Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+3
What it means
AC inductor C, phase current DC current high — The DC current through AC filter inductor phase C is too high. The manual notes this code has hardly ever appeared in the field.
Cause: The DC current component through AC filter inductor phase C exceeds the allowed limit.
How to fix it
Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code.
Source: sun-120k-g01p3-eu-bm8-sun-125k-g01p3-eu-bm8-sun-130k-g01p3-eu-bm8-manual.pdf, p.63 · sun-7k-g02p1-eu-am2-sun-7-5k-g02p1-eu-am2-sun-8k-g02p1-eu-am2-manual.pdf, p.53 · sun-9k-g02p1-eu-am2-sun-10k-g02p1-eu-am2-sun-10-5k-g02p1-eu-am2-manual.pdf, p.53
Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7
What it means
AC inductor C, phase current DC current high — The DC current through AC filter inductor phase C is too high.
Cause: The DC current component through AC filter inductor phase C exceeds the allowed limit.
How to fix it
Restart the inverter; if the fault is not ruled out, contact the installer or the manufacturer's customer service.
Source: sun-70k-g03-sun-75k-g03-sun-80k-g03-sun-90k-g03-sun-100k-g03-sun-110k-g03-manual.pdf, p.63 · sun-120k-g01p3-eu-am8-manual.pdf, p.62 · sun-60k-g01p3-eu-am8-lv-sun-70k-g01p3-eu-am8-lv-sun-75k-g01p3-eu-am8-lv-manual.pdf, p.62 · +1 more official manuals
Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27
What it means
AC inductor C, phase current DC current high — The DC current through AC filter inductor phase C is too high.
Cause: The DC component of the current in AC inductor phase C exceeded its limit.
How to fix it
Restart the inverter; if the fault is not ruled out, contact the installer or manufacturer customer service.
Source: sun-6k-g06-lv-p1-manual.pdf, p.59
Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+36
What it means
AC inductor C, phase current DC current high — The DC current through AC filter inductor phase C is too high.
Cause: The DC component of the current in AC inductor phase C exceeded its limit.
How to fix it
Deye states this code has hardly ever appeared in the field; contact your installer or Deye service if it occurs.
Source: sun-2-7k-g04p1-eu-am1-sun-3k-g04p1-eu-am1-sun-3-3k-g04p1-eu-am1-sun-3-6k-g04p1-eu-am1-sun-4k-g04p1-eu-am1-manual.pdf, p.55 · sun-7k-g06p3-eu-bm2-sun-8k-g06p3-eu-bm2-sun-9k-g06p3-eubm2-sun-10k-g06p3-eu-bm2-sun-12k-g06p3-eu-bm2-manual.pdf, p.58
Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9
What it means
Battery 2 Voltage High — BAT2_VoltHigh_Fault - the terminal voltage of battery input 2 is too high.
Cause: The voltage measured at the battery 2 terminals is above the limit.
How to fix it
- 1Check whether the battery 2 terminal voltage is high
- 2Restart the inverter 2 times and restore the factory settings.
Source: sun-12k-sg01hp3-eu-am2-manual.pdf, p.52 · sun-29.9-30-35-40-50k-sg01hp3-eu-bm3-4-20260224-en-manual.pdf, p.53 · sun-60-70-75-80k-sg02hp3-eu-em6-20260224-en-manual.pdf, p.53
Energy storage systemFault Also applies to:GB-SL5K-EUGB-SL6K-EUGB-SL8K-EUGB-SL10K-EUGB-SL12K-EUGB-SL15K-EUGB-SL20K-EUGB-SL Pro 5K-EU+6
What it means
BAT2_VoltHigh_Fault — Battery 2 terminal voltage is too high.
Cause: The voltage measured at the battery 2 terminals exceeded the limit - battery over-voltage or wrong battery settings.
How to fix it
- 1Check the battery 2 terminal voltage, restart the inverter twice and restore the factory settings.
- 2Seek help from Deye if it does not recover.
Source: gb-s12k-eu-gb-s15k-eugb-s20k-eu-gb-s15k-eu-gb-s20k-eu-manual.pdf, p.51 · gb-s5k-eu-gb-s20k-eu-datasheet.pdf, p.46
Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7
What it means
VOLT_OPEN_WIRE_FAIL — An open wire was detected in the cell-voltage sampling harness.
Cause: A cell-voltage sampling lead is broken or disconnected, so the BMS reads an open circuit on that channel.
How to fix it
- 1Restart the battery.
- 2If the code persists, the sampling harness needs internal service - contact Deye support.
Source: deye-rw-l2.5a-user-manual-en.pdf, p.10 · rw-f16-manual.pdf, p.10 · rw-l10-2-manual.pdf, p.10 · +6 more official manuals
Also applies to:GB-A
What it means
ALARM_ID_TCP_CONNECT_FAIL — TCP connection failure.
Cause: The battery's network (TCP) connection to the monitoring platform could not be established - LAN cabling, router, or network configuration issue. Battery operation itself does not depend on this link.
How to fix it
- 1Check the network cable, router, and network settings for the battery's monitoring connection, then restart.
- 2Contact Deye support if it will not connect.
Source: gb-a-pack6-gb-a4-gb-a10-gb-a16-manual.pdf, p.14