48 V bank, 46-58 V DC
The unit is powered by the battery directly, so it keeps cooling after dark on stored charge instead of waiting for the array.

Solar Air ConditionersModel DGA1-DC48V-12K
A 12,000 BTU battery-fed split for rooms of 12 to 20 m², wired to a 48 V bank and drawing 980 W at T1 with an EER of 3.60/12.25.
In stock
The unit is powered by the battery directly, so it keeps cooling after dark on stored charge instead of waiting for the array.
3,510 W of cooling at T1 for 980 W drawn, an EER of 3.60/12.25, with the range running from 3,400 to 12,600 BTU.
A rotary variable-speed compressor on a two-row coil with 7 mm inner-groove tube, metered by an electronic expansion valve on R410A.
Condensate leaves through a 16 mm drain while the indoor fan steps between 350 and 540 m³/h, so humid nights stay comfortable.
Rated 3,900 W of heat for 1,130 W of input at a COP of 3.45/11.75, across the same -10 to 58 °C operating range.
The DGA1-DC48V-12K is the size most off-grid houses need first: 12,000 BTU for a room of 12 to 20 m², wired to nothing but a 48 V battery bank working between 46 and 58 V DC. Because the supply is stored energy, the unit is as useful at two in the morning as at noon, which is the practical difference between this model and a PV-direct machine. It produces 3,510 W of cooling at T1 for 980 W drawn, an EER of 3.60/12.25, and turns down to 200 W when the room is settled. Under T3 conditions output is 9,900 BTU. Heating is rated 13,300 BTU with 1,130 W of input, a COP of 3.45/11.75, and the coil removes 1.3 L/h of moisture. A GMCC ASN98D22UFZ rotary variable-speed compressor works a two-row coil, the outdoor fan moves 2,100 m³/h, and the pair weighs 32 kg net. We are an authorised Deye distributor and supply the DGA1-DC48V-12K from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| Battery Voltage | 48 V |
|---|---|
| Compressor Brand | GMCC |
| Compressor Configuration | Rotary Inverter |
| Compressor Model | ASN98D22UFZ |
| Cooling Capacity | 12000 (3400-12600) BTU |
| Cooling Capacity (T1) | 3510 (1000-3700) W |
| Cooling Capacity (T3) | 9900 BTU |
| Cooling Capacity (T3) | 2910 W |
| Cooling Power Input (T1) | 980 (200-1200) W |
| Cooling Power Input (T3) | 1090 W |
| Coefficient of Performance (COP) | 3.45/11.75 |
| DC Power Supply | 46-58 |
| Dehumidification | 1.3 L/h |
| EER (T1) | 3.60/12.25 |
| EER (T3) | 2.65/9.05 |
|---|---|
| Electronic Expansion Valve | Yes |
| Heating Capacity | 13300 (3400-14000) BTU |
| Rated Heating Capacity | 3900 (1000-4100) W |
| Heating Power Input | 1130 (180-1280) W |
| Indoor Airflow | 540/485/435/350 m³/h |
| Indoor Fan Motor | BLDC 15W |
| Outdoor Airflow | 2100 m³/h |
| Outdoor Coil Rows | 2 |
| Outdoor Coil Tube | 7, Innergroove Tube |
| Outdoor Fan Motor | BLDC 40W |
| Outdoor Fan Speed | 880 rpm |
| Power Supply | Battery |
| Refrigerant | R410A |
| Connection Wire Length | 4 m |
|---|---|
| Container Loading Quantity | 200/85 |
| Dimensions | 802 x 564 x 323 mm |
| Drain Pipe Size | 16 mm |
| Indoor Unit Dimensions | 840 x 205 x 295 mm |
| Indoor Unit Packing Dimensions | 920 x 290 x 360 mm |
| Indoor Unit Weight | 9/12.5 kg |
| Max. Level Difference | 8 m |
|---|---|
| Max. Pipe Length | 15 m |
| Outdoor Unit Packing Dimensions | 910 x 622 x 405 mm |
| Refrigerant Pipe (Gas/Liquid) | 3/8, 1/4 in |
| Supplied Pipe Length | 3 m |
| Weight | 32/36 kg |
| Climate Type | T1/T3 |
|---|---|
| Indoor Noise Level | <42.5 dB |
| Max. Design Pressure | 4.3/1.5 MPa |
| Operating Temperature | -10 to 58 °C |
| Outdoor Noise Level | <52 dB |
A 48 V battery bank, and nothing else. The supply window is 46 to 58 V DC, so the bank feeds the compressor without an inverter in the path.
12 to 20 m². Below that the 9,000 BTU DGA1-DC48V-09K is the closer match; above 20 m² the 17,300 BTU DGA1-DC48V-18K takes the load.
Input power runs between 200 and 1,200 W in cooling, sitting at 980 W under T1 conditions and 1,090 W under T3. Sizing the bank around those figures is the usual practice.
It carries T1 and T3 climate ratings and an operating range of -10 to 58 °C. At T3 the unit gives 2,910 W, or 9,900 BTU, for 1,090 W of input, an EER of 2.65/9.05.
Refrigerant lines may run 15 m with an 8 m level difference, using 3/8 in gas and 1/4 in liquid pipe. Three metres of pipe and 4 m of connection wire ship with the unit.