Deye Solar Air Conditioner Datasheet — DGA1-DC48V-24K
The largest battery-fed Deye split: 22,000 BTU for 30-40 m² rooms on 46-58 V DC, drawing 1,840 W at T1 and clearing 2.5 L/h of humidity.
SKU: DGA1-DC48V-24K | Last Updated: 2026-01-24
⚡Electrical Specifications
| Battery Voltage | 48 V |
| Compressor Brand | Panasonic |
| Compressor Configuration | 2xRotary Inverter |
| Compressor Model | 5RD198 |
| Cooling Capacity | 22000 (8500-23900) BTU |
| Cooling Capacity (T1) | 6450 (2500-7000) W |
| Cooling Capacity (T3) | 18300 BTU |
| Cooling Capacity (T3) | 5370 W |
| Cooling Power Input (T1) | 1840 (450-2230) W |
| Cooling Power Input (T3) | 2200 W |
| Coefficient of Performance (COP) | 3.40/11.70 |
| DC Power Supply | 46-58 |
| Dehumidification | 2.5 L/h |
| EER (T1) | 3.50/11.85 |
| EER (T3) | 2.45/8.30 |
| Electronic Expansion Valve | Yes |
| Heating Capacity | 24000 (10200-25000) BTU |
| Rated Heating Capacity | 7000 (2000-7350) W |
| Heating Power Input | 2050 (390-2350) W |
| Indoor Airflow | 1290/1180/1070/900 m³/h |
| Indoor Fan Motor | BLDC 45W |
| Outdoor Airflow | 3300 m³/h |
| Outdoor Coil Rows | 2 |
| Outdoor Coil Tube | 9.52, Innergroove Tube |
| Outdoor Fan Motor | BLDC 75W |
| Outdoor Fan Speed | 850 rpm |
| Power Supply | Battery |
| Refrigerant | R410A |
🔧Mechanical Specifications
| Connection Wire Length | 5 m |
| Container Loading Quantity | 115/50 |
| Dimensions | 900 x 700 x 337 mm |
| Drain Pipe Size | 16 mm |
| Indoor Unit Dimensions | 1080 x 330 x 237 mm |
| Indoor Unit Packing Dimensions | 1140 x 300 x 382 mm |
| Indoor Unit Weight | 15/18.5 kg |
| Max. Level Difference | 10 m |
| Max. Pipe Length | 25 m |
| Outdoor Unit Packing Dimensions | 1006 x 755 x 418 mm |
| Refrigerant Pipe (Gas/Liquid) | 1/2, 1/4 in |
| Supplied Pipe Length | 4 m |
| Weight | 51/56 kg |
🌡️Environmental Specifications
| Climate Type | T1/T3 |
| Indoor Noise Level | <50 dB |
| Max. Design Pressure | 4.3/1.1 MPa |
| Operating Temperature | -10 to 58 °C |
| Outdoor Noise Level | <58 dB |