Deye 500W Solar Inverter Datasheet — SUN-M50G4-EU-Q0-I
500W microinverter with single MPPT, IP67 protection, and <100ms AC discharge.
SKU: SUN-M50G4-EU-Q0-I | Last Updated: 2026-01-24
⚡Electrical Specifications
| AC Fast Discharge Time | <100 ms |
| AC Output Overcurrent Protection | Yes |
| AC Output Overvoltage Protection | Yes |
| AC Output Short-Circuit Protection | Yes |
| AC Voltage Tolerance (×Un) | 0.85-1.1 |
| Anti-Islanding Protection | Yes |
| DC Injection Current (% of In) | <0.5 |
| DC Reverse Polarity Protection | Yes |
| European Efficiency | 96.0 % |
| Grid Connection Form | L+N+PE |
| Insulation Impedance Detection | Yes |
| Inverter Topology | Isolated |
| Max. AC Output Apparent Power | 500 VA |
| Max. AC Output Current | 2.3/2.2 A |
| Max. Efficiency | 96.5 % |
| Max. Input Short-Circuit Current | 22.5 A |
| Max. Operating PV Input Current | 15 A |
| Max. PV Input Power | 700 W |
| Max. PV Input Voltage | 60 V |
| Number of MPPTs | 1 |
| MPPT Efficiency | >99 % |
| MPPT Voltage Range | 25-55 V |
| Overvoltage Category | OVC II(DC), OVC III(AC) |
| Parallel Units | 10 |
| Power Factor Range (Leading to Lagging) | 0.9-0.9 |
| Supported PV Module Power | 1 x 210-700 W |
| Rated AC Output Active Power | 500 W |
| Rated AC Output Current | 2.3/2.2 A |
| Rated Grid Frequency | 50/45-55, 60/55-65 Hz |
| Rated Output Voltage | 220/230 V |
| Rated PV Input Voltage | 42.5 V |
| Startup Voltage | 20 V |
| Strings per MPPT | 1 |
| Surge Protection Level | TYPE II(AC) |
| Current Total Harmonic Distortion (THDi) | <3 % |
| Warranty (Years) | 10 |
🔧Mechanical Specifications
| Cabinet Dimensions | 173 x 158.5 x 31.5 mm |
| Communication Interfaces | Wi-Fi |
| Weight | 1.85 kg |
🌡️Environmental Specifications
| IP Rating | IP67 |
| Noise Level | <25 dB |
| Operating Temperature Range | -40 to 65 °C |
| Max. Operating Altitude | 2000 m |
| Permissible Ambient Humidity | 0-100 % |
| Thermal Protection | Yes |
| Cooling Type | Natural Cooling |
✅Certifications
IEC 61727IEC 62116CEI 0-21EN 50549NRS 097RD 140UNE 217002OVE-Richtlinie R25G98VDE-AR-N 4105IEC 61000-6-1EN 61000-6-1IEC 61000-6-2EN 61000-6-2IEC 61000-6-3EN 61000-6-3IEC 61000-6-4EN 61000-6-4IEC 62109-1EN 62109-1IEC 62109-2EN 62109-2