19Fault

DEYE inverter error 19 (F019)

All hardware failure synthesis

Also displayed as F019 / F19 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8

What it means

All hardware failure synthesisAggregate flag raised when hardware protection faults occur in combination. The manual notes this code has hardly ever appeared in the field.

Cause: Several hardware protection signals tripped together; the inverter raises this synthesized (aggregate) hardware-failure flag.

How to fix it

Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.61

SUN G02P1-EU Series

InverterFault

Also applies to:SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2SUN-9K-G02P1-EU-AM2SUN-10K-G02P1-EU-AM2SUN-10.5K-G02P1-EU-AM2

What it means

All hardware failure synthesisAggregate flag for combined hardware protection faults; on these models it can be triggered by hot-plugging the WiFi logger.

Cause: Plugging the WiFi logger in while the inverter is running raises F19; otherwise it is the aggregate flag for combined hardware protection trips.

How to fix it

Restart the inverter or perform a factory reset; if the error still exists, contact your installer or Deye service.

Source: 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.51 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.51

Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7

What it means

All hardware failure synthesisAggregate flag raised when hardware protection faults occur in combination.

Cause: Several hardware protection signals tripped together; the inverter raises this synthesized (aggregate) hardware-failure flag.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or the manufacturer's customer service.

Source: 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.60 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.60 · 060_BManual_SUN-60_70_75K-G01P3-EU-AM8-LV_20260701_en_f559aeec.pdf, p.60 · +1 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27

What it means

All hardware failure synthesisCombined (synthesized) hardware failure signal; several hardware protections asserted together.

Cause: Multiple hardware fault signals were present at the same time.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or manufacturer customer service.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.57

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+15

What it means

All hardware failure synthesisCombined (synthesized) hardware failure signal; several hardware protections asserted together.

Cause: Plugging the WiFi logger in while the inverter is running can trigger F19; otherwise several hardware fault signals were present at once.

How to fix it

Restart the inverter or perform a factory reset; if the error still exists, contact your installer or Deye service.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.53

SUN G06P3-EU Series

InverterFault

Also applies to:SUN-3K-G06P3-EU-AM2-P1SUN-4K-G06P3-EU-AM2-P1SUN-5K-G06P3-EU-AM2-P1SUN-6K-G06P3-EU-AM2-P1SUN-7K-G06P3-EU-AM2-P1SUN-8K-G06P3-EU-AM2-P1SUN-9K-G06P3-EU-AM2-P1SUN-10K-G06P3-EU-AM2-P1+13

What it means

All hardware failure synthesisCombined (synthesized) hardware failure signal; several hardware protections asserted together.

Cause: Multiple hardware fault signals were present at the same time.

How to fix it

Deye states this code has hardly ever appeared in the field; contact your installer or Deye service if it occurs.

Source: 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.56

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

Integrated Transient FaultTz_Integ_Fault - integrated transient hardware protection fault.

Cause: An internal combined (integrated) transient hardware protection was triggered.

How to fix it

Restart the inverter 3 times and restore the factory settings.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.49 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.50 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.50

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

AFE-OCDL/OCD1/OCD2Hardware over-current discharge protection (OCD level 1/2/latch) from the BMS analog front end tripped.

Cause: The analog front-end chip detected discharge current above its hardware protection levels - a heavy surge or a short circuit on the battery terminals.

How to fix it

  1. Disconnect the load, inspect the DC cabling for shorts, and restart the battery.
  2. If the protection trips again immediately, contact Deye support.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_SOC_LOW_LEV_2The SOC is too low.

Cause: State of charge fell below the allowed lower limit - the battery was discharged without timely recharging.

How to fix it

Recharge the battery promptly from PV or grid; check the PCS discharge cut-off settings so the bank is not run this low again.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.13

Frequently asked questions

What does error 19 mean on a DEYE inverter?
It depends on the model — 10 devices use code 19. On the SUN G01P3-EU-BM8 Series it means: All hardware failure synthesis. The card for each model on this page gives its exact meaning and fix.
Is error 19 a fault or a warning?
19 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 19?
Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.