Fed by three to four panels
A series string of 330 W modules at 80-380 V DC drives the unit directly, drawing under 10 A. The 208-240 V single-phase line stays as backup.
Deye Solar Inverters & Lithium Batteries: Prices in Bahrain — Authorized DistributorDeye 12,000 BTU Solar Air Conditioner DGA2-ACDCBLW-12K

A 12,000 BTU PV-direct split sized for rooms of 12 to 20 m², fed by three to four 330 W modules at 80-380 V DC and quiet at under 42.5 dB indoors.
Authorised Deye distributor for Bahrain — certificate No. GFKFLFI1.
Deye solar air conditioner DGA2-ACDCBLW-12K price in Bahrain: BHD 263.
In stock
A reference price in Bahrain: this market is supplied wholesale, at trade prices and quantity terms, delivered within 15 business days.
Become our retailer in your country and get wholesale pricingSize the system for this unitPre-sized systems
Or collect it yourself — no carriage
The DGA2-ACDCBLW-12K is the smallest of the three PV-direct air conditioners in the ACDCBLW line, sized for a bedroom, a home office or a back room of 12 to 20 m². Its DC side takes a string of three to four 330 W modules at 80-380 V and under 10 A, so the compressor works on panel power through the hours the sun is doing the damage. The single-phase 208-240 V, 50/60 Hz connection covers the rest, and an AC power limiter settable from 0 to 600 W decides how much of that supply the unit may take. Rated cooling is 12,000 BTU, or 3,510 W at T1 for 940 W of input, an EER of 3.75/12.75. Under T3 conditions it still returns 9,900 BTU. The same box heats to 14,000 BTU at a COP of 3.50/11.95 and strips 1.3 L/h of moisture from the air, on R410A with an electronic expansion valve and a Highly WHP04200 twin-rotary variable-speed compressor. We are an authorised Deye distributor and supply the DGA2-ACDCBLW-12K from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| AC Power Limiter | 0-600 W |
|---|---|
| Compressor Brand | Highly |
| Compressor Configuration | 2xRotary Inverter |
| Compressor Model | WHP04200 |
| Cooling Capacity | 12000(3000-13300) BTU |
| Cooling Capacity (T1) | 3510(900-3900) W |
| Cooling Capacity (T3) | 9900 BTU |
| Cooling Capacity (T3) | 2910 W |
| Cooling Power Input (T1) | 940(190-1270) W |
| Cooling Power Input (T3) | 1050 W |
| Coefficient of Performance (COP) | 3.50/11.95 |
| DC Input Current | <10 A |
| DC Power Supply | PV In Series |
| DC PV Voltage | 80-380 V |
| Dehumidification | 1.3 L/h |
| EER (T1) | 3.75/12.75 |
| EER (T3) | 2.75/9.45 |
| Electronic Expansion Valve | Yes |
| Heating Capacity | 14000 (3000-15300) BTU |
| Rated Heating Capacity | 4100(1000-4500) W |
| Heating Power Input | 1170(190-1700) W |
| Indoor Airflow | 540/485/435/350 m³/h |
| Indoor Fan Motor | BLDC 15W |
| Outdoor Airflow | 2100 m³/h |
| Outdoor Fan Motor | BLDC 40W |
| Outdoor Fan Speed | 880 rpm |
| Power Supply | 1Ph 208-240V, 50/60Hz |
| Recommended PV Panels | 3-4 |
| Refrigerant | R410A |
| Solar Module Power | 330 W |
| Connection Wire Length | 4 m |
|---|---|
| Container Loading Quantity | 200/85 |
| Dimensions | 802 x 564 x 323 mm |
| Drain Pipe Size | 16 mm |
| Indoor Unit Dimensions | 840 x 205 x 295 mm |
| Indoor Unit Packing Dimensions | 920 x 290 x 360 mm |
| Indoor Unit Weight | 9/12.5 kg |
| Max. Level Difference | 8 m |
| Max. Pipe Length | 15 m |
| Outdoor Unit Packing Dimensions | 910 x 622 x 405 mm |
| Refrigerant Pipe (Gas/Liquid) | 3/8, 1/4 in |
| Supplied Pipe Length | 3 m |
| Weight | 33.5/37.5 kg |
| Climate Type | T3/T1 |
|---|---|
| Indoor Noise Level | <42.5 dB |
| Max. Design Pressure | 4.3/1.5 MPa |
| Operating Temperature | -10 to 58 °C |
| Outdoor Noise Level | <52 dB |






Every capacity the Deye battery records state: 20, 39, 40, 100, 120, 200, 208, 235, 280 and 314 Ah, 1.28 to 4340 kWh — and how your own figure gets built.
Read: Deye Battery Capacities in Saudi Arabia: 20 Ah to 314 Ah →We list 134 solar inverters, each with a published spec record, from 300 W to 136 kW. Five rows separate them: phase, battery, efficiency, derating and noise.
Read: The Deye Inverter Range, Row by Row: What Separates the Models →Programming a Deye is not a list of steps, it is a set of limits the record states. Of 134 inverter records, 52 accept a battery and 49 of those state six programmable charge/discharge periods. Here are the figures.
Read: How to Program a Deye Solar Inverter: Every Setting and the Limit Behind It →Deye gives it an application area of 12 to 20 m², which covers a typical bedroom, a home office or a small shop floor. Beyond 20 m² the 17,300 BTU DGA1-ACDCBLW-18K takes over.
Three to four 330 W modules wired in series. The DC input works over 80-380 V at under 10 A, so the string voltage has to land inside that window.
It also accepts a single-phase 208-240 V, 50/60 Hz supply, so mains covers the hours the panels cannot. How much it may draw from that side is set by the 0-600 W AC power limiter.
It carries a T3 as well as a T1 climate rating and works from -10 to 58 °C. At T3 it returns 2,910 W, or 9,900 BTU, for 1,050 W of input, an EER of 2.75/9.45.
Up to 15 m of refrigerant pipe with a level difference of no more than 8 m. Three metres of pipe and 4 m of connection wire are supplied; the gas and liquid lines are 3/8 in and 1/4 in.