46Fault

DEYE inverter error 46 (F046)

AC Line U,V low voltage

Also displayed as F046 / F46 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-60K-G03SUN-70K-G03SUN-75K-G03+12

What it means

AC Line U,V low voltageThe U-V line voltage is below the protection setting.

Cause: The line voltage between phases U and V is below the protection setting.

How to fix it

Check the AC voltage protection setting.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.63 · 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.63 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.62 · +2 more official manuals

SUN G02P1-EU Series

InverterFault

Also applies to:SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2SUN-9K-G02P1-EU-AM2SUN-10K-G02P1-EU-AM2SUN-10.5K-G02P1-EU-AM2

What it means

AC Line U,V low voltageThe U-V line voltage is below the protection setting. Marked 'Not available' in the manual for these models.

Cause: Line voltage protection between phases U and V - a three-phase measurement that is not used on these single-phase models.

How to fix it

  1. Marked 'Not available' in the manual - this code is not used on these models.
  2. If it is displayed nonetheless, restart the inverter and contact your installer or Deye service.

Source: 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.52 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.52

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+48

What it means

AC Line U,V low voltageThe line voltage between phases U and V is below the protection setting.

Cause: Grid U-V line voltage below the protection setting.

How to fix it

Check the AC voltage protection setting.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.58 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.58

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+15

What it means

AC Line U,V low voltageLine low-voltage protection for the U-V pair (marked 'Not available' on single-phase models).

Cause: Line-voltage protection for the U-V phase pair; single-phase units have no such line pair, so the code is not used.

How to fix it

Marked 'Not available' on these single-phase models - the code is not used.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.54

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

Grid UndervoltageAC_UV_UnderVolt_Fault - grid voltage out of range (too low).

Cause: The grid voltage is below the range given in the specification.

How to fix it

  1. Check that the voltage is in the range of the specification
  2. Check whether the AC cables are firmly and correctly connected.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.51 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.52 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.52

Also applies to:SUN-5K-SG04LP3-EUSUN-6K-SG04LP3-EUSUN-8K-SG04LP3-EUSUN-10K-SG04LP3-EUSUN-12K-SG04LP3-EUSUN-3K-SG05LP3-EU-SM2SUN-4K-SG05LP3-EU-SM2SUN-5K-SG05LP3-EU-SM2+9

What it means

Backup Battery FaultBackup battery fault - the battery status is abnormal or inconsistent.

Cause: The status of the batteries is inconsistent - voltage, SOC or other parameters differ between the batteries.

How to fix it

  1. Check each battery's status, such as voltage/SOC and other parameters, and make sure all the parameters are the same
  2. If the fault still exists, contact us for help.

Source: 038_BManual_SUN-5_6_8_10_12K-SG04LP3-EU_20260319_en_081932c1.pdf, p.47 · 040_BManual_SUN-3_4_5_6_8_10_12K-SG05LP3-EU-SM2_20260319_en_b0183b7d.pdf, p.47 · 044_BManual_SUN-14_15_16_18_20K-SG05LP3-EU-SM2_20260319_en_ac7cdbd1.pdf, p.47

AI-W5.1 ESS

Energy storage systemFault

Also applies to:AI-W5.1-5P3-EU-B-ESSAI-W5.1-6P3-EU-B-ESSAI-W5.1-8P3-EU-B-ESSAI-W5.1-10P3-EU-B-ESSAI-W5.1-12P3-EU-B-ESS

What it means

Backup battery faultBackup battery fault - paralleled batteries are inconsistent.

Cause: One of the connected batteries has voltage, SOC, or parameter settings that do not match the others.

How to fix it

  1. Check each battery's status (voltage, SOC, and parameters) and make sure all parameters are the same.
  2. If the fault still exists, contact Deye for help.

Source: 002_Download_4e90fe7a.pdf, p.48

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Mos Adhesion SuspThe BMS suspects a main MOSFET is stuck conducting.

Cause: The self-test result suggests MOSFET contact adhesion - the switch may no longer open the circuit reliably.

How to fix it

  1. Power-cycle the battery to re-run the self-test.
  2. If the code returns, take the battery out of service and contact Deye support.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_PRECHAGE_ERRORThe precharge failed.

Cause: The precharge circuit could not raise the bus voltage - a short or very large capacitive load on the DC bus, or a failed precharge resistor.

How to fix it

  1. Disconnect and check the DC bus and PCS side for shorts, then restart.
  2. If precharge still fails, contact Deye support.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.14

Frequently asked questions

What does error 46 mean on a DEYE inverter?
It depends on the model — 12 devices use code 46. On the SUN G01P3-EU-BM8 Series it means: AC Line U,V low voltage. The card for each model on this page gives its exact meaning and fix.
Is error 46 a fault or a warning?
46 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 46?
Check the AC voltage protection setting. The exact steps for each affected model are listed on this page.