08Fault

DEYE inverter error 08 (F008)

GFDI grounding touch failure

Also displayed as F008 / F08 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+3

What it means

GFDI grounding touch failureThe GFDI circuit reports a failed grounding contact. The manual notes this code has hardly ever appeared in the field.

Cause: The GFDI circuit detected a failed ground contact, so the ground-fault protection path is not intact.

How to fix it

Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.61 · 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.50 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.50

Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7

What it means

GFDI grounding touch failureThe GFDI circuit reports a failed grounding contact.

Cause: The GFDI circuit detected a failed ground contact, so the ground-fault protection path is not intact.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or the manufacturer's customer service.

Source: 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.60 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.60 · 060_BManual_SUN-60_70_75K-G01P3-EU-AM8-LV_20260701_en_f559aeec.pdf, p.60 · +1 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27

What it means

GFDI grounding touch failureThe GFDI circuit reports a grounding-contact failure.

Cause: Bad contact in the GFDI grounding path prevents the ground-fault protection from working properly.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or manufacturer customer service.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.56

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+36

What it means

GFDI grounding touch failureThe GFDI circuit reports a grounding-contact failure.

Cause: Bad contact in the GFDI grounding path prevents the ground-fault protection from working properly.

How to fix it

Deye states this code has hardly ever appeared in the field; contact your installer or Deye service if it occurs.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.52 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.56

Also applies to:SUN-3.6K-SG05LP1-EU-SM2-PSUN-5K-SG05LP1-EU-SM2-PSUN-6K-SG05LP1-EU-SM2-PSUN-7K-SG05LP1-EU-SM2-PSUN-7.6K-SG05LP1-EU-SM2-PSUN-8K-SG05LP1-EU-SM2-PSUN-10K-SG05LP1-EU-SM2-PSUN-7.6K-SG01LP1-EU+21

What it means

GFDI_Relay_FailureGround fault detector/interrupter (GFDI) relay failure.

Cause: In a split-phase (120/240Vac) or three-phase (120/208Vac) system the backup load port N line is not connected to ground, so the GFDI relay check fails.

How to fix it

  1. When the inverter is in a split-phase (120/240Vac) or three-phase (120/208Vac) system, connect the backup load port N line to ground.
  2. If the fault still exists, contact Deye for help.

Source: 039_BManual_SUN-3.6_5_6_7_7.6_8_10K-SG05LP1-EU-SM2-P_20260428_en_70c401a6.pdf, p.49 · 043_BManual_SUN-12_14_16K-SG01LP1-EU_20260519_en_703e15ac.pdf, p.45 · 052_BManual_SUN-_3.6-6_K-OG01LP1-EU-AM2_20260406_en_dc31b173.pdf, p.45 · +4 more official manuals

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

DC/DC Converter 2 Start FailureDCDC2_START_Failure - the BUS voltage cannot be reached by PV or battery.

Cause: DC/DC converter 2 failed to start because the internal BUS voltage could not be built up from the PV or battery input.

How to fix it

Switch off the DC switches and restart the inverter.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.49 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.50 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.50

Also applies to:SUN-5K-SG02LP2-US-AM2SUN-6K-SG02LP2-US-AM2SUN-7.6K-SG02LP2-US-AM2SUN-8K-SG02LP2-US-AM2SUN-10K-SG02LP2-US-AM3SUN-12K-SG02LP2-US-AM3

What it means

GFDI Relay FailureGFDI_Relay_Failure - ground fault detector/interrupter relay fault.

Cause: In a split-phase (120/240Vac) or three-phase (120/208Vac) system, the backup load port N line is not connected to ground, so the GFDI relay check fails.

How to fix it

  1. In a split-phase (120/240Vac) or three-phase (120/208Vac) system, connect the backup load port N line to ground
  2. If the fault still exists, contact us for help.

Source: 059_BManual_SUN-5_6_7.6_8_10_12K-SG02LP2-US-AM2_AM3_20260406_en_fb6a30c7.pdf, p.54

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Cell under temperatureCell temperature fell below the protection limit; charging is inhibited until the pack warms up.

Cause: The battery is in an environment colder than its rated charge/discharge temperature window.

How to fix it

Warm the installation space and wait for the battery to return to its operating temperature range; charging resumes once the cells are warm enough.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_OVER_DIFF_TEMP_LEV_2Excessive temperature differences across the pack.

Cause: The temperature gap between measurement points exceeded the level-2 threshold - uneven heating/cooling of the cabinet or a drifting sensor.

How to fix it

  1. Check the battery is evenly ventilated and not partially exposed to a heat source; let temperatures equalize.
  2. If the code returns, contact Deye support.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.12

Frequently asked questions

What does error 08 mean on a DEYE inverter?
It depends on the model — 12 devices use code 08. On the SUN G01P3-EU-BM8 Series it means: GFDI grounding touch failure. The card for each model on this page gives its exact meaning and fix.
Is error 08 a fault or a warning?
08 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 08?
Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code. The exact steps for each affected model are listed on this page.