06Fault

DEYE inverter error 06 (F006)

Write the memory error

Also displayed as F006 / F06 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+3

What it means

Write the memory errorFailure in writing the internal memory (EEPROM).

Cause: The controller failed to write data to the EEPROM memory chip.

How to fix it

Restart the inverter; if the fault still exists, contact your installer or Deye service.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.61 · 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.50 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.50

Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7

What it means

Write the memory errorFailure in writing the internal memory (EEPROM).

Cause: The controller failed to write data to the EEPROM memory chip.

How to fix it

Restart the inverter; if the fault still exists, contact your installer.

Source: 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.60 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.60 · 060_BManual_SUN-60_70_75K-G01P3-EU-AM8-LV_20260701_en_f559aeec.pdf, p.60 · +1 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+71

What it means

Write the memory errorFailure in writing the internal memory (EEPROM).

Cause: The controller could not write data to the EEPROM memory chip.

How to fix it

Restart the inverter; if the fault still exists, contact your installer or Deye service.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.56 · 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.52 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.56

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

EEPROM Write FailureEEPROM_Write_Failure - the controller failed to write data to the EEPROM memory.

Cause: The inverter control board could not write settings to the EEPROM memory.

How to fix it

Restart the inverter 3 times and restore the factory settings.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.49 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.50 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.50

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Discharge over currentDischarge current exceeded the battery's over-current protection limit and discharging was interrupted.

Cause: Load or inverter demand exceeded the battery's rated discharge current, or a surge (e.g. motor/compressor start) tripped the protection.

How to fix it

  1. Reduce the connected load or the inverter's discharge-current limit.
  2. After the BMS recovers, confirm the steady load is within the battery's rating.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_DSG_LOW_TEMP_LEV_2The discharge temperature is too low.

Cause: Cell temperature is below the minimum discharging temperature - the battery environment is colder than the rated discharge window.

How to fix it

Warm the installation space and wait for the cells to return to the operating temperature range.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.12

Frequently asked questions

What does error 06 mean on a DEYE inverter?
It depends on the model — 10 devices use code 06. On the SUN G01P3-EU-BM8 Series it means: Write the memory error. The card for each model on this page gives its exact meaning and fix.
Is error 06 a fault or a warning?
06 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 06?
Restart the inverter; if the fault still exists, contact your installer or Deye service. The exact steps for each affected model are listed on this page.