Deye Solar Air Conditioner Datasheet — DGA1-DC48V-12K
A 12,000 BTU battery-fed split for rooms of 12 to 20 m², wired to a 48 V bank and drawing 980 W at T1 with an EER of 3.60/12.25.
SKU: DGA1-DC48V-12K | Last Updated: 2026-01-24
⚡Electrical Specifications
| Battery Voltage | 48 V |
| Compressor Brand | GMCC |
| Compressor Configuration | Rotary Inverter |
| Compressor Model | ASN98D22UFZ |
| Cooling Capacity | 12000 (3400-12600) BTU |
| Cooling Capacity (T1) | 3510 (1000-3700) W |
| Cooling Capacity (T3) | 9900 BTU |
| Cooling Capacity (T3) | 2910 W |
| Cooling Power Input (T1) | 980 (200-1200) W |
| Cooling Power Input (T3) | 1090 W |
| Coefficient of Performance (COP) | 3.45/11.75 |
| DC Power Supply | 46-58 |
| Dehumidification | 1.3 L/h |
| EER (T1) | 3.60/12.25 |
| EER (T3) | 2.65/9.05 |
| Electronic Expansion Valve | Yes |
| Heating Capacity | 13300 (3400-14000) BTU |
| Rated Heating Capacity | 3900 (1000-4100) W |
| Heating Power Input | 1130 (180-1280) W |
| Indoor Airflow | 540/485/435/350 m³/h |
| Indoor Fan Motor | BLDC 15W |
| Outdoor Airflow | 2100 m³/h |
| Outdoor Coil Rows | 2 |
| Outdoor Coil Tube | 7, Innergroove Tube |
| Outdoor Fan Motor | BLDC 40W |
| Outdoor Fan Speed | 880 rpm |
| Power Supply | Battery |
| Refrigerant | R410A |
🔧Mechanical Specifications
| Connection Wire Length | 4 m |
| Container Loading Quantity | 200/85 |
| Dimensions | 802 x 564 x 323 mm |
| Drain Pipe Size | 16 mm |
| Indoor Unit Dimensions | 840 x 205 x 295 mm |
| Indoor Unit Packing Dimensions | 920 x 290 x 360 mm |
| Indoor Unit Weight | 9/12.5 kg |
| Max. Level Difference | 8 m |
| Max. Pipe Length | 15 m |
| Outdoor Unit Packing Dimensions | 910 x 622 x 405 mm |
| Refrigerant Pipe (Gas/Liquid) | 3/8, 1/4 in |
| Supplied Pipe Length | 3 m |
| Weight | 32/36 kg |
🌡️Environmental Specifications
| Climate Type | T1/T3 |
| Indoor Noise Level | <42.5 dB |
| Max. Design Pressure | 4.3/1.5 MPa |
| Operating Temperature | -10 to 58 °C |
| Outdoor Noise Level | <52 dB |