45Fault

DEYE inverter error 45 (F045)

AC Line U,V over voltage

Also displayed as F045 / F45 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-60K-G03SUN-70K-G03SUN-75K-G03+12

What it means

AC Line U,V over voltageThe U-V line voltage is above the protection setting.

Cause: The line voltage between phases U and V exceeds the protection setting; an AC cable that is too thin raises the voltage at the inverter terminals under feed-in.

How to fix it

  1. Check the AC voltage protection setting, and check if the AC cable is too thin.
  2. Check the voltage difference between the LCD and a meter.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.63 · 033_BManual_SUN-70_75_80_90_100_110K-G03_20260702_en_a9db1e1b.pdf, p.63 · 042_BManual_SUN-120_125_130_135_136K-G01P3-EU-AM8_20260702_en_05f936e3.pdf, p.62 · +2 more official manuals

SUN G02P1-EU Series

InverterFault

Also applies to:SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2SUN-9K-G02P1-EU-AM2SUN-10K-G02P1-EU-AM2SUN-10.5K-G02P1-EU-AM2

What it means

AC Line U,V over voltageThe U-V line voltage is above the protection setting. Marked 'Not available' in the manual for these models.

Cause: Line voltage protection between phases U and V - a three-phase measurement that is not used on these single-phase models.

How to fix it

  1. Marked 'Not available' in the manual - this code is not used on these models.
  2. If it is displayed nonetheless, restart the inverter and contact your installer or Deye service.

Source: 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.52 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.52

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+48

What it means

AC Line U,V over voltageThe line voltage between phases U and V is above the protection setting.

Cause: Grid U-V line voltage above the protection setting, or an AC cable that is too thin causing extra voltage rise at the inverter terminals.

How to fix it

Check the AC voltage protection setting; check if the AC cable is too thin; check the voltage difference between the LCD and a meter.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.58 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.58

Also applies to:SUN-1K-G04P1-EU-AM1SUN-1.5K-G04P1-EU-AM1SUN-2K-G04P1-EU-AM1SUN-2.2K-G04P1-EU-AM1SUN-2.5K-G04P1-EU-AM1SUN-2.7K-G04P1-EU-AM1SUN-3K-G04P1-EU-AM1SUN-3.3K-G04P1-EU-AM1+15

What it means

AC Line U,V over voltageLine over-voltage protection for the U-V pair (marked 'Not available' on single-phase models).

Cause: Line-voltage protection for the U-V phase pair; single-phase units have no such line pair, so the code is not used.

How to fix it

Marked 'Not available' on these single-phase models - the code is not used.

Source: 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.54

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

Grid OvervoltageAC_UV_OverVolt_Fault - grid voltage out of range (too high).

Cause: The grid voltage is above the range given in the specification.

How to fix it

  1. Check that the voltage is in the range of the specification
  2. Check whether the AC cables are firmly and correctly connected.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.51 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.52 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.52

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Cur Limit Mos AdhesionThe current-limiting MOSFET is stuck conducting (contact adhesion).

Cause: The BMS self-test found the current-limit MOSFET permanently conducting - a hardware failure in the current-limiting circuit.

How to fix it

Switch the battery off and contact Deye support; the current-limit circuit needs repair.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_EEPROM_ERRORThe EEPROM storage is faulty.

Cause: The BMS could not read or write its non-volatile memory holding calibration and configuration.

How to fix it

  1. Restart the system.
  2. If the fault persists, contact Deye support for BMS repair or replacement.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.14

Frequently asked questions

What does error 45 mean on a DEYE inverter?
It depends on the model — 10 devices use code 45. On the SUN G01P3-EU-BM8 Series it means: AC Line U,V over voltage. The card for each model on this page gives its exact meaning and fix.
Is error 45 a fault or a warning?
45 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 45?
Check the AC voltage protection setting, and check if the AC cable is too thin. Check the voltage difference between the LCD and a meter. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.