61.44 kWh from twelve modules
Four to twelve 5.12 kWh, 45 kg modules in series; the full rack holds 61.44 kWh with 55.29 kWh usable at 90% depth of discharge.

Solar BatteriesModel BOS-GL60-GH60
A UL9540-listed high-voltage rack of 5.12 kWh modules delivering 61.44 kWh (55.29 kWh usable) and 60 kW, expandable to 960 kWh across parallel racks.
In stock
Four to twelve 5.12 kWh, 45 kg modules in series; the full rack holds 61.44 kWh with 55.29 kWh usable at 90% depth of discharge.
Listed to UL9540, UL9540A and UL1973 alongside UN38.3, the file inspectors want to see.
Rated DC power of 60 kW with up to 125 A through the BOS-G-PDU-NA distribution unit.
Supports 2P6S and 1P12S pack configurations; GL60 runs 100 A and GH variants run 1P at 50 A.
Up to 16 racks parallel over CAN2.0 and RS485, with as many as 10 AC-coupled inverters cooperating.
LiFePO4 cells retain 70% capacity beyond 6,000 cycles, under a 10-year warranty.
Give a commercial building an afternoon of stored solar from a single footprint of 530 x 2219 x 667 mm. The Deye BOS-GL60 arranges 5.12 kWh, 51.2 V modules of 45 kg each, four to twelve in series, into a rack whose full build reaches 61.44 kWh with 55.29 kWh usable at the recommended 90% depth of discharge, and 60 kW of rated DC power behind it. Two wiring schemes are supported, 2P6S and 1P12S: the GL60 arrangement carries 100 A while GH configurations run 1P at 50 A, and the BOS-G-PDU-NA distribution unit tops out at 125 A. Scaling is generous, with up to 16 racks in parallel toward a 960 kWh ceiling and as many as 10 AC-coupled inverters working together. The certification list, UL9540, UL9540A, UL1973 and UN38.3, answers the questions inspectors ask, LiFePO4 cells run past 6,000 cycles to 70% end-of-life, and the warranty is 10 years. We are an authorised Deye distributor and supply the BOS-GL60-GH60 from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| Energy | 5.12 kWh |
|---|---|
| Usable Energy | 55.29 kWh |
| Module Energy | 5.12 kWh |
| System Energy | 61.44 kWh |
| Max. Capacity | 960 kWh |
| Nominal Voltage | 51.2 V |
| Module Nominal Voltage | 51.2 V |
| System Nominal Voltage | 307.2-614.4 V |
| Operating Voltage | 240-700.8 V |
| Rated Capacity | 100 Ah |
| Module Capacity | 100 Ah |
| Cell Chemistry | LiFePO4 |
| Pack Configuration | 2P6S/1P12S |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70 % |
| Recommended Depth of Discharge | 90 % |
|---|---|
| Rated DC Power | 60 kW |
| Max. Charge Current | 125 A |
| Max. Discharge Current | 125 A |
| Max. Charge/Discharge Current | 125 A |
| Nominal Charge/Discharge Current | 100 A |
| Recommended Charge/Discharge Current | 100/50 A |
| Peak Discharge Current | 125 A |
| Modules in Series | 4-12 |
| Min. Battery Module Quantity | 4 |
| Battery Module Models | BOS-GH20, BOS-GH25, BOS-GH30, BOS-GH35, BOS-GH40, BOS-GH45, BOS-GH50, BOS-GH55, BOS-GH60 |
| Parallel Units | 16 |
| Protection Features | Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing |
| Warranty (Years) | 10 |
| Communication Ports | CAN2.0, RS485 |
|---|---|
| Dimensions | 530 x 2219 x 667 mm |
| Additional Notes | Up to 10 AC inverters parallel (600kW/9600kWh); PDU BOS-G-PDU-NA max 125A; GL60=2P6S/100A, GH=1P/50A |
| Module Dimensions | 440 x 133 x 570 mm |
| Module Weight | 45 kg |
| Status Indicator | Yellow: Battery High Voltage Power On; Red: Battery System Alarm |
| Weight | 635 kg |
| Altitude | <2000 m |
|---|---|
| Charge Temperature | 0-55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-85 % |
| Installation Location | Rack-Mounted |
| Enclosure IP Rating | IP20 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge: 0-55 / Discharge: -20 to 55 °C |
UL9540, UL9540A, UL1973 and UN38.3, a listing set that answers North American style storage-safety requirements at the standards level.
Of the 61.44 kWh in a twelve-module rack, 55.29 kWh is usable at the recommended 90% depth of discharge.
Sixteen racks can run in parallel toward a 960 kWh maximum capacity, and up to 10 inverters can be AC-coupled together.
GL60 uses a 2P6S pack arrangement carrying 100 A, while GH builds run 1P at 50 A; both draw on the same 5.12 kWh module and share the BOS-G-PDU-NA at up to 125 A.
System nominal voltage runs 307.2 to 614.4 V with a 240 to 700.8 V operating window; the IP20 rack weighs 635 kg and belongs indoors below 2,000 m altitude.