48 V bank, 46-58 V DC
The unit is powered by the battery directly, so it keeps cooling after dark on stored charge instead of waiting for the array.
Deye Solar Inverters & Lithium Batteries: Prices in Sudan — Authorized DistributorDeye 12,000 BTU Solar Air Conditioner DGA1-DC48V-12K

A 12,000 BTU battery-fed split for rooms of 12 to 20 m², wired to a 48 V bank and drawing 980 W at T1 with an EER of 3.60/12.25.
Authorised Deye distributor for Sudan — certificate No. GFKFLFI1.
Deye solar air conditioner DGA1-DC48V-12K price in Sudan: USD 862.
In stock
A reference price in Sudan: this market is supplied wholesale, at trade prices and quantity terms, delivered within 15 business days.
Become our retailer in your country and get wholesale pricingSize the system for this unitPre-sized systems
Or collect it yourself — no carriage
The DGA1-DC48V-12K is the size most off-grid houses need first: 12,000 BTU for a room of 12 to 20 m², wired to nothing but a 48 V battery bank working between 46 and 58 V DC. Because the supply is stored energy, the unit is as useful at two in the morning as at noon, which is the practical difference between this model and a PV-direct machine. It produces 3,510 W of cooling at T1 for 980 W drawn, an EER of 3.60/12.25, and turns down to 200 W when the room is settled. Under T3 conditions output is 9,900 BTU. Heating is rated 13,300 BTU with 1,130 W of input, a COP of 3.45/11.75, and the coil removes 1.3 L/h of moisture. A GMCC ASN98D22UFZ rotary variable-speed compressor works a two-row coil, the outdoor fan moves 2,100 m³/h, and the pair weighs 32 kg net. We are an authorised Deye distributor and supply the DGA1-DC48V-12K from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| Battery Voltage | 48 V |
|---|---|
| Compressor Brand | GMCC |
| Compressor Configuration | Rotary Inverter |
| Compressor Model | ASN98D22UFZ |
| Cooling Capacity | 12000 (3400-12600) BTU |
| Cooling Capacity (T1) | 3510 (1000-3700) W |
| Cooling Capacity (T3) | 9900 BTU |
| Cooling Capacity (T3) | 2910 W |
| Cooling Power Input (T1) | 980 (200-1200) W |
| Cooling Power Input (T3) | 1090 W |
| Coefficient of Performance (COP) | 3.45/11.75 |
| DC Power Supply | 46-58 |
| Dehumidification | 1.3 L/h |
| EER (T1) | 3.60/12.25 |
| EER (T3) | 2.65/9.05 |
| Electronic Expansion Valve | Yes |
| Heating Capacity | 13300 (3400-14000) BTU |
| Rated Heating Capacity | 3900 (1000-4100) W |
| Heating Power Input | 1130 (180-1280) W |
| Indoor Airflow | 540/485/435/350 m³/h |
| Indoor Fan Motor | BLDC 15W |
| Outdoor Airflow | 2100 m³/h |
| Outdoor Coil Rows | 2 |
| Outdoor Coil Tube | 7, Innergroove Tube |
| Outdoor Fan Motor | BLDC 40W |
| Outdoor Fan Speed | 880 rpm |
| Power Supply | Battery |
| Refrigerant | R410A |
| Connection Wire Length | 4 m |
|---|---|
| Container Loading Quantity | 200/85 |
| Dimensions | 802 x 564 x 323 mm |
| Drain Pipe Size | 16 mm |
| Indoor Unit Dimensions | 840 x 205 x 295 mm |
| Indoor Unit Packing Dimensions | 920 x 290 x 360 mm |
| Indoor Unit Weight | 9/12.5 kg |
| Max. Level Difference | 8 m |
| Max. Pipe Length | 15 m |
| Outdoor Unit Packing Dimensions | 910 x 622 x 405 mm |
| Refrigerant Pipe (Gas/Liquid) | 3/8, 1/4 in |
| Supplied Pipe Length | 3 m |
| Weight | 32/36 kg |
| Climate Type | T1/T3 |
|---|---|
| Indoor Noise Level | <42.5 dB |
| Max. Design Pressure | 4.3/1.5 MPa |
| Operating Temperature | -10 to 58 °C |
| Outdoor Noise Level | <52 dB |






Every capacity the Deye battery records state: 20, 39, 40, 100, 120, 200, 208, 235, 280 and 314 Ah, 1.28 to 4340 kWh — and how your own figure gets built.
Read: Deye Battery Capacities in Saudi Arabia: 20 Ah to 314 Ah →We list 134 solar inverters, each with a published spec record, from 300 W to 136 kW. Five rows separate them: phase, battery, efficiency, derating and noise.
Read: The Deye Inverter Range, Row by Row: What Separates the Models →Programming a Deye is not a list of steps, it is a set of limits the record states. Of 134 inverter records, 52 accept a battery and 49 of those state six programmable charge/discharge periods. Here are the figures.
Read: How to Program a Deye Solar Inverter: Every Setting and the Limit Behind It →A 48 V battery bank, and nothing else. The supply window is 46 to 58 V DC, so the bank feeds the compressor without an inverter in the path.
12 to 20 m². Below that the 9,000 BTU DGA1-DC48V-09K is the closer match; above 20 m² the 17,300 BTU DGA1-DC48V-18K takes the load.
Input power runs between 200 and 1,200 W in cooling, sitting at 980 W under T1 conditions and 1,090 W under T3. Sizing the bank around those figures is the usual practice.
It carries T1 and T3 climate ratings and an operating range of -10 to 58 °C. At T3 the unit gives 2,910 W, or 9,900 BTU, for 1,090 W of input, an EER of 2.65/9.05.
Refrigerant lines may run 15 m with an 8 m level difference, using 3/8 in gas and 1/4 in liquid pipe. Three metres of pipe and 4 m of connection wire ship with the unit.