DEYE inverter error 47 (F047)

AC Over frequency

Also displayed as F047 / F47 on some models.

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Also applies to:SUN-120K-G01P3-EU-BM8SUN-125K-G01P3-EU-BM8SUN-130K-G01P3-EU-BM8SUN-135K-G01P3-EU-BM8SUN-136K-G01P3-EU-BM8SUN-7K-G02P1-EU-AM2SUN-7.5K-G02P1-EU-AM2SUN-8K-G02P1-EU-AM2+18

What it means

AC Over frequencyThe grid frequency is above the protection setting.

Cause: The measured grid frequency is above the configured protection limit.

How to fix it

Check the frequency protection setting.

Source: 041_BManual_SUN-120_125_130_135_136K-G01P3-EU-BM8_20251021_en_a2166559.pdf, p.63 · 065_BManual_SUN-7_7.5_8K-G02P1-EU-AM2_20260625_en_4466f08b.pdf, p.52 · 032_BManual_SUN-9_10_10.5K-G02P1-EU-AM2_20260625_en_df0f2106.pdf, p.52 · +4 more official manuals

Also applies to:SUN-6K-G06-LV-P1SUN-8K-G06-LV-P1SUN-6K-G06P3-EU-BM2-LV-P1SUN-8K-G06P3-EU-BM2-LV-P1SUN-10K-G05-LVSUN-12K-G05-LVSUN-15K-G05-LVSUN-15K-G06P3-EU-BM2-P1+71

What it means

AC Over frequencyThe grid frequency is above the protection setting.

Cause: Grid frequency measured above the configured over-frequency protection limit.

How to fix it

Check the frequency protection setting.

Source: 063_BManual_SUN-6K-G06-LV-P1_20250923_en_30a96699.pdf, p.58 · 031_BManual_SUN-1_1.5_2_2.2_2.5_2.7_3_3.3_3.6_4K-G04P1-EU-AM1_20260624_en_15adc00c.pdf, p.54 · 036_BManual_SUN-3_4_5_6_7_8_9_10_12_15K-G06P3-EU-BM2_20250506_en_0eb78440.pdf, p.58

Also applies to:SUN-3.6K-SG05LP1-EU-SM2-PSUN-5K-SG05LP1-EU-SM2-PSUN-6K-SG05LP1-EU-SM2-PSUN-7K-SG05LP1-EU-SM2-PSUN-7.6K-SG05LP1-EU-SM2-PSUN-8K-SG05LP1-EU-SM2-PSUN-10K-SG05LP1-EU-SM2-PSUN-7.6K-SG01LP1-EU+21

What it means

AC over frequencyGrid frequency out of range: the AC frequency is too high.

Cause: The grid frequency is above the range in the specification, or the AC cables are not firmly and correctly connected.

How to fix it

  1. Check that the frequency is in the range of the specification and that the AC cables are firmly and correctly connected.
  2. Seek help from Deye if the inverter cannot go back to the normal state.

Source: 039_BManual_SUN-3.6_5_6_7_7.6_8_10K-SG05LP1-EU-SM2-P_20260428_en_70c401a6.pdf, p.50 · 043_BManual_SUN-12_14_16K-SG01LP1-EU_20260519_en_703e15ac.pdf, p.46 · 052_BManual_SUN-_3.6-6_K-OG01LP1-EU-AM2_20260406_en_dc31b173.pdf, p.46 · +4 more official manuals

Also applies to:SUN-5K-SG01HP3-EU-AM2SUN-6K-SG01HP3-EU-AM2SUN-8K-SG01HP3-EU-AM2SUN-10K-SG01HP3-EU-AM2SUN-12K-SG01HP3-EU-AM2SUN-15K-SG01HP3-EU-AM2SUN-20K-SG01HP3-EU-AM2SUN-25K-SG01HP3-EU-AM2+9

What it means

Grid OverfrequencyAC_OverFreq_Fault - grid frequency out of range (too high).

Cause: The grid frequency is above the range given in the specification.

How to fix it

  1. Check whether the frequency is in the range of the specification
  2. Check whether the AC cables are firmly and correctly connected.

Source: 037_BManual_SUN-5_6_8_10_12_15_20_25K-SG01HP3-EU-AM2_20260224_en_9ef2717c.pdf, p.51 · 050_BManual_SUN-29.9_30_35_40_50K-SG01HP3-EU-BM3_4_20260224_en_544e1b2f.pdf, p.52 · 062_BManual__SUN-60_70_75_80K-SG02HP3-EU-EM6_20260224_en_38cbc9f6.pdf, p.52

Also applies to:SUN-5K-SG02LP2-US-AM2SUN-6K-SG02LP2-US-AM2SUN-7.6K-SG02LP2-US-AM2SUN-8K-SG02LP2-US-AM2SUN-10K-SG02LP2-US-AM3SUN-12K-SG02LP2-US-AM3SUN-5K-SG04LP3-EUSUN-6K-SG04LP3-EU+15

What it means

AC OverfrequencyAC over frequency - grid frequency out of range (too high).

Cause: The grid frequency is above the range given in the specification.

How to fix it

  1. Check whether the frequency is in the range of the specification
  2. Check whether the AC cables are firmly and correctly connected
  3. Seek help from us if it cannot go back to the normal state.

Source: 059_BManual_SUN-5_6_7.6_8_10_12K-SG02LP2-US-AM2_AM3_20260406_en_fb6a30c7.pdf, p.55 · 038_BManual_SUN-5_6_8_10_12K-SG04LP3-EU_20260319_en_081932c1.pdf, p.47 · 040_BManual_SUN-3_4_5_6_8_10_12K-SG05LP3-EU-SM2_20260319_en_b0183b7d.pdf, p.47 · +1 more official manuals

AI-W5.1 ESS

Energy storage systemFault

Also applies to:AI-W5.1-5P3-EU-B-ESSAI-W5.1-6P3-EU-B-ESSAI-W5.1-8P3-EU-B-ESSAI-W5.1-10P3-EU-B-ESSAI-W5.1-12P3-EU-B-ESS

What it means

AC over frequencyGrid frequency out of range (too high).

Cause: The grid frequency is above the range configured in the specification, or the AC cables are loose/incorrectly connected.

How to fix it

  1. Check that the grid frequency is within the specified range and that the AC cables are firmly and correctly connected.
  2. Seek help from Deye if it does not recover.

Source: 002_Download_4e90fe7a.pdf, p.48

GB-SL / GB-SL Pro ESS

Energy storage systemFault

Also applies to:GB-SL5K-EUGB-SL6K-EUGB-SL8K-EUGB-SL10K-EUGB-SL12K-EUGB-SL15K-EUGB-SL20K-EUGB-SL Pro 5K-EU+6

What it means

AC_OverFreq_FaultGrid frequency out of range (too high).

Cause: The grid frequency is above the range configured in the specification, or the AC cables are loose/incorrectly connected.

How to fix it

  1. Check that the grid frequency is within the specified range and that the AC cables are firmly and correctly connected.
  2. Seek help from Deye if it does not recover.

Source: 081_deye_gb_sl_pro_user_manual_46fa941a.pdf, p.50 · 010_Download_cc05df18.pdf, p.45

Also applies to:RW-L2.5ARW-L5.1RW-L10.2RW-F16SE-F5SE-F5 PlusSE-F5 ProSE-F12+7

What it means

Heat Mos adhesionThe heating-circuit MOSFET is stuck conducting.

Cause: The MOSFET that switches the heating film failed closed, so heating can no longer be switched off reliably.

How to fix it

Switch the battery off to prevent uncontrolled heating and contact Deye support.

Source: 093_Deye_RW-L2.5A_User_Manual_EN_89188fb8.pdf, p.10 · 019_Download_4a609b7e.pdf, p.10 · 021_Download_f81ba1e7.pdf, p.10 · +6 more official manuals

GB-A HV Battery

BatteryFault

Also applies to:GB-A

What it means

ALARM_ID_CHG_VOLT_LOWThe charging voltage is too low.

Cause: The voltage supplied by the charger/PCS is below what the pack needs to charge - wrong PCS charge settings or a sagging DC bus.

How to fix it

Check and correct the PCS charge-voltage settings for this battery configuration, then restart charging.

Source: 008_deye_ess_user_manual_gb_a_jpnen_v02_20250829_3fea617e.pdf, p.14

Frequently asked questions

What does error 47 mean on a DEYE inverter?
It depends on the model — 15 devices use code 47. On the SUN G01P3-EU-BM8 Series it means: AC Over frequency. The card for each model on this page gives its exact meaning and fix.
Is error 47 a fault or a warning?
47 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 47?
Check the frequency protection setting. The exact steps for each affected model are listed on this page.

Related error codes

Prefer the full written guide? Read the complete DEYE inverter error-code guide

Compiled from official DEYE user manuals. Always consult your device manual and a qualified technician before performing repairs.