Deye DGA1-ACDCBLW-24K solar air conditioner

Deye DGA1-ACDCBLW-24K

The largest PV-direct ACDCBLW unit: 22,000 BTU for halls and showrooms of 30 to 42 m², on a three to eight panel string with a Panasonic 5RD198 compressor.

  • Cooling Capacity: 22000(6100-27000) BTU
  • EER (T1): 3.60/12.30
  • Coefficient of Performance (COP): 3.40/11.60
  • Power Supply: 1Ph 208-240V, 50/60Hz
2,572 AEDincl. VAT

In stock

This is our retail price in the UAE, Saudi Arabia and Syria, where we sell direct and deliver within 3 business days. Everywhere else it is a reference figure: those markets are supplied wholesale, at trade pricing with quantity terms, delivered in 15 business working days.

One unit:
order at this price and pay on delivery, or collect it free from one of our counters.
Installers:
trade pricing from pallet quantity, out of the same stock, with this unit’s datasheet and error codes.
Projects and businesses:
we quote from one piece to five hundred, and can size the system with you before you order.

Become our retailer in your country and get wholesale pricingSize the system for this unitPre-sized systems

Or collect it yourself — no carriage

Deye DGA1-ACDCBLW-24K features

22,000 BTU for 30-42 m²

6,450 W of cooling at T1 for 1,790 W drawn, an EER of 3.60/12.30, modulating from 6,100 up to 27,000 BTU as the hall fills.

Up to eight 330 W panels

The series string can run from three to eight modules inside the 80-380 V DC window, so a bigger roof buys more solar hours on the same unit.

2.5 L/h of dehumidification

The highest moisture removal in the ACDCBLW line, drained through a 16 mm pipe, which matters in coastal halls where the air is heavy.

Panasonic 5RD198 compressor

A twin-rotary variable-speed compressor paired with an electronic expansion valve, running R410A at a 4.3/1.5 MPa design pressure.

Pipe reach of 25 metres

The longest run in the family: the outdoor unit can sit 25 m away and 10 m below or above, on 1/2 in gas and 1/4 in liquid lines.

About the Deye DGA1-ACDCBLW-24K

With 22,000 BTU on tap, the DGA1-ACDCBLW-24K is the unit for the rooms the smaller models cannot hold: a 30 to 42 m² hall, a showroom floor or an open-plan office. Its DC input accepts three to eight 330 W modules in series between 80 and 380 V, so a larger roof translates directly into more hours of free cooling, while the 208-240 V single-phase side stands behind it with a 0-600 W limiter on what it may draw. Cooling is 6,450 W at T1 for 1,790 W of input, an EER of 3.60/12.30, and 17,500 BTU still comes out under T3 conditions. Heating reaches 26,600 BTU at a COP of 3.40/11.60. A Panasonic 5RD198 twin-rotary variable-speed compressor and a 3,300 m³/h outdoor coil carry the load, condensate leaves at 2.5 L/h, and the pair weighs 50 kg net, 54.5 kg packed.

Specifications last updated 24 January 2026

Deye DGA1-ACDCBLW-24K is best for

  • Halls, showrooms and open-plan offices of 30 to 42 m²
  • Roofs with room for up to eight 330 W modules in a string
  • Humid coastal buildings needing 2.5 L/h of moisture removal
  • Long installations, up to 25 m of pipe and 10 m of level difference
  • Sites that also want 26,600 BTU of heating from the same unit

Deye DGA1-ACDCBLW-24K is not for

  • Rooms under 30 m², where a smaller ACDCBLW model runs closer to its rating
  • Sites without a PV string: the DC feed is 80-380 V from panels, not a battery bank
  • Bedrooms with a strict noise limit, given the under 50 dB indoor rating
  • Two-person lifts without gear, at 50 kg net for the pair

Deye DGA1-ACDCBLW-24K full specifications

Electrical

AC Power Limiter0-600 W
Compressor BrandPanasonic
Compressor Configuration2xRotary Inverter
Compressor Model5RD198
Cooling Capacity22000(6100-27000) BTU
Cooling Capacity (T1)6450(1800-7900) W
Cooling Capacity (T3)17500 BTU
Cooling Capacity (T3)5130 W
Cooling Power Input (T1)1790(300-3200) W
Cooling Power Input (T3)1940 W
Coefficient of Performance (COP)3.40/11.60
DC Input Current<10 A
DC Power SupplyPV In Series
DC PV Voltage80-380 V
Dehumidification2.5 L/h
EER (T1)3.60/12.30
EER (T3)2.65/9.00
Electronic Expansion ValveYes
Heating Capacity26600 (6100-31000) BTU
Rated Heating Capacity7800(1800-9100) W
Heating Power Input2290(300-3500) W
Indoor Airflow1290/1180/1070/900 m³/h
Indoor Fan MotorBLDC 45W
Outdoor Airflow3300 m³/h
Outdoor Fan MotorBLDC 75W
Outdoor Fan Speed850 rpm
Power Supply1Ph 208-240V, 50/60Hz
Recommended PV Panels3-8
RefrigerantR410A
Solar Module Power330 W

Mechanical

Container Loading Quantity115/50
Dimensions900 x 700 x 337 mm
Drain Pipe Size16 mm
Indoor Unit Dimensions1080 x 330 x 237 mm
Indoor Unit Packing Dimensions1140 x 300 x 382 mm
Indoor Unit Weight15/18.5 kg
Max. Level Difference10 m
Max. Pipe Length25 m
Outdoor Unit Packing Dimensions1006 x 755 x 418 mm
Refrigerant Pipe (Gas/Liquid)1/2, 1/4 in
Supplied Pipe Length4 m
Weight50/54.5 kg

Environmental

Climate TypeT3/T1
Indoor Noise Level<50 dB
Max. Design Pressure4.3/1.5 MPa
Operating Temperature-10 to 58 °C
Outdoor Noise Level<58 dB

Related Products