DEYE SUN-7.6K-SG01LP1-US Split Phase Hybrid
DEYE MJS

SUN-7.6K-SG01LP1-US

7.6kW split phase hybrid inverter for US market with 190A charging and 120/240V output.

  • Power Range: 7.6 kW
  • Max Charge Current: 190 A
5,323 AEDincl. VAT
Full Specifications

Features

190A Charging

High-speed battery charging

120/240V Split Phase

US grid compatible

Touch LCD Display

Colorful intuitive interface

16 Units Parallel

Scale up to 121.6kW

AC Coupling

Retrofit existing systems

Generator Support

Store diesel generator energy

Overview

The Deye SUN-7.6K-SG01LP1-US is a split-phase hybrid inverter designed for the US market. With 7.6kW power range, 190A max charging/discharging, 97.6% max efficiency, 40-60V battery support, 120/240V split-phase output, colorful touch LCD, 16 units parallel capability, AC coupling for retrofits, and TYPE3R protection, it's optimized for North American residential energy storage.

Full specifications

Electrical

Max PV Voltage500
Grid Frequency60Hz/55Hz-65Hz
TypeHybrid Inverter
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range40-60 V
Charging Strategy for Li-Ion BatterySelf-adaption to BMS
Communication InterfaceRS232, RS485, CAN
Full Load MPPT Voltage Range200-425 V
Grid Connection Form2L+N+PE
Grid RegulationEN 50549,UNE 217002,NRS 097,IEEE 1547.1,SRD V2.0
Ground Fault Current MonitoringYes
Inverter TopologyNon-Isolated
Island Protection MonitoringYes
MPPT Efficiency>99%
MPPT Voltage Range150-425 V
Max. Efficiency97.60%
Max. Inverter Backfeed Current to The Array0
Max. PV Input Voltage500 V
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)
Number of Battery Input1
Over Voltage CategoryOVC II(DC), OVC IV(AC)
Overvoltage Load Drop ProtectionYes
Power Factor Adjustment Range0.8 leading-0.8 lagging
Power Network MonitoringYes
Rated Input/Output Grid Frequency/Range60Hz/55Hz-65Hz
Rated Input/Output Voltage/Range120/240V; 208V 0.88Un<U<1.1Un V
Rated PV Input Voltage370 V
Residual Current (RCD) DetectionYes
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4,FCC,ULIEC/EN174162109-1, IEC/EN 62109-2,
Start-up Voltage125 V
Surge Protection LevelTYPE II(DC), TYPE II(AC)
Thermal ProtectionYes
Total Current Harmonic Distortion THDi<3% (of nominal power)
Peak Power (off-grid)2 times of rated power, 10s W
Rated AC Power7600 W
Max Charge Current190 A
Max PV Input Power9880 W
MPPT Trackers2
Max Parallel Units16 pcs
Rated Output Voltage120/240V, 208V

Mechanical

Ingress Protection(IP) RatingTYPE3R
Type of CoolingIntelligent Air Cooling
DisplayColorful Touch LCD
IP RatingTYPE3R
CoolingIntelligent Air Cooling
Noise Level<30 dB

Environmental

Noise<30 dB
Operating Temperature Range-40 to +60℃, >45℃ Derating
Permissible Altitude2000m
Permissible Ambient Humidity0-100%
Operating Temperature-40 to 60 Β°C
Max Altitude2,000 m

Certifications

  • EN 50549
  • IEEE 1547.1
  • SRD V2.0
  • UL 1741

Related Products