What it means
AC over current fault of hardware — Hardware-level AC over-current protection tripped.
Cause: The AC output current exceeded the hardware protection limit; the AC sensor or its detection circuit on the control board, or the connection wiring, may be faulty.
How to fix it
- 1Check the AC sensor and its detection circuit on the control board and the connection wiring
- 2Restart the inverter or perform a factory reset; if the error still exists, contact your installer or Deye service.
Source: sun-120k-g01p3-eu-bm8-sun-125k-g01p3-eu-bm8-sun-130k-g01p3-eu-bm8-manual.pdf, p.61 · sun-7k-g02p1-eu-am2-sun-7-5k-g02p1-eu-am2-sun-8k-g02p1-eu-am2-manual.pdf, p.51 · sun-9k-g02p1-eu-am2-sun-10k-g02p1-eu-am2-sun-10-5k-g02p1-eu-am2-manual.pdf, p.51
Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7
What it means
AC over current fault of hardware — Hardware-level AC over-current protection tripped.
Cause: The AC output current exceeded the hardware protection limit; the AC sensor or its detection circuit on the control board, or the connection wiring, may be faulty.
How to fix it
- 1Check the AC sensor and its detection circuit on the control board and the connection wiring
- 2Restart the inverter or perform a factory reset; if the error still exists, contact your installer.
Source: sun-70k-g03-sun-75k-g03-sun-80k-g03-sun-90k-g03-sun-100k-g03-sun-110k-g03-manual.pdf, p.60 · sun-120k-g01p3-eu-am8-manual.pdf, p.60 · sun-60k-g01p3-eu-am8-lv-sun-70k-g01p3-eu-am8-lv-sun-75k-g01p3-eu-am8-lv-manual.pdf, p.60 · +1 more official manuals
Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+71
What it means
AC over current fault of hardware — The hardware over-current protection on the AC side tripped.
Cause: The AC sensor or detection circuit on the control board or its connection wire is faulty, or a real AC over-current occurred.
How to fix it
- 1Check the AC sensor and detection circuit on the control board and its wiring.
- 2Restart the inverter or perform a factory reset; if the error still exists, contact your installer or Deye service.
Source: sun-6k-g06-lv-p1-manual.pdf, p.57 · sun-2-7k-g04p1-eu-am1-sun-3k-g04p1-eu-am1-sun-3-3k-g04p1-eu-am1-sun-3-6k-g04p1-eu-am1-sun-4k-g04p1-eu-am1-manual.pdf, p.53 · sun-7k-g06p3-eu-bm2-sun-8k-g06p3-eu-bm2-sun-9k-g06p3-eubm2-sun-10k-g06p3-eu-bm2-sun-12k-g06p3-eu-bm2-manual.pdf, p.56
Also applies to:SUN-3.6K-SG05LP1-EU-SM2-PSUN-5K-SG05LP1-EU-SM2-PSUN-6K-SG05LP1-EU-SM2-PSUN-7K-SG05LP1-EU-SM2-PSUN-7.6K-SG05LP1-EU-SM2-PSUN-8K-SG05LP1-EU-SM2-PSUN-10K-SG05LP1-EU-SM2-PSUN-7.6K-SG01LP1-EU+21
What it means
AC over current fault of hardware — AC side over current fault detected by the hardware.
Cause: The backup load power or common load power is outside the allowed range, tripping the AC side hardware overcurrent protection.
How to fix it
- 1Check whether the backup load power and common load power are within the range, then restart and check whether operation is normal.
- 2Seek help from Deye if the inverter cannot go back to the normal state.
Source: sun-3.6-5-6-7-7.6-8-10k-sg05lp1-eu-sm2-p-20260428-en-manual.pdf, p.49 · sun-12-14-16k-sg01lp1-eu-20260519-en-manual.pdf, p.45 · sun-3.6-6-k-og01lp1-eu-am2-20260406-en-manual.pdf, p.45 · +4 more official manuals
Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9
What it means
AC Transient Overcurrent (Hardware) — Tz_AC_OverCurr_Fault - AC side overcurrent fault detected by hardware.
Cause: The AC-side current exceeded the hardware protection limit, typically because the backup load power and common load power are beyond the allowed range.
How to fix it
- 1Check whether the backup load power and common load power are within the range
- 2Restart and check whether it is normal.
Source: sun-12k-sg01hp3-eu-am2-manual.pdf, p.49 · sun-29.9-30-35-40-50k-sg01hp3-eu-bm3-4-20260224-en-manual.pdf, p.50 · sun-60-70-75-80k-sg02hp3-eu-em6-20260224-en-manual.pdf, p.50
Also applies to:SUN-5K-SG02LP2-US-AM2SUN-6K-SG02LP2-US-AM2SUN-7.6K-SG02LP2-US-AM2SUN-8K-SG02LP2-US-AM2SUN-10K-SG02LP2-US-AM3SUN-12K-SG02LP2-US-AM3SUN-5K-SG04LP3-EUSUN-6K-SG04LP3-EU+15
What it means
AC Overcurrent (Hardware) — AC over current fault of hardware - AC side overcurrent fault detected by hardware.
Cause: The AC-side current exceeded the hardware protection limit, typically because the backup load power and common load power are beyond the allowed range.
How to fix it
- 1Check whether the backup load power and common load power are within the range
- 2Restart and check whether it is normal
- 3Seek help from us if it cannot go back to the normal state.
Source: sun-5k-sg02lp2-us-am2-sun-10k-sg02lp2-us-am3-sun-12k-sg02lp2-us-am3-manual.pdf, p.54 · sun-5-6-8-10-12k-sg04lp3-eu-20260319-en-manual.pdf, p.46 · sun-3-4-5-6-8-10-12k-sg05lp3-eu-sm2-20260319-en-manual.pdf, p.46 · +1 more official manuals
Energy storage systemFault Also applies to:AI-W5.1-5P3-EU-B-ESSAI-W5.1-6P3-EU-B-ESSAI-W5.1-8P3-EU-B-ESSAI-W5.1-10P3-EU-B-ESSAI-W5.1-12P3-EU-B-ESS
What it means
AC over current fault of hardware — AC side over-current fault (hardware detection).
Cause: The combined backup-load and common-load power exceeded the inverter's AC output range, tripping the hardware over-current protection.
How to fix it
- 1Check that the backup load power and common load power are within range, restart, and check whether operation is normal.
- 2Seek help from Deye if it does not recover.
Source: ai-w5-1-b-datasheet.pdf, p.46
Energy storage systemFault Also applies to:GB-SL5K-EUGB-SL6K-EUGB-SL8K-EUGB-SL10K-EUGB-SL12K-EUGB-SL15K-EUGB-SL20K-EUGB-SL Pro 5K-EU+6
What it means
Tz_Ac_OverCurr_Fault — AC side over-current fault (hardware detection).
Cause: The combined backup-load and common-load power exceeded the inverter's AC output range, tripping the hardware over-current protection.
How to fix it
- 1Check that the backup load power and common load power are within range, restart, and check whether operation is normal.
- 2Seek help from Deye if it does not recover.
Source: gb-s12k-eu-gb-s15k-eugb-s20k-eu-gb-s15k-eu-gb-s20k-eu-manual.pdf, p.49 · gb-s5k-eu-gb-s20k-eu-datasheet.pdf, p.44
Also applies to:GB-A
What it means
ALARM_ID_HEAT_OVER_TEMP_LEV_2 — The heating film temperature is too high.
Cause: The self-heating film exceeded its temperature limit - heating stayed on too long or its sensor is misreading.
How to fix it
- 1Switch off and let the system cool.
- 2If the fault returns when heating engages, contact Deye support.
Source: gb-a-pack6-gb-a4-gb-a10-gb-a16-manual.pdf, p.13