What it means
DC busbar voltage is too high — The DC bus voltage is above the limit.
Cause: The DC bus (Ubus) voltage is above the limit - usually the PV input voltage is too high because too many solar panels are connected in series, or the Ubus detection circuit is faulty.
How to fix it
- 1Check the PV voltage and the Ubus voltage and their detection circuit; if the PV input voltage exceeds the limit, reduce the number of solar panels in series
- 2For the Ubus voltage, check the LCD display.
Source: sun-120k-g01p3-eu-bm8-sun-125k-g01p3-eu-bm8-sun-130k-g01p3-eu-bm8-manual.pdf, p.63 · sun-7k-g02p1-eu-am2-sun-7-5k-g02p1-eu-am2-sun-8k-g02p1-eu-am2-manual.pdf, p.53 · sun-9k-g02p1-eu-am2-sun-10k-g02p1-eu-am2-sun-10-5k-g02p1-eu-am2-manual.pdf, p.53 · +4 more official manuals
Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+71
What it means
DC busbar voltage is too high — The DC bus voltage exceeded its upper limit.
Cause: PV input voltage above the permitted limit (too many solar panels in series), or a problem in the Ubus voltage detection circuit.
How to fix it
Check the PV voltage, the Ubus voltage, and its detection circuit; if the PV input voltage exceeds the limit, reduce the number of solar panels in series; check the Ubus voltage on the LCD display.
Source: sun-6k-g06-lv-p1-manual.pdf, p.59 · sun-2-7k-g04p1-eu-am1-sun-3k-g04p1-eu-am1-sun-3-3k-g04p1-eu-am1-sun-3-6k-g04p1-eu-am1-sun-4k-g04p1-eu-am1-manual.pdf, p.55 · sun-7k-g06p3-eu-bm2-sun-8k-g06p3-eu-bm2-sun-9k-g06p3-eubm2-sun-10k-g06p3-eu-bm2-sun-12k-g06p3-eu-bm2-manual.pdf, p.58
Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9
What it means
Battery 1 Voltage High — BAT1_VoltHigh_Fault - the terminal voltage of battery input 1 is too high.
Cause: The voltage measured at the battery 1 terminals is above the limit.
How to fix it
- 1Check whether the battery 1 terminal voltage is high
- 2Restart the inverter 2 times and restore the factory settings.
Source: sun-12k-sg01hp3-eu-am2-manual.pdf, p.52 · sun-29.9-30-35-40-50k-sg01hp3-eu-bm3-4-20260224-en-manual.pdf, p.53 · sun-60-70-75-80k-sg02hp3-eu-em6-20260224-en-manual.pdf, p.53
Also applies to:SUN-5K-SG04LP3-EUSUN-6K-SG04LP3-EUSUN-8K-SG04LP3-EUSUN-10K-SG04LP3-EUSUN-12K-SG04LP3-EUSUN-3K-SG05LP3-EU-SM2SUN-4K-SG05LP3-EU-SM2SUN-5K-SG05LP3-EU-SM2+9
What it means
DC Busbar Voltage Too High — DC busbar voltage is too high - the internal BUS voltage is too high.
Cause: The DC busbar (BUS) voltage is too high because the battery voltage is too high or the PV input voltage is outside the allowed range.
How to fix it
- 1Check whether the battery voltage is too high
- 2Check the PV input voltage and make sure it is within the allowed range
- 3Seek help from us if it cannot go back to the normal state.
Source: sun-5-6-8-10-12k-sg04lp3-eu-20260319-en-manual.pdf, p.47 · sun-3-4-5-6-8-10-12k-sg05lp3-eu-sm2-20260319-en-manual.pdf, p.47 · sun-14-15-16-18-20k-sg05lp3-eu-sm2-20260319-en-manual.pdf, p.47
Energy storage systemFault Also applies to:AI-W5.1-5P3-EU-B-ESSAI-W5.1-6P3-EU-B-ESSAI-W5.1-8P3-EU-B-ESSAI-W5.1-10P3-EU-B-ESSAI-W5.1-12P3-EU-B-ESS
What it means
DC busbar voltage is too high — BUS voltage is too high.
Cause: The internal BUS voltage exceeded its limit - battery voltage too high or PV input voltage above the allowed range.
How to fix it
- 1Check whether the battery voltage is too high and that the PV input voltage is within the allowed range.
- 2Seek help from Deye if it does not recover.
Source: ai-w5-1-b-datasheet.pdf, p.48
Energy storage systemFault Also applies to:GB-SL5K-EUGB-SL6K-EUGB-SL8K-EUGB-SL10K-EUGB-SL12K-EUGB-SL15K-EUGB-SL20K-EUGB-SL Pro 5K-EU+6
What it means
BAT1_VoltHigh_Fault — Battery 1 terminal voltage is too high.
Cause: The voltage measured at the battery 1 terminals exceeded the limit - battery over-voltage or wrong battery settings.
How to fix it
- 1Check the battery 1 terminal voltage, restart the inverter twice and restore the factory settings.
- 2Seek help from Deye if it does not recover.
Source: gb-s12k-eu-gb-s15k-eugb-s20k-eu-gb-s15k-eu-gb-s20k-eu-manual.pdf, p.51 · gb-s5k-eu-gb-s20k-eu-datasheet.pdf, p.46
Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7
What it means
TEMP_OPEN_WIRE_FAIL — An open wire was detected in the temperature-sensor harness.
Cause: A temperature-sensor lead is broken or disconnected, so the BMS reads an open circuit on that channel.
How to fix it
- 1Restart the battery.
- 2If the code persists, contact Deye support.
Source: deye-rw-l2.5a-user-manual-en.pdf, p.10 · rw-f16-manual.pdf, p.10 · rw-l10-2-manual.pdf, p.10 · +6 more official manuals
Also applies to:GB-A
What it means
ALARM_ID_W5500_SPI_COMM_FAIL — The W5500 (Ethernet controller) SPI communication fails.
Cause: The BMS lost internal SPI communication with its W5500 Ethernet controller chip - a fault on the network interface, affecting monitoring connectivity.
How to fix it
- 1Restart the system.
- 2If the fault persists, contact Deye support for service of the communication board.
Source: gb-a-pack6-gb-a4-gb-a10-gb-a16-manual.pdf, p.14