-3K-G06P3-EU-AM2-P1SUN-4K-G06P3-EU-AM2-P1SUN-5K-G06P3-EU-AM2-P1SUN-6K-G06P3-EU-AM2-P1SUN-7K-G06P3-EU-AM2-P1SUN-8K-G06P3-EU-AM2-P1SUN-9K-G06P3-EU-AM2-P1
Additional Specifications
Full Load MPPT Voltage Range(V) 480-850
MPPT Voltage Range(V) 120-1000
Max. Input Short Circuit Current (A) 30+30
Max. Operating PV Input Current(A) 20+20
Max. PV Input Voltage(V) 1100
No. of MPP Trackers/No. of Strings per MPP Tracker 2/1+1
Rated AC Output current (A) 15.2/14.518.2/17.410.7/10.212.2/11.613.7/13.1
Rated PV Input Voltage(V) 600
Grid Connection Form 3L/N/PE3L/N/PE3L/N/PE3L/N/PE3L+N+PE3L/N/PE3L/N/PE3L/N/PE3L/N/PE3L/N/PE
Over-Current Protection YesyesYesYesyesYesYesYesYesYes
Island Protection Monitoring Yes
Max. Input Short Circuit Current 30+39 A30+39 A30+39 A30+30 A30+30 A30+30 A30+30 A30+30 A30+30 A30+30 A
Max. Operating PV Input Current 20+26 A20+26 A20+26 A20+20 A20+20 A20+20 A20+20 A20+20 A20+20 A20+20 A
Overvoltage Load Drop Protection YesYesYesYesyesYesYesYesYesYes
Power Network Monitoring YesYesYesYesyesYesYesYesYesYes
Residual Current (RCD) Detection YesYesYesYesyesYesYesYesYesYes
Total Current Harmonic Distortion THDi <3%
Max PV Voltage 1100 V
Max. Continuous AC Passthrough (grid to load) 45 A
Ingress Protection(IP) Rating IP 65
Noise <45 dB<45 dB<45 dB<45 dB<45 dB<45 dB<45 dB<45 dB<45 dB<45 dB
Operating Temperature Range -25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃,>45℃ derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C-25 to +60℃, >45℃ Derating °C
Permissible Altitude 4000 m
Over-Voltage Protection Yesyes
Max. Inverter Backfeed Current To the Array 0
DC Input Switch yes
Ground Fault Current Monitoring Yes
AC Output Short Circuit Protection yes
Electrical / AC Output Data
Max. PV Input Power(kW) 1315.69.110.411.7
Max.AC Output Apparent Power(kVA) 1113.27.78.89.9
Max.AC Output Current(A) 16.7/16.020/19.211.7/11.213.4/12.815/14.4
Rated AC Output Active Power(kW) 1012789
PV Input Voltage Range 140-1100 V140-1100 V140-1100 V140-1100 V140-1100 V140-1100 V250-800 V140-1100 V250-800 V140-1100 V
AC Grid Connection Type String Inverter
No. of Strings MPP Tracker 1+21+21+21+11+11+11+11+11+11+1
No. of MPP Trackers/ No. of Strings MPP Tracker 2/1+22/1+22/1+22/1+12/1+12/1+12/1+12/1+12/1+12/1+1
Euro Efficiency 97.8%98%98%97.5%97.5%97.6%97.6%97.6%97.8%97.8%
Topology Non-Isolated
Max. AC Output Current 16.7/16 A20/19.2 A25/24 A5/4.8 A6.7/6.4 A8.4/8 A10/9.6 A11.7/11.2 13.4/12.8 A11.7/11.2 13.4/12.8 A15/14.4 A
Max. PV Input Power 15 kW18 kW22.5 kW4.5 kW6 kW7.5 kW9 kW10.5 kW12 kW13.5 kW
Adjustable Power Factor Range 0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading-0.8lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging
Rated AC Output Current 10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A4.6/4.4 A6.1/5.8 A7.6/7.3 A9.1/8.7 A10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A10.7/10.2 12.2/11.6 13.7/13.1 15.2/14.5 18.2/17.4 22.8/21.8 A
Grid / AC Frequency 50/45-55, 60/55-65 Hz
Output Voltage Range 220/380V, 230/400V 0.85Un-1.1Un
Rated AC Power 10 kW12 kW15 kW3 kW4 kW5 kW6 kW7 kW8 kW9 kW
European Efficiency 97.8%97.8%98.0%97.5%97.5%97.6%97.6%97.8%97.8%97.8%
THD / THDi <3%
Nominal AC Voltage 220/380V, 230/400V
Rated AC Input/Output Active Power 10000 W12000 W
Max. AC Input/Output Apparent Power 11000 VA13200 VA
Rated AC Input/Output Current 15.2/14.5 A18.2/17.4 A
Max. AC Input/Output Current 16.7/15.9 A20/19.1 A
Max. Three-phase Unbalanced Output Current 22.7/21.7 A27.3/26.1 A
Max. Output Fault Current 33.4 A40 A43.6 A8.8 A11.6 A14.6 A30.2 A
Max. Output Overcurrent Protection 70 A70 A47.7 A47.7 A47.7 A47.7 A47.7 A47.7 A
DC Injection Current <0.5%In<0.5%ln<0.5%In<0.5%In<0.5%In
DC Polarity Reverse Connection Protection Yesyesyes
DC Terminal Insulation Impedance Monitoring YesYesyes
Phase Three-phaseC current =5.002AThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phase
Electrical Data
Max. Efficiency 98.3%98.5%98.5%98.1%98.1%98.2%98.2%98.2%98.3%98.3%
Start-up Voltage(V) 140
Full Load MPPT Voltage Range 480-850 V480-850 V480-850 V350-850 V350-850 V350-850 V350-850 V480-850 V480-850 V480-850 V
Max. AC Output Apparent Power 11 kVA13.2 kVA16.5 kVA3.3 kVA4.4 kVA5.5 kVA6.6 kVA7.7 kVA8.8 kVA9.9 kVA
Rated AC Output Active Power 10 kW12 kW15 kW3 kW4 kW5 kW6 kW7 kW8 kW9 kW
Communication
Communication Interface RS485/RS232
Monitoring Module GPRS/WIFI/Bluetooth/4G/LAN(optional)
Protection Features
Grid Connection Standards IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116, EN 50549IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,IEC 61727, IEC 62116,OVE-RichtlinieCEI0-21,R25,EN50549,G99,VDE-AR-NNRS097,RD4105140, UNE 217002,
Overvoltage Category OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)OVC II(DC), OVC III(AC)
Safety / EMC Standards IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
AC/DC Surge Protection TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)TYPEII(DC),TYPEII(AC)TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)TYPE II(DC), TYPE II(AC)
Over-Temperature / Thermal Protection YesYesYesYesyesYesYesYesYesYes
IP Rating IP65
DC Component Monitoring yes
PV String Input Data
MPPT Efficiency >99%
MPPT Voltage Range 120-1000 V
Max. PV Input Voltage 1100 V
Rated PV Input Voltage 600 V
Start-up Voltage 140 V
Number of MPP Trackers 2
Mechanical Data
Type Of Cooling Natural coolingNatural coolingIntelligent air coolingNatural CoolingNatural coolingNatural coolingNatural coolingNatural CoolingNatural CoolingNatural cooling
Cooling Natural CoolingNatural CoolingIntelligent Air CoolingNatural CoolingNatural CoolingNatural CoolingNatural CoolingNatural CoolingNatural CoolingNatural Cooling
Operating Conditions
Noise Level <45 dB
Relative Humidity 0-100%
Operating Temperature -25 to 60 °C
Max Altitude 4000 m

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in Yemen

Market Yemen
Grid authority / regulator Public Electricity Corporation (PEC), Ministry of Electricity and Energy
Quotation currency YER
Support hours timezone Asia/Aden
Delivery & installation coverage Sana'a, Aden, Taiz, Al Hudaydah, Mukalla

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in Yemen that is Public Electricity Corporation (PEC), Ministry of Electricity and Energy. Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

Key Features & Technical Highlights

  • 98.5% Efficiency: Maximum energy conversion
  • Dual MPPT: Two independent trackers
  • 1100V PV Input: High voltage compatibility
  • Zero Export: Grid export management
  • VSG Support: Virtual Synchronous Generator
  • Smart Monitoring: Optional string monitoring

Frequently Asked Questions

Is the DEYE SUN-10K-G06P3-EU-AM2-P1 suitable for the Middle East climate?

Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.

What makes this the P1 version?

The P1 version features enhanced specifications and is designed for optimal performance across a wide range of applications, with support for both residential and commercial installations.

What is the maximum PV input?

The SUN-3K supports 4.5kW PV input, while the SUN-15K supports up to 22.5kW, allowing for high DC/AC ratios and maximum energy harvest.