Single MPPT
Module-level optimization

500W microinverter with single MPPT, IP67 protection, and <100ms AC discharge.
The Deye SUN-M50G4-EU-Q0-I microinverter series delivers 500W power with module-level optimization. Featuring single MPPT tracker, 96.5% max efficiency, IP67 protection, integrated WiFi, rapid shutdown function, <100ms AC fast discharge for safety compliance, and 25-year design lifetime, it's perfect for balcony PV systems and small residential installations.
| Earth Fault Detection | Yes |
|---|---|
| AC Output Overcurrent Protection | Yes |
| AC Output Overvoltage Protection | Yes |
| AC Output Short Circuit Protection | Yes |
| Communication | Wi-Fi |
| DC Polarity Reverse Connection Protection | Yes |
| DC Terminal Insulation Impedance Monitoring | Yes |
| Equipment Protection | Efficiency |
| Max. AC Output Apparent Power (VA) | 1/1 |
| Max. Input Short Circuit Current (A) | 42.5 |
| No. of MPP Trackers | 25-55 |
| Rated AC Output Active Power (W) | 22.5 |
| PV Modules Supported | 1 × 210-700 W |
| Euro Efficiency | 96.0% |
| Grid Connection Form | L/N/PE |
| Grid Regulation | IEC 61727, IEC 62116, CEI O-21,G98,ENVDE-AR-N50549,NRS4105097, RD 140, UNE 217002, |
| Inverter Topology | Isolated |
| Island Protection Monitoring | Yes |
| MPPT Efficiency | >99% |
| MPPT Voltage Range | 25-55 V |
| Max. AC Output Apparent Power | 500 VA |
| Max. AC Output Current | 2.3/2.2 A |
| Max. Efficiency | 96.5% |
| Max. Input Short Circuit Current | 22.5 A |
| Max. Operating PV Input Current | 15 A |
| Max. PV Input Power | 700 W |
| Max. PV Input Voltage | 60 V |
| Max. Unit per Branch | 10 |
| Over Voltage Category | OVC II(DC), OVC III(AC) |
| Overvoltage Load Drop Protection | Yes |
| Power Factor Adjustment Range | 0.9 leading-0.9 lagging |
| Power Network Monitoring | Yes |
| Rated AC Output Active Power | 500 W |
| Rated AC Output Current | 2.3/2.2 A |
| Rated Output Grid Frequency/Range | 50/45-55,60/55-65 Hz |
| Rated Output Voltage/Range | 220/230 0.85Un-1.1Un V |
| Rated PV Input Voltage | 42.5 V |
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Start-up Voltage | 20 V |
| Thermal Protection | Yes |
| Total Current Harmonic Distortion THDi | <3% |
| Max PV Input | 210-700 W |
| Max PV Voltage | 60 V |
| MPPT Trackers | 1 |
| THDi | <3 % |
| Max Units per Branch | 10 |
| AC Fast Discharge | <100 ms |
| Noise (dB) | 4.8 |
|---|---|
| Type of Cooling | Natural Cooling |
| Ingress Protection(IP) Rating | IP67 |
| IP Rating | IP67 |
| Cooling | Natural Cooling |
| Noise Level | ≤25 dB |
| Noise | ≤25 dB |
|---|---|
| Operating Temperature Range | -40 to +65°C, >45°C Derating °C |
| Permissible Altitude | 2000 m |
| Permissible Ambient Humidity | 0-100% |
| Operating Temperature | -40 to 65 °C |
| Humidity | 0-100 % |
| Max Altitude | 2000 m |




Choosing the best solar inverter in Saudi Arabia in 2026? Compare Deye, Sungrow, Huawei & SMA on heat tolerance, SEC compliance, price & warranty. Free quote on WhatsApp.
Read: Best Solar Inverter for Saudi Homes 2026: Complete Buyer's Guide →Step-by-step hybrid inverter sizing guide for Saudi villas in 2026 — handle multi-AC loads, battery, and generator backup. Free WhatsApp sizing in 15 minutes.
Read: How to Size a Hybrid Solar Inverter for a Saudi Villa (2026 Guide) →Complete 2026 guide to SEC net-metering in Saudi Arabia: SERA rules, application steps, approved inverters, bidirectional meter, and tariffs. Free WhatsApp help.
Read: SEC Net-Metering in Saudi Arabia: How to Apply for Rooftop Solar Approval (2026) →Yes. DEYE inverters are rated for high ambient temperatures and dusty conditions common across the Gulf, North Africa and the wider MEA region, with IP-rated enclosures for outdoor installation in shaded areas.
Each microinverter supports 1 solar panel (up to 700W), with single MPPT tracker for optimization. Multiple units can be connected per branch (17/13/10 units depending on model).
This safety feature ensures AC fast discharge in less than 100ms, complying with the new DIN VDE V 0126-95 standard to protect human safety during maintenance or emergencies.