Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-60K-G03SUN-70K-G03SUN-75K-G03+12
What it means
AC Line V,W over voltage — The V-W line voltage is above the protection setting.
Cause: The line voltage between phases V and W exceeds the protection setting; an AC cable that is too thin raises the voltage at the inverter terminals under feed-in.
How to fix it
- Check the AC voltage protection setting, and check if the AC cable is too thin.
- Check the voltage difference between the LCD and a meter.
Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.63 · 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.63 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.62 · +2 more official manuals