32Fault

DEYE inverter error 32 (F032)

Inverter 2 dc high fault

Also displayed as F032 / F32 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+3

What it means

Inverter 2 dc high faultThe DC component on inverter bridge 2 is too high. The manual notes this code has hardly ever appeared in the field.

Cause: The DC component measured on inverter bridge 2 is too high.

How to fix it

Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.62 · 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.52 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.52

Also applies to:SUN-60K-G03SUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03SUN-60K-G01P3-EU-AM8-LV+7

What it means

Inverter 2 dc high faultThe DC component on inverter bridge 2 is too high.

Cause: The DC component measured on inverter bridge 2 is too high.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or the manufacturer's customer service.

Source: 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.62 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.61 · 060_BManual_SUN-60_70_75K-G01P3-EU-AM8-LV_20260701_en_f559aeec.pdf, p.61 · +1 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+27

What it means

Inverter 2 dc high faultInverter power stage 2 measured an excessively high DC component.

Cause: The DC component measured on inverter power stage 2 exceeded its limit.

How to fix it

Restart the inverter; if the fault is not ruled out, contact the installer or manufacturer customer service.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.58

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+36

What it means

Inverter 2 dc high faultInverter power stage 2 measured an excessively high DC component.

Cause: The DC component measured on inverter power stage 2 exceeded its limit.

How to fix it

Deye states this code has hardly ever appeared in the field; contact your installer or Deye service if it occurs.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.54 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.57

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

DC Injection Overcurrent (M2)DCIOver_M2_Fault - the DC component of the output current exceeded the limit (measurement channel M2).

Cause: The DC injection (DC component) in the AC output measured on channel M2 exceeded the limit.

How to fix it

Restart the inverter 3 times and restore the factory settings.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.50 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.51 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.51

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Master address repeatTwo batteries on the communication bus are using the same (master) address.

Cause: In a multi-battery bank, more than one battery is set to the same address, so two units try to act as master on the bus.

How to fix it

Set a unique address on each battery (one master, the rest slaves) per the parallel-connection instructions, then power-cycle the bank.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_PCS_RS485_COMM_ERRORThe PCS RS485 communication is abnormal.

Cause: The RS485 link between battery and PCS is delivering corrupted or intermittent data - wiring, termination, or interface fault.

How to fix it

  1. Check the RS485 cabling, pin order and terminations between battery and PCS; restart both units.
  2. Contact Deye support if it persists.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.14

Frequently asked questions

What does error 32 mean on a DEYE inverter?
It depends on the model — 10 devices use code 32. On the SUN G01P3-EU-BM8 Series it means: Inverter 2 dc high fault. The card for each model on this page gives its exact meaning and fix.
Is error 32 a fault or a warning?
32 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 32?
Restart the inverter; if the code persists after the restart, contact your installer or Deye service and provide the inverter serial number, the installation date and the displayed error code. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.