Three to six panel string
The 80-380 V DC input takes three to six 330 W modules in series, so the array can be sized to the roof rather than to a fixed count.
Deye Solar Inverters & Lithium Batteries: Prices in Iraq — Authorized DistributorDeye 17,300 BTU Solar Air Conditioner DGA1-ACDCBLW-18K

A 17,300 BTU solar split for living rooms and majlis areas of 20 to 30 m², running on a three to six panel string with 20 m of pipe reach.
Authorised Deye distributor for Iraq — certificate No. GFKFLFI1.
Deye solar air conditioner DGA1-ACDCBLW-18K price in Iraq: USD 700.
In stock
A reference price in Iraq: this market is supplied wholesale, at trade prices and quantity terms, delivered within 15 business days.
Become our retailer in your country and get wholesale pricingSize the system for this unitPre-sized systems
Or collect it yourself — no carriage
Rated at 17,300 BTU, the DGA1-ACDCBLW-18K is the middle unit of the ACDCBLW line and the one most families end up with: it is rated for 20 to 30 m², the size of a living room, a majlis or a two-desk office. Three to six 330 W modules in series supply its 80-380 V DC input, and the 208-240 V single-phase side backs the array up when cloud or evening takes it away. At T1 it delivers 5,070 W for 1,400 W of input, an EER of 3.60/12.35; in T3 heat the output settles at 14,700 BTU. Winter is covered by 20,800 BTU of heating at a COP of 3.45/11.75, and the coil pulls out 1.7 L/h of water. The indoor unit measures 1,080 x 330 x 237 mm, moves up to 980 m³/h on a BLDC 45 W motor and stays under 46 dB. Pipe runs may reach 20 m with a 10 m level difference. We are an authorised Deye distributor and supply the DGA1-ACDCBLW-18K from our own stock, with technical support before and after the sale.
Specifications last updated 24 January 2026
| AC Power Limiter | 0-600 W |
|---|---|
| Compressor Brand | Highly |
| Compressor Configuration | 2xRotary Inverter |
| Compressor Model | WHP05600 |
| Cooling Capacity | 17300(4100-20400) BTU |
| Cooling Capacity (T1) | 5070(1200-6000) W |
| Cooling Capacity (T3) | 14700 BTU |
| Cooling Capacity (T3) | 4290 W |
| Cooling Power Input (T1) | 1400(220-2100) W |
| Cooling Power Input (T3) | 1630 W |
| Coefficient of Performance (COP) | 3.45/11.75 |
| DC Input Current | <10 A |
| DC Power Supply | PV In Series |
| DC PV Voltage | 80-380 V |
| Dehumidification | 1.7 L/h |
| EER (T1) | 3.60/12.35 |
| EER (T3) | 2.65/9.00 |
| Electronic Expansion Valve | Yes |
| Heating Capacity | 20800 (4100-23000) BTU |
| Rated Heating Capacity | 6100(1200-6800) W |
| Heating Power Input | 1770(220-2500) W |
| Indoor Airflow | 980/880/740/620 m³/h |
| Indoor Fan Motor | BLDC 45W |
| Outdoor Airflow | 2200 m³/h |
| Outdoor Fan Motor | BLDC 55W |
| Outdoor Fan Speed | 880 rpm |
| Power Supply | 1Ph 208-240V, 50/60Hz |
| Recommended PV Panels | 3-6 |
| Refrigerant | R410A |
| Solar Module Power | 330 W |
| Connection Wire Length | 5 m |
|---|---|
| Container Loading Quantity | 160/75 |
| Dimensions | 802 x 564 x 323 mm |
| Drain Pipe Size | 16 mm |
| Indoor Unit Dimensions | 1080 x 330 x 237 mm |
| Indoor Unit Packing Dimensions | 1140 x 300 x 382 mm |
| Indoor Unit Weight | 15/18.5 kg |
| Max. Level Difference | 10 m |
| Max. Pipe Length | 20 m |
| Outdoor Unit Packing Dimensions | 910 x 622 x 405 mm |
| Refrigerant Pipe (Gas/Liquid) | 1/2, 1/4 in |
| Supplied Pipe Length | 4 m |
| Weight | 37/42 kg |
| Climate Type | T3/T1 |
|---|---|
| Indoor Noise Level | <46 dB |
| Max. Design Pressure | 4.3/1.5 MPa |
| Operating Temperature | -10 to 58 °C |
| Outdoor Noise Level | <55 dB |






Every capacity the Deye battery records state: 20, 39, 40, 100, 120, 200, 208, 235, 280 and 314 Ah, 1.28 to 4340 kWh — and how your own figure gets built.
Read: Deye Battery Capacities in Saudi Arabia: 20 Ah to 314 Ah →We list 134 solar inverters, each with a published spec record, from 300 W to 136 kW. Five rows separate them: phase, battery, efficiency, derating and noise.
Read: The Deye Inverter Range, Row by Row: What Separates the Models →Programming a Deye is not a list of steps, it is a set of limits the record states. Of 134 inverter records, 52 accept a battery and 49 of those state six programmable charge/discharge periods. Here are the figures.
Read: How to Program a Deye Solar Inverter: Every Setting and the Limit Behind It →It is rated for 20 to 30 m², which is a typical living room or majlis. Smaller rooms are better served by the 12,000 BTU DGA2-ACDCBLW-12K, and above 30 m² by the 22,000 BTU DGA1-ACDCBLW-24K.
Three to six modules of 330 W in series. The string has to sit inside the 80-380 V DC window, and the unit draws under 10 A from it.
In T3 conditions the unit produces 4,290 W, or 14,700 BTU, drawing 1,630 W for an EER of 2.65/9.00. Its working range runs from -10 to 58 °C.
Yes. Rated heating is 6,100 W, modulating between 1,200 and 6,800 W, for 1,770 W of input at a COP of 3.45/11.75.
1.7 L/h of condensate, drained through a 16 mm pipe. An electronic expansion valve meters the R410A charge so the coil keeps dehumidifying at part load.