More energy per cycle
A 90% recommended depth of discharge unlocks 4.61 kWh usable from the 5.12 kWh pack.

The Plus edition of Deye's compact 5.12 kWh pack raises the recommended depth of discharge to 90%, doubles rated throughput to 16 MWh and extends the stated warranty to 10 years.
Authorised Deye distributor for the Middle East — certificate No. GFKFLFI1.
In stock
Or collect it yourself — no carriage
The SE-F5 Plus answers a simple request: keep the compact 5.12 kWh format, but let owners use more of it for longer. Its recommended depth of discharge rises to 90%, unlocking 4.61 kWh of usable energy per cycle, its energy-throughput rating doubles to 16 MWh, and the stated warranty extends to 10 years. The rest of the package stays installer-friendly: 51.2 V nominal, a 370 x 548 x 140 mm housing at 41 kg, natural cooling with no fans to service, and mounting on a wall, on the floor or in a stack. Charging reaches 100 A and discharging 120 A, with a 150 A ten-second peak supporting the 1.5 kW rated DC output. Parallel capability matches its siblings at 32 packs, or 64 over a CAN-Bridge, up to 163.84 kWh. CAN2.0, RS485, Bluetooth and app connectivity are built in, and certification covers UN38.3, CE and CB. We are an authorised Deye distributor and supply the SE-F5-PLUS from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| Energy | 5.12 kWh |
|---|---|
| Usable Energy | 4.61 kWh |
| Max. Capacity | 163.84 kWh |
| Nominal Voltage | 51.2 V |
| Operating Voltage | 44.8-57.6 V |
| Rated Capacity | 100 Ah |
| Cell Chemistry | LiFePO4 |
| Cycle Life | >6000 |
| End-of-Life Capacity | 70 % |
| Energy Throughput | 16 MWh |
| Recommended Depth of Discharge | 90 % |
| Rated DC Power | 1.5 kW |
| Max. Charge Current | 100 A |
| Max. Discharge Current | 120 A |
| Max. Charge/Discharge Current | 100/120 A |
| Recommended Charge/Discharge Current | 30 A |
| Peak Discharge Current | 150 (10s) A |
| Min. Battery Module Quantity | 1 |
| Parallel Units | 32 |
| Warranty (Years) | 10 |
| Communication Ports | CAN2.0, RS485, Bluetooth, APP |
|---|---|
| Dimensions | 370 x 548 x 140 mm |
| Additional Notes | Peak charge current stated (10s); max 64 pcs parallel with CAN-Bridge |
| Status Indicator | LED (SOC, working, protecting), Buzzer |
| Weight | 41 kg |
| Altitude | <3000 m |
|---|---|
| Charge Temperature | 0-55 °C |
| Discharge Temperature | -20 to 55 °C |
| Operating Humidity | 0-95 % |
| Installation Location | Wall-Mounted, Floor-Mounted, Stack-Mounted |
| Enclosure IP Rating | IP21 |
| Storage Temperature | 0-35 °C |
| Cooling Type | Natural Cooling |
| Working Temperature | Charge: -10 to 55 / Discharge: -20 to 55 °C |
Looking up an error code on this Deye SE Spring Series Battery? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →







A 12 V lithium battery, a LiPo pack, an 18650 cell and a car battery are not the same thing. What separates them, and which belongs in a solar system.
Read: Lithium battery types and voltages: 12 V, polymer, 18650 and car batteries →Every capacity the Deye battery records state: 20, 39, 40, 100, 120, 200, 208, 235, 280 and 314 Ah, 1.28 to 4340 kWh — and how your own figure gets built.
Read: Deye Battery Capacities in Saudi Arabia: 20 Ah to 314 Ah →What does Batt-V mean on a Deye inverter? Understand the Deye battery type setting and how to choose between low-voltage (SE-G5.1, SE-F5, RW) and high-voltage (GB-L Pro, BOS-G, BOS-A) batteries for your system.
Read: Deye Battery Type Explained: Batt-V, Low-Voltage vs High-Voltage →Its recommended depth of discharge is 90% instead of 80% - 4.61 kWh usable versus 4.1 kWh - its throughput rating is 16 MWh instead of 8 MWh, and its stated warranty is 10 years rather than 5.
Low-voltage hybrids: the battery runs at 51.2 V nominal across a 44.8-57.6 V window, communicating over CAN2.0 or RS485.
Thirty-two packs operate in parallel - 64 using a CAN-Bridge - for a maximum of 163.84 kWh.
By natural convection: there are no fans in the enclosure, so there is nothing mechanical in the thermal path to maintain.
The IP21 enclosure calls for a protected location below 3,000 m altitude; discharge is rated from -20 to 55 degrees Celsius and storage from 0 to 35 degrees Celsius.