W05Warning

DEYE inverter error W05

Upgrade error warning

Warningthe red LED flashes and the inverter keeps running. Deal with it before it escalates.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-60K-G03SUN-70K-G03SUN-75K-G03+12

What it means

Upgrade error warningThe firmware was upgraded incorrectly.

Cause: The firmware was upgraded incorrectly (a wrong or failed firmware package was loaded).

How to fix it

Upgrade to the correct firmware.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.60 · 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.59 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.59 · +2 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27

What it means

Upgrade error warningFirmware upgrade error warning.

Cause: The firmware was upgraded incorrectly.

How to fix it

Upgrade to the correct firmware.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.56

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

CT Wrong Direction WarningCT_WRONG_direction_warn - a current transformer (CT) is installed in the wrong direction or location.

Cause: The arrow on the CT case does not point toward the inverter, or the CTs are installed in the wrong location.

How to fix it

Check whether the arrow on the CT case points to the inverter, and check that the installation locations of the CTs are correct.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.48 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.49 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.49

Frequently asked questions

What does error W05 mean on a DEYE inverter?
It depends on the model — 4 devices use code W05. On the SUN G01P3-EU-BM8 Series it means: Upgrade error warning. The card for each model on this page gives its exact meaning and fix.
Is error W05 a fault or a warning?
W05 is a warning: the red LED flashes and the unit keeps running. Fix the underlying condition before it escalates.
How do I clear or fix error W05?
Upgrade to the correct firmware. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.