54Fault

DEYE inverter error 54 (F054)

AC inductor C, phase current DC current high

Also displayed as F054 / F54 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

Severity differs by model — check your model below.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+3

What it means

AC inductor C, phase current DC current highThe DC current through AC filter inductor phase C is too high. The manual notes this code has hardly ever appeared in the field.

Cause: The DC current component through AC filter inductor phase C exceeds the allowed limit.

How to fix it

Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.63 · 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.53 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.53

Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7

What it means

AC inductor C, phase current DC current highThe DC current through AC filter inductor phase C is too high.

Cause: The DC current component through AC filter inductor phase C exceeds the allowed limit.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or the manufacturer's customer service.

Source: 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.63 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.62 · 060_BManual_SUN-60_70_75K-G01P3-EU-AM8-LV_20260701_en_f559aeec.pdf, p.62 · +1 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27

What it means

AC inductor C, phase current DC current highThe DC current through AC filter inductor phase C is too high.

Cause: The DC component of the current in AC inductor phase C exceeded its limit.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or manufacturer customer service.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.59

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+36

What it means

AC inductor C, phase current DC current highThe DC current through AC filter inductor phase C is too high.

Cause: The DC component of the current in AC inductor phase C exceeded its limit.

How to fix it

Deye states this code has hardly ever appeared in the field; contact your installer or Deye service if it occurs.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.55 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.58

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

Battery 2 Voltage HighBAT2_VoltHigh_Fault - the terminal voltage of battery input 2 is too high.

Cause: The voltage measured at the battery 2 terminals is above the limit.

How to fix it

  1. Check whether the battery 2 terminal voltage is high
  2. Restart the inverter 2 times and restore the factory settings.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.52 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.53 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.53

GB-SL / GB-SL Pro ESS

Energy storage systemFault

Also applies to:GB-SL5K-EUGB-SL6K-EUGB-SL8K-EUGB-SL10K-EUGB-SL12K-EUGB-SL15K-EUGB-SL20K-EUGB-SL Pro 5K-EU+6

What it means

BAT2_VoltHigh_FaultBattery 2 terminal voltage is too high.

Cause: The voltage measured at the battery 2 terminals exceeded the limit - battery over-voltage or wrong battery settings.

How to fix it

  1. Check the battery 2 terminal voltage, restart the inverter twice and restore the factory settings.
  2. Seek help from Deye if it does not recover.

Source: 081_deye_gb_sl_pro_user_manual_46fa941a.pdf, p.51 · 010_Download_cc05df18.pdf, p.46

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

VOLT_OPEN_WIRE_FAILAn open wire was detected in the cell-voltage sampling harness.

Cause: A cell-voltage sampling lead is broken or disconnected, so the BMS reads an open circuit on that channel.

How to fix it

  1. Restart the battery.
  2. If the code persists, the sampling harness needs internal service - contact Deye support.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryWarning

Also applies to:GB-A

What it means

ALARM_ID_TCP_CONNECT_FAILTCP connection failure.

Cause: The battery's network (TCP) connection to the monitoring platform could not be established - LAN cabling, router, or network configuration issue. Battery operation itself does not depend on this link.

How to fix it

  1. Check the network cable, router, and network settings for the battery's monitoring connection, then restart.
  2. Contact Deye support if it will not connect.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.14

Frequently asked questions

What does error 54 mean on a DEYE inverter?
It depends on the model — 11 devices use code 54. On the SUN G01P3-EU-BM8 Series it means: AC inductor C, phase current DC current high. The card for each model on this page gives its exact meaning and fix.
Is error 54 a fault or a warning?
It depends on the model: on some models 54 is a fault (output cut, red LED solid), on others a warning (red LED flashing, unit keeps running). Check the card for your model on this page.
How do I clear or fix error 54?
Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.