07Fault

DEYE inverter error 07 (F007)

GFDI blown fuse

Also displayed as F007 / F07 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+3

What it means

GFDI blown fuseThe GFDI protection fuse has blown. The manual notes this code has hardly ever appeared in the field.

Cause: The ground-fault detector/interrupter fuse has blown, which points to a ground-fault current having flowed on the PV side.

How to fix it

Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.61 · 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.50 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.50

Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7

What it means

GFDI blown fuseThe GFDI protection fuse has blown.

Cause: The ground-fault detector/interrupter fuse has blown, which points to a ground-fault current having flowed on the PV side.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or the manufacturer's customer service.

Source: 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.60 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.60 · 060_BManual_SUN-60_70_75K-G01P3-EU-AM8-LV_20260701_en_f559aeec.pdf, p.60 · +1 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27

What it means

GFDI blown fuseThe fuse of the ground-fault detector/interrupter (GFDI) circuit has blown.

Cause: A ground-fault current large enough to blow the GFDI protection fuse has passed, or the fuse circuit itself failed.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or manufacturer customer service.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.56

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+36

What it means

GFDI blown fuseThe fuse of the ground-fault detector/interrupter (GFDI) circuit has blown.

Cause: A ground-fault current large enough to blow the GFDI protection fuse has passed, or the fuse circuit itself failed.

How to fix it

Deye states this code has hardly ever appeared in the field; contact your installer or Deye service if it occurs.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.52 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.56

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

DC/DC Converter 1 Start FailureDCDC1_START_Failure - the BUS voltage cannot be reached by PV or battery.

Cause: DC/DC converter 1 failed to start because the internal BUS voltage could not be built up from the PV or battery input.

How to fix it

Switch off the DC switches and restart the inverter.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.49 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.50 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.50

Also applies to:SUN-5K-SG04LP3-EUSUN-6K-SG04LP3-EUSUN-8K-SG04LP3-EUSUN-10K-SG04LP3-EUSUN-12K-SG04LP3-EUSUN-3K-SG05LP3-EU-SM2SUN-4K-SG05LP3-EU-SM2SUN-5K-SG05LP3-EU-SM2+9

What it means

DC Start FailureDC_START_Failure - the BUS voltage cannot be built from PV or battery.

Cause: The internal BUS voltage could not be built up from the PV or battery input.

How to fix it

  1. Restart the inverter.
  2. If the fault still exists, contact us for help.

Source: 038_BManual_SUN-5_6_8_10_12K-SG04LP3-EU_20260319_en_081932c1.pdf, p.45 · 040_BManual_SUN-3_4_5_6_8_10_12K-SG05LP3-EU-SM2_20260319_en_b0183b7d.pdf, p.45 · 044_BManual_SUN-14_15_16_18_20K-SG05LP3-EU-SM2_20260319_en_ac7cdbd1.pdf, p.45

AI-W5.1 ESS

Energy storage systemFault

Also applies to:AI-W5.1-5P3-EU-B-ESSAI-W5.1-6P3-EU-B-ESSAI-W5.1-8P3-EU-B-ESSAI-W5.1-10P3-EU-B-ESSAI-W5.1-12P3-EU-B-ESSGB-SL5K-EUGB-SL6K-EUGB-SL8K-EU+11

What it means

DC_START_FailureDC start failure - the internal BUS voltage cannot be built up.

Cause: Neither PV nor battery could establish the internal BUS voltage at start-up - insufficient input voltage or a start-up circuit fault.

How to fix it

  1. Restart the inverter.
  2. If the fault still exists, contact Deye for help.

Source: 002_Download_4e90fe7a.pdf, p.46 · 081_deye_gb_sl_pro_user_manual_46fa941a.pdf, p.49 · 010_Download_cc05df18.pdf, p.44

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Cell over temperatureCell temperature rose above the protection limit; charge/discharge is stopped until the pack cools.

Cause: Sustained high charge/discharge current, high ambient temperature, or poor ventilation around the battery drove the cell temperature above its limit.

How to fix it

  1. Stop charging/discharging and let the battery cool.
  2. Improve ventilation and keep the battery within its rated operating temperature range.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_OVER_DIFF_VOLT_LEV_2Excessive voltage differences between cells/modules (manual wording: 'excessive pressure differences').

Cause: The voltage gap between the highest and lowest cell or module exceeded the level-2 threshold - cell imbalance from aging, long storage, or a weak module.

How to fix it

  1. Charge the bank fully at low current so the BMS can balance the cells.
  2. If the difference does not close after several full charges, contact Deye support.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.12

Frequently asked questions

What does error 07 mean on a DEYE inverter?
It depends on the model — 13 devices use code 07. On the SUN G01P3-EU-BM8 Series it means: GFDI blown fuse. The card for each model on this page gives its exact meaning and fix.
Is error 07 a fault or a warning?
07 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 07?
Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.