87.04 kWh from a short rack
A string of five to seventeen 5.12 kWh modules yields 25.6 to 87.04 kWh inside a 1,629 mm frame.

Solar BatteriesModel BOS-W
A shorter high-voltage rack of 5.12 kWh, 51.2 V modules: five to seventeen in series give 25.6 to 87.04 kWh, with 23.04 to 78.33 kWh usable at 90% discharge.
In stock
A string of five to seventeen 5.12 kWh modules yields 25.6 to 87.04 kWh inside a 1,629 mm frame.
At the recommended 90% depth of discharge, usable energy spans 23.04 to 78.33 kWh.
The bus covers 256 to 870.4 V nominal and operates from 220 to 992.8 V as modules are added.
A built-in air switch handles disconnection, with 100 A continuous flow and a 125 A discharge peak.
CAN2.0 and RS485 ports run both CAN and RS485 protocols, and sixteen racks can parallel.
More than 6,000 cycles to 70% end-of-life capacity, certified to UN38.3.
Fit serious storage into a room where a full-height cabinet will not go. The Deye BOS-W stands 1,629 mm tall, noticeably shorter than its taller stablemates, yet strings five to seventeen 5.12 kWh, 51.2 V modules in series for 25.6 to 87.04 kWh of capacity, 23.04 to 78.33 kWh of it usable at the recommended 90% depth of discharge. The high-voltage bus runs 256 to 870.4 V nominal, operating between 220 and 992.8 V, and current flows at up to 100 A continuous with a 125 A discharge peak; 50 A is the recommended working figure. An air switch acts as the built-in breaker, CAN2.0 and RS485 ports speak both CAN and RS485 protocols to the inverter, and up to sixteen racks can be paralleled. The LiFePO4 cells exceed 6,000 cycles to 70% end-of-life capacity, the pack carries UN38.3 certification, and the stated warranty term is 10 years. Installation is indoors, in the IP20 rack, below 3,000 m. We are an authorised Deye distributor and supply the BOS-W from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| Energy | 5.12 kWh |
|---|---|
| Usable Energy | 23.04-78.33 kWh |
| Module Energy | 5.12 kWh |
| System Energy | 25.6-87.04 kWh |
| Nominal Voltage | 51.2 V |
| Module Nominal Voltage | 51.2 V |
| System Nominal Voltage | 256-870.4 V |
| Operating Voltage | 220-992.8 V |
| Rated Capacity | 100 Ah |
| Module Capacity | 100 Ah |
| Cell Chemistry | LiFePO4 |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70 % |
| Recommended Depth of Discharge | 90 % |
| Rated DC Power | 25.6-87.04 kW |
|---|---|
| Max. Charge Current | 100 A |
| Max. Discharge Current | 100 A |
| Max. Charge/Discharge Current | 100 A |
| Nominal Charge/Discharge Current | 100 A |
| Recommended Charge/Discharge Current | 50 A |
| Peak Discharge Current | 125 A |
| Modules in Series | 5-17 |
| Min. Battery Module Quantity | 5 |
| Battery Module Models | BOS-W25, BOS-W40, BOS-W60, BOS-W85 |
| Parallel Units | 16 |
| Built-in Circuit Breaker | Air Switch |
| Protection Features | Over-Discharge, Over-Charge, Over-Current, Temperature Protection, Cell Balancing |
| Warranty (Years) | 10 |
| Communication Ports | CAN2.0, RS485 |
|---|---|
| Communication Protocol | CAN, RS485 |
| Dimensions | 530 x 1629 x 602 mm |
| Status Indicator | Yellow: Battery High Voltage Power On; Red: Battery System Alarm |
| Weight | 290 kg |
| Altitude | <3000 m |
|---|---|
| Charge Temperature | 0-55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 5-85 % |
| Installation Location | Rack-Mounted |
| Enclosure IP Rating | IP20 |
| Storage Temperature | 0-35 °C |
| Working Temperature | Charge: 0-55 / Discharge: -20 to 55 °C |
The rack measures 530 x 1629 x 602 mm, shorter than a full-height cabinet, weighs 290 kg and installs indoors thanks to its IP20 rating.
From 25.6 kWh with five modules to 87.04 kWh with seventeen, matching the BOS-W25 through BOS-W85 configurations, with 23.04 to 78.33 kWh usable.
The stated warranty term for this model is 10 years, alongside a cycle life above 6,000 cycles to 70% remaining capacity.
Up to 100 A continuous charge and discharge with a 125 A discharge peak; the recommended everyday current is 50 A.
High-voltage battery inverters: the system presents 256 to 870.4 V nominal and operates across 220 to 992.8 V, talking CAN or RS485.